For very low speed and high power applications the best suited ac motor is:

1 Answer

Answer :

For very low speed and high power applications the best suited ac motor is: synchronous motor

Related questions

Description : The most suitable servomotor for low power applications is (A) a dc series motor. (B) a dc shunt motor. (C) an ac two-phase induction motor. (D) an ac series motor.

Last Answer : (B) a dc shunt motor.

Description : A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be

Last Answer : Leading

Last Answer : Induction motor is a AC motor it is also known as asynchronous motor .

Description : AC motor

Last Answer : AC motor AC motor have two types one is Induction motor and second is synchronous motor. Induction motor have two types one is single phase induction motor and second is three phase ... self starting motor so using  external motor or we have to start it as induction motor.

Description : Needle bearing a roller bearing having a number of smaller diameter roller is well suited to a) Application involving oscillating motion b) Exceptionally high load capacity application at low peripheral speed c) Both (a) and (b) d) None of the above

Last Answer : c) Both (a) and (b)

Description : At which time power factor of the induction motor is low?

Last Answer : The power factor of the inducction motor is low at the time of starting as compare to while the induction motor is running.

Description : To reverse the direction of rotation of a three-phase AC induction motor, do one of the following: w) reverse any two of the three-phase connections x) change the frequency of the applied AC power y) operate the motor below the stall torque at very high slip z) none of the above

Last Answer : ANSWER: W -- REVERSE ANY TWO OF THE THREE-PHASE CONNECTIONS 

Description : A power tiller is most suited for rotary cultivation because: A. It generates negative draft B. Its traction requirements are low C. It provides high degree of soil pulverization D. All of the above

Last Answer : D. All of the above

Description : State the modification to be done in dc series motor to work satisfactorily as ac series motor. State applications of ac series motor.

Last Answer : Modifications are necessary in a dc series motor so that it operates satisfactorily on ac supply. The modifications are as follows:  1) AC series motor is built with a few field turns as ... and grinders 5) High speed vacuum cleaners 6) Sewing machines 7) Food processors 8) Drilling machine 

Description : For a 1.8o, 2-phase bipolar stepper motor, the stepping rate is 100 steps/second. The rotational speed of the motor in rpm is  (A) 15 (B) 30 (C) 60 (D) 90

Last Answer : For a 1.8o, 2-phase bipolar stepper motor, the stepping rate is 100 steps/second. The rotational speed of the motor in rpm is 30 

Description : The torque speed characteristic of a repulsion motor resembles which of the following d.c. motor characteristics  A) Separately excited B) Shunt C) Series D) Compound

Last Answer : The torque speed characteristic of a repulsion motor resembles which of the following d.c. motor characteristics Series 

Description : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be

Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Description : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque  (1) Decreases (2) Increases (3) Remains constant (4) None of the above

Last Answer : The speed of a three-phase induction motor is controlled by variable voltage variable frequency control (i.e. keeping V/f constant). As the frequency is reduced, the slip at maximum torque Increases 

Description : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min (A) 100 rpm (B) 200 rpm (C) 400 rpm (D) 800 rpm

Last Answer : The speed of a 2-pole, 3-phase stepper motor operated by 1200 pulses/min 200 rpm

Description : A 3-phase, 4-pole, 50Hz induction motor runs at a speed of 1440 rpm. The rotating field produced by the rotor rotates at a speed of ________ rpm with respect to stator field. (A) 1500 (B) 0 (C) 1440 (D) 60

Last Answer : 0

Description : In a 3-phase slip-ring induction motor, the slip at some speed is 0.05. The speed is reduced by inserting an external resistance in the rotor circuit and the slip is 0.15. If the rotor winding resistance per phase is 0.2 Ω, the external resistance is (A) 0.2 Ω (B) 0.3 Ω (C) 0.4 Ω (D) 0.5 Ω

Last Answer : In a 3-phase slip-ring induction motor, the slip at some speed is 0.05. The speed is reduced by inserting an external resistance in the rotor circuit and the slip is 0.15. If the rotor winding resistance per phase is 0.2 Ω, the external resistance is 0.3 Ω

Last Answer : In variable speed motor a weaker commutating field is needed at low speed than at high speed.

Last Answer : Series motor has the poorest speed control.

Description : The speed of a D.C. motor can be controlled by varying  1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above

Last Answer : The speed of a D.C. motor can be controlled by varying  1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above

Last Answer : In case the back e.m.f. and the speed of a D.C. motor are doubled, the torque developed by the motor will remain unchanged.

Last Answer : The speed of a D.C. shunt motor can be increased by increasing the resistance in field circuit.

Last Answer : As the load is increased the speed of D.C. shunt motor will reduce slightly.

Last Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

Last Answer : The speed of a D.C. series motor is inversely proportional to the armature current.

Last Answer : In a D.C. shunt motor, speed is independent of armature current.

Last Answer : The speed of a D.C. shunt motor more than its full-load speed can be obtained by decreasing the field current.

Last Answer : The speed of a universal motor is usually reduced by using gearing.

Last Answer : Speed control of a universal motor is achieved by varying field flux with tapped field windings, connecting rheostat in series, applying variable voltage by means of silicon controlled rectifier, applying variable voltage by means of variable auto-transformer.

Last Answer : In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will run as induction motor.

Last Answer : Centrifugal switch disconnects the auxiliary winding of the motor at about 70 to 80 percent of synchronous speed.

Last Answer : The speed/load characteristics of a universal motor is same as that of D.C. series motor.

Last Answer : Speed torque characteristic of a repulsion induction motor is similar to that of a D.C. compound motor.

Last Answer : If the centrifugal switch does not open at 70 to 80 percent of synchronous speed of motor, it would result in damage to the starting winding.

Last Answer : The speed control of universal motor used for sewing machines is by varying the resistance.

Description : What are the speed control methods of dc motor?

Last Answer : Field control of DC motor Armature control of DC motor

Description : speed control methods of three phase induction motor?

Last Answer : Speed control of three phase induction motor

Description : Which of the following communications lines is best suited to interactive processing applications? a. narrow band channel b. simplex lines c. full duplex lines d. mixed band channels

Last Answer : full duplex lines

Description : The most practical method of controlling the RPM of a step-speed AC motor is to _____________. A. change input voltage B. vary the number of poles C. vary power factor D. change the number of brushes

Last Answer : Answer: B

Description : Transformers are used onboard ships with AC generators to _____________. A. change frequency B. increase power output to modulating frequency controllers C. decrease power output to modulating frequency ... D. permit higher voltage for electric motor operation and low voltage for lighting circuits

Last Answer : Answer: D

Description : The most suitable motor for low power applications is a/an:  (A) dc series motor (B) dc shunt motor (C) ac two-phase induction motor (D) ac series motor

Last Answer : The most suitable motor for low power applications is a/an: dc shunt motor

Description : A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the ... the motor will be (A) 23.06 kW (B) 24.11 kW (C) 25.01 kW (D) 26.21 kW

Last Answer : A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the core losses are 1200 W. The air-gap power of the motor will be 25.01 kW

Description : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is (A) 0.25 pu (B) 0.5 pu (C) 1.0 pu (D) 1.5 pu

Last Answer : The maximum reluctance power of a salient-pole synchronous motor having direct-axis reactance, 1.0 pu and quadrature-axis reactance, 0.5 pu, and input voltage, 1.0 pu is 0.5 pu

Last Answer : (b) Clostridium butylicum Lipase Removal of oil stains

Last Answer : The mechanical power developed by a shunt motor will be maximum when the ratio of back e.m.f. to applied voltage is 0.5.

Last Answer : The power mentioned on the name plate of an electric motor indicates the output power available at the shaft.

Last Answer : In case the conditions for maximum power for a D.C. motor are established, the efficiency of the motor will be less than 50%.

Last Answer : In a D.C. shunt motor, under the conditions of maximum power, the current in the armature will be more than full-load current.

Last Answer : Yes, we can make the power factor of synchronous motor leading by adjusting its excitation.

Description : Silicon transistors are preferred because: (a) High operating temperature (b) Low leakage current (c) Suited to high frequency circuits (d) All

Last Answer : (d) All

Description : A series motor is best suited for driving?

Last Answer : A series motor is best suited for driving cranes and hoists.