The steady-state fault current during a 3 phase terminal fault on a generator is limited by:

(1) Transient reactance of the generator

(2) Sub-transient reactance of the generator

(3) Synchronous reactance of the generator

(4) DC off—set during the instant of the fault

3 Answers

Answer :

The steady-state fault current during a 3 phase terminal fault on a generator is limited by: Synchronous reactance of the generator

Answer :

2

Answer :

1

Related questions

Description : at the terminal of a three-phase 6.6Kv alternator a load R=200 ohm is connected between two-phase and the third phase is opened. Z1=z2=5 ohm Zo=2 find out the fault current .

Last Answer : 32A

Description : Electrical fault between two windings of same phase of a generator having double star winding can be detected by the following protection in a generator:

Last Answer : Electrical fault between two windings of same phase of a generator having double star winding can be detected by the following protection in a generator: inter turn fault protection

Description : Which of the following is the demerit of a 'constant voltage transmission system' ? (a) Increase of short-circuit current of the system (b) Availability of steady voltage at all loads at ... of carrying increased power for a given conductor size in case of long-distance heavy power transmission

Last Answer : (a) Increase of short-circuit current of the system

Description : Which of the following is the demerit of a 'constant voltage transmission system' ? (a) Increase of short-circuit current of the system (b) Availability of steady voltage at all loads at ... of carrying increased power for a given conductor size in case of long-distance heavy power transmission

Last Answer : (a) Increase of short-circuit current of the system

Description : Moisture absorbed in the windings or condensed on the surface of electrical machinery insulation ________. A. is good for long term preserving since most insulation is organic and contains some amount B. ... D. reduces the amount of current supplied or drawn by the machine so horsepower is limited

Last Answer : Answer: B

Description : When paralleling two alternators using three synchronizing lamps, the flickering of all three lamps becomes progressively slower and slower. This means the ______________. A. frequency of the incoming ... the bus D. terminal voltage of the incoming alternator is approaching that of the bus

Last Answer : Answer: A

Description : Why earth fault current of generator should not be reduced below 5A? 

Last Answer : To limit over voltage due to neutral shift.  

Description : The zero sequence current of a generator for line to ground fault is j 2.4 p.u. The current through the neutral during the fault is (a) j 0.8 p.u (b) j 2.4 p.u. (c) j 0.24 p.u. (d) j 7.2 p.u. 

Last Answer : j7.2

Description : For a fault at the terminals of a synchronous generator, the fault current is maximum for a  A) 3-phase fault B) 3-phase to ground fault C) Line to ground fault D) Line to line fault

Last Answer : C) Line to ground fault

Description : You are testing the insulation in an AC generator with a megohmeter. The resistance value of a dry, clean winding will ____________. A. continue to rise as the test potential is maintained, ... fairly steady after 5 to 7 minutes D. stabilize after approximately 2 to 4 minutes of fluctuation

Last Answer : Answer: A

Description : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are (A) 0.5 pu ... pu, 0.5 pu (C) 0.707 pu, 0.707 pu (D) 0.5 pu, 0.5 pu

Last Answer : The power factor angle and torque angle of a salient pole synchronous generator drawing a current of 1.0 pu from a lagging load are 45o and 15o, respectively. The direct axis and quadrature axis currents, respectively, are 0.866 pu, 0.5 pu

Description : Hysteresis in a direct current generator is indicated by _____________. A. arcing at the brushes B. pulsating terminal current C. heating of the armature core D. hunting and over control

Last Answer : Answer: C

Description : The simplest method of controlling the terminal voltage of compound-wound DC generator is with a _____________. A. hand-operated field rheostat connected in series with the shunt field circuit B. ... in series with the load D. balance coil diverting neutral current through the shunt field

Last Answer : Answer: A

Description : A dc shunt generator has a speed of 800 rpm when delivering 20 A to the load at the terminal voltage of 220V. If the same machine is run as a motor it takes a line current of 20A from 220V supply. The speed of ... . (B) more than 800 rpm. (C) less than 800 rpm. (D) both higher or lower than 800 rpm.

Last Answer : (C) less than 800 rpm.

Description : As shown in the illustration, the circuit which 'shapes' the linear output of the thrust lever so that the steady-state ship speed is linear with respect to that lever's setting is the _____________. EL-0095 A. 'pitch controller' B. 'error amplifier' C. 'function generator' D. 'servo amplifier'

Last Answer : Answer: C

Description : A cylinder rotor generator delivers 0.5 pu power in the steady-state to an infinite bus through a transmission line of reactance 0.5 pu. The generator no-load voltage is 1.5 pu and the infinite bus voltage is 1 pu. The ... fault at the generator terminal is  (A) 53.5 (B) 60.2 (C) 70.8 (D) 79.6

Last Answer : A cylinder rotor generator delivers 0.5 pu power in the steady-state to an infinite bus through a transmission line of reactance 0.5 pu. The generator no-load voltage is 1.5 pu and the ... clearing angle, in degrees, for a three-phase dead short circuit fault at the generator terminal is 79.6

Description : For centrifugal pumps  (A) Initial cost is low  (B) Limited space is required  (C) The discharge obtained is steady and non-pulsating  (D) All the above 

Last Answer : (D) All the above 

Description : A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the ... the motor will be (A) 23.06 kW (B) 24.11 kW (C) 25.01 kW (D) 26.21 kW

Last Answer : A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the core losses are 1200 W. The air-gap power of the motor will be 25.01 kW

Description : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor ... Hz supply is  (A) 58.5 A (B) 45.0 A (C) 42.7 A (D) 55.6 A

Last Answer : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor is connected to a 236 , V 57 Hz supply is 45.0 A 

Description : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole)  (A) has q -axis current only (B) has d -axis current only (C) has both d and q axis currents (D) cannot be divided between q and d axis currents

Last Answer : The armature current on symmetrical 3 phase short circuit of a synchronous machine (salient pole) has d -axis current only

Description : How generator earth fault relay works? 

Last Answer : 100% earth fault relay works on the principle involving monitoring of neutral side and line side components of 3rd harmonic voltages produced by generator in service. Since the machine is grounded with ... be detected by VL3 neutral displacement module, which is tuned to find frequency.   

Description : Where fault level is more, whether in generator bus duct or UT bus duct? Why?

Last Answer : Fault level is more in UT bus duct. Because the fault currents fed by the both generator and GT adds up within UT bus duct in case there is a fault in UT bus duct. 

Description : Rain drops falling through atmospheric air attain limited terminal velocity, because of (A) Upward thrust due to air (B) Viscous force exerted by air (C) Surface tension effects of water (D) Force of gravity

Last Answer : Option B

Description : 53. While plotting constraints on a graph paper, terminal points on both the axes are connected by straight line because a. The resources are limited in supply b. The objective function as a linear function c. The constraints are linear equations or inequalities d. All of the above

Last Answer : c. The constraints are linear equations or inequalities

Description : A three-phase synchronous motor has a terminal voltage of 460 V and a terminal current of 120 A at a power factor of 0.95 lagging, synchronous reactance of 1.68 ohm and the field current is 47 A. The field to armature mutual ... _____________.      (a). 20mH   (b). 16mH   (c). 24mH   (d). 22mH

Last Answer : 22

Description : Which type of generator gives a constant voltage output at all loads?

Last Answer : Level compound generator type of generator gives a constant voltage output at all loads.

Description : The external characteristic of a shunt generator can be obtained directly from its – characteristic   1. internal 2. open-circuit 3. load-saturation 4. Performance 

Last Answer : The external characteristic of a shunt generator can be obtained directly from its open-circuit characteristic

Description : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is

Last Answer : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is 0.87

Description : A _________ is used to measure the stator % winding temperature of the generator.  (A) Thermocouple (B) Pyrometer (C) Resistance thermometer (D) Thermometer

Last Answer : A Resistance thermometer is used to measure the stator % winding temperature of the generator. 

Description : The fall in speed of a dc generator due to increase in load can be corrected by  (1) cooling the armature.. (2) increasing the excitation. (3) reducing the load voltage. (4) increasing the input to the prime mover

Last Answer : It   can  be  corrected  by  increasing  the  input  to  the  prime  mover.

Description : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading

Last Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

Description : In a DC generator the windings of interpoles are connected :  (A) in series with main field winding, to create a pole,of same polarity as the main pole ahead in the direction of rotation.  ... winding, to create a pole of opposite polarity as the main pole ahead in the direction of rotation.

Last Answer : In a DC generator the windings of interpoles are connected :  in series with the armature winding, to create a pole of same polarity as the main pole ahead in the direction of rotation. 

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Description : The armature reaction in a synchronous generator supplying leading power factor load is (A) magnetizing (B) demagnetizing (C) demagnetizing and cross-magnetizing (D) magnetizing and cross-magnetizing

Last Answer : The armature reaction in a synchronous generator supplying leading power factor load is magnetizing and cross-magnetizing

Description : What is the difference between an AC and DC generator?

Last Answer : The generator which generates DC voltage is called DC generator and generator which generates AC voltage is called AC generator (or) Alternator. In DC generator armature is rotated and field winding ... generator. A DC generator can generate low voltages but an AC generator can generate upto 11kv.

Description : What is the principle of DC generator?

Last Answer : principle

Description : From which material field coils of DC generator are made of?

Last Answer : Field coils of DC generator are usually made of copper.

Description : Why is the armature of DC generator laminated?

Last Answer : The armature of DC generator is laminated to reduce eddy current losses.

Description : What are the main parts of a generator?

Last Answer : the main parts of the generator are as follows yoke Armature Poles field winding Prime mover  Commutator Shaft Bearings Brushes

Last Answer : if induction motor rotates exceed than its synchronous speed, it acts as a generator.

Description : increases the steady state accuracy. (a) Integrator (b) Differentiator (c) Phase lead compensator (d) Phase lag compensator Ans:A 10.As a result of introduction of negative feedback which of the following will not decrease ? (a) Band width (b) Overall gain (c) Distortion (d) Instability

Last Answer : Ans: A

Description : Steady state equimolal counter diffusion occurs in case of (A) Leaching (B) Absorption (C) Binary phase distillation (D) Liquid-liquid extraction

Last Answer : (C) Binary phase distillation

Description : The relative speed between the magnetic fields of stator and rotor under steady state operation is zero for a (A) dc machine. (B) 3 phase induction machine. (C) synchronous machine. (D) single phase induction machine.

Last Answer : Ans: all options are correct

Description : What are the reason of fall of terminal voltage of a D.C.Shunt generator?

Last Answer : As the load current increases, the terminal voltage tends todrop due to increased current and drop in voltage due to internalwinding resistance.

Description : Which of the terms listed best describes a compound-wound DC generator having a higher voltage at no load than at full load? A. Flat compounded B. Over compounded C. Under compounded D. Terminal compounded

Last Answer : Answer: C

Description : A compound generator has a no-load voltage of 250 volts and a full-load voltage of 230 volts, and therefore, is considered to be _____________. A. flat compounded B. over compounded C. under compounded D. terminal compounded

Last Answer : Answer: C

Description : What are the factors, which varies terminal voltage of generator?

Last Answer : a) Voltage drop due to resistance (Ra drop). This is negligible. b) Voltage drops due to leakage reactance (XL). c) Voltage drops due to armature reaction. 

Description : Which of the following is FALSE ? (A) The grammar S ⟶ aSb|bSa|SS|∈, where S is the only non-terminal symbol and ∈ is the null string, is ambiguous. (B) SLR is powerful than LALR. (C) An LL(1) parser is a top-down parser. (D) YACC tool is an LALR(1) parser generator.

Last Answer : (B) SLR is powerful than LALR.

Description : The terminal voltage of a DC shunt generator drops on load because of all of the following except : (A) Armature reaction (B) Armature resistance drop (C) Commutation (D) Field weakening due to armature reaction and armature resistance drop

Last Answer : (D) Field weakening due to armature reaction and armature resistance drop