Electrical fault between two windings of same phase of a generator having double star winding can be detected by the following protection in a generator:

1 Answer

Answer :

Electrical fault between two windings of same phase of a generator having double star winding can be detected by the following protection in a generator: inter turn fault protection

Related questions

Description : Which statement is true concerning a split-phase induction motor? A. Motor rotation can be reversed without changing the windings or leads. B. Motor speed can be readily adjusted from zero to full ... proper wiring. D. Motor rotation can be reversed by reversing the leads on the starting winding.

Last Answer : Answer: D

Description : You are testing the insulation in an AC generator with a megohmeter. The resistance value of a dry, clean winding will ____________. A. continue to rise as the test potential is maintained, ... fairly steady after 5 to 7 minutes D. stabilize after approximately 2 to 4 minutes of fluctuation

Last Answer : Answer: A

Description : The amount of voltage induced in the windings of an AC generator depends on ____________. A. the number of conductors in series per winding B. the speed at which the magnetic field passes across the winding C. the strength of the magnetic field D. all of the above

Last Answer : Answer: D

Description : Moisture absorbed in the windings or condensed on the surface of electrical machinery insulation ________. A. is good for long term preserving since most insulation is organic and contains some amount B. ... D. reduces the amount of current supplied or drawn by the machine so horsepower is limited

Last Answer : Answer: B

Description : A three phase slip ring induction motor is fed from the rotor side with stator winding short circuited stator is: (1) Slip frequency (2) Supply frequency (3) Frequency corresponding to rotor speed (4) Zero

Last Answer : A three phase slip ring induction motor is fed from the rotor side with stator winding short circuited stator is: Slip frequency

Description : A single-phase induction motor with only the main winding excited would exhibit the following response at synchronous speed  (A) Rotor current is zero (B) Rotor current is non-zero and is ... and backward rotating fields are equal (D) Forward rotating field is more than the backward rotating field

Last Answer : A single-phase induction motor with only the main winding excited would exhibit the following response at synchronous speed  (A) Rotor current is zero (B) Rotor current is non-zero and is ... backward rotating fields are equal (D) Forward rotating field is more than the backward rotating field

Last Answer : In split-phase motor auxiliary winding is of thin wire placed at the top of the slots.

Description : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be?

Last Answer : The running winding of a single phase motor on testing with meggar is found to be ground. Most probable location of the ground will be at the slot edge where coil enters or comes out of the slot.

Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Last Answer : In a split phase motor, the running winding should have low resistance and high inductance.

Description : In testing a three-phase delta winding for an open circuit using a megohmmeter, you must ______________. A. test each phase with all connections intact B. measure the voltage across the open ... groups to avoid short circuiting D. open the delta-connections to avoid shunting the phase being tested

Last Answer : Answer: D

Description : If you obtain a low resistance reading with a megohmmeter connected between terminals 'A' and 'C' of the three-phase, wye-connected winding shown in the illustration, there is __________. EL-0074 A. no open circuit ... 'B' C. an open circuit between 'A' and 'C' D. an open circuit in both windings

Last Answer : Answer: A

Description : Which of the following statements is true concerning all three-phase alternators? A. Each has three separate but identical armature windings acted on by one system of rotating magnets. B. Each has one ... The three phases always provide power to the load through three sets of slip rings and brushes.

Last Answer : Answer: A

Description : In a capacitor start single-phase induction motor, the capacitor is connected (A) in series with main winding. (B) in series with auxiliary winding. (C) in series with both the windings. (D) in parallel with auxiliary winding.

Last Answer : Ans: B To make single phase motor self start. We split the phases at 90 degree. Hence, motor behaves like a two phase motor.

Last Answer : Burning out of windings is due to short circuited capacitor.

Description : Consider the following statements: Star delta starter is used in 3-phase induction motor because it  1. Prevents heating of the motor winding  2. Ensures permissible minimum starting current  3. Is regulated by electricity ... and 4 are correct (c) 1, 3 and 4 are correct (d) 1 and 2 are correct 

Last Answer : Consider the following statements: Star delta starter is used in 3-phase induction motor because it  1. Prevents heating of the motor winding  2. Ensures permissible minimum starting current  3. Is regulated by ... and 4 are correct (c) 1, 3 and 4 are correct (d) 1 and 2 are correct 

Description : 21.The ordinary two winding transformer's primary and secondary windings always have A. different no of turns B. same size of copper wire C. a common magnetic circuit D. separate magnetic circuits

Last Answer : C. A common magnetic circuit

Description : The removal of paint from electrical equipment, such as generators, should be cautiously undertaken because ____________. A. the mechanical shock of paint removal lessens the dielectric strength ... phase windings frequently become isolated from each other due to dust interference at the terminals

Last Answer : Answer: B

Last Answer : In A.C. series motor compensating winding is employed to reduce sparking at the brushes.

Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Last Answer : In a capacitor start and run motors the function of the running capacitor in series with the auxiliary winding is to improve power factor.

Description : The steady-state fault current during a 3 phase terminal fault on a generator is limited by: (1) Transient reactance of the generator (2) Sub-transient reactance of the generator (3) Synchronous reactance of the generator (4) DC off—set during the instant of the fault

Last Answer : 1

Description : Which of the two main types of rotors can have either a single winding or three Y-connected windings?

Last Answer : The drum or wound rotor.

Description : 27] In a transformer, the leakage flux of each winding is proportional to the current in that winding because A. Ohm's law applies to magnetic circuits B. Leakage paths do no saturate C. the two windings are electrically isolated D. mutual flux is confined to the core

Last Answer : B. Leakage path do not saturate

Description : Motor name plate data includes '°°C rise'. This indicates the _____________. A. actual running temperature of the winding from no load to full load B. permissible temperature rise ... above normal full load operating temperature D. maximum allowable temperature rise for continuous no load service

Last Answer : Answer: B

Description : Basically, a magnetic amplifier is a saturable reactor with the addition of _____________. A. AC to the bias winding B. variable capacitance to all windings C. eddy current protectors D. a rectifier in the load circuit

Last Answer : Answer: D

Description : Routine maintenance of dry-type transformers should include ____________. A. cleaning the windings, if accessible, with a vacuum cleaner or very low pressure air B. measuring and recording the winding ... . making sure that the units are close to bulkheads or corners to protect them from damage

Last Answer : Answer: A

Description : Which type of winding is preferred for armature windings of alternator? Why?

Last Answer : Double layer, short pitched and distributed type of armature winding. It eliminates high frequency harmonics hence it makes induced emf more sinusoidal.

Description : A CT has 2 – secondary windings. If we use only one secondary winding can we keep the unused secondary winding short circuited?

Last Answer : No. If it is short-circuited then the ratio will not get correctly. The turns of primary winding will be shared between 2 secondary windings. So the unused secondary winding should kept open. 

Description : In a transformer, low voltage winding is placed near the core in case of concentric windings so as to  1. Reduce the leakage flux 2. Reduce the insulation requirement 3. Reduce the risk of voltage shock in case of insulation breakdown 4. Reduce the ... a) 1, 2, 3 (b) 2, 3, 4 (c) 1, 2, 3, 4 (d) 2, 3

Last Answer : In a transformer, low voltage winding is placed near the core in case of concentric windings so as to  1. Reduce the leakage flux 2. Reduce the insulation requirement 3. Reduce the risk of voltage shock in case of insulation breakdown 4. Reduce ... ) 1, 2, 3 (b) 2, 3, 4 (c) 1, 2, 3, 4 (d) 2, 3

Description : A 4-pole, 3-phase, double-layer winding is housed in a 36-slot stator for an ac machine with 60o phase spread. Coil span is 7 short pitches. Number of slots in which top and bottom layers belong to different phases is  (A) 24 (B) 18 (C) 12 (D) 0

Last Answer : A 4-pole, 3-phase, double-layer winding is housed in a 36-slot stator for an ac machine with 60o phase spread. Coil span is 7 short pitches. Number of slots in which top and bottom layers belong to different phases is 24 

Description : The type of single-phase induction motor having the highest power factor at full load is (A) shaded pole type (B) split-phase type (C) capacitor-start type (D) capacitor-run type

Last Answer : The type of single-phase induction motor having the highest power factor at full load is capacitor-run type

Description : In a single phase induction motor driving a fan load, the reason for having a high resistance rotor is to achieve (A) low starting torque (B) quick acceleration (C) high efficiency (D) reduced size

Last Answer : In a single phase induction motor driving a fan load, the reason for having a high resistance rotor is to achieve quick acceleration

Description : In preparing to take insulation resistance readings on a main generator, the windings should be grounded for about 15 minutes prior to the test to _____________. A. allow accurate zeroing of the meter ... the windings D. help the windings to cool to the same temperature as the ground test connection

Last Answer : Answer: C

Description : Will rotor earth fault relay operate for earth fault in main exciter winding or RCU Diode Bridge also? 

Last Answer : Yes. 

Description : Induction generator is stable at a: 

Last Answer : Induction generator is stable at a: speed above synchronous speed

Description : The main purpose of an electric space heater installed in a large AC generator is to _____________. A. keep the lube oil warm for quick starting B. prevent moisture from condensing in the ... is shutdown C. prevent the windings from becoming brittle D. prevent acidic pitting of the slip rings

Last Answer : Answer: B

Description : An AC generator operating in parallel loses its excitation without tripping the circuit breaker. This will __________. A. not affect the faulty generator due to the compensation of the other generators B. ... between the armature and the bus D. cause high currents to be induced in the field windings

Last Answer : Answer: D

Description : Unnecessary and frequent applications of varnish to the generator windings to repair defective insulation will result in ____________. A. heavy coatings of varnish interfering with heat dissipation B. ... of the rectifier assembly D. a built-up of varnish without changing generator operation

Last Answer : Answer: A

Description : Brushes in a generator must be positioned in the neutral plane to avoid sparking between the brushes and the _____________. A. yoke B. armature windings C. field pole windings D. commutator

Last Answer : Answer: D

Description : Which of the following statements, concerning the general maintenance of a brushless generator, is correct? A. Paint should be applied to insulating surfaces on an annual basis. B. Alcohol should be used to ... . D. Accessible generator parts should be wiped with a clean dry rag on a periodic basis.

Last Answer : Answer: D

Description : The reactive power drawn by a motor from an AC generator is the power which is _____________. A. used to establish the magnetic field of the motor B. lost in overcoming friction in the ... by current flow through the windings D. transmitted directly through the rotor shaft to perform useful work

Last Answer : Answer: A

Description : The most practical way to control the voltage output of an AC generator is to vary the _____________. A. number of windings B. speed of the rotating field C. strength of the rotating magnetic field D. power factor of the load

Last Answer : Answer: C

Description : If the driving torque, such as that produced by a diesel engine, creates pulsations when coupled with a synchronous generator operating in parallel; the generator rotor may be periodically pulled ... windings B. direct coupling C. increase governor speed droop D. decreasing governor speed droop

Last Answer : Answer: A

Description : The amount of voltage induced in the windings of an AC generator depends mainly on _____________. A. the number of field poles energized B. the speed at which the stator windings rotate through the magnetic field C. the strength of the magnetic field D. all of the above

Last Answer : Answer: C

Description : The voltage output of an AC generator is accurately controlled by _____________. A. changing the sensitivity of the prime mover to large changes in voltage B. varying the reluctance of the air gap C. varying the DC exciter voltage D. shorting out part of the armature windings

Last Answer : Answer: C

Description : The main purpose of an electric space heater installed in a large AC generator is to _____________. A. prevent the windings from becoming brittle B. prevent moisture from condensing in the windings during ... C. prevent acidic pitting of the slip rings D. keep the lube oil warm for quick starting

Last Answer : Answer: B