Description : Once the condensate reaches the _____ , it becomes available to the boiler for recycling. • Condenser • Turbine • Boiler • Generator
Last Answer : • Boiler
Description : A steam and condensate system represents a _____ loop. • Discontinuous • Continuous • None of the above • All of the above
Last Answer : • Continuous
Description : when steam is condensate volume is drastically……. a) reduces b) increase c) both a) & b) d) None of above
Last Answer : a) reduces
Description : Water that is fed back to the boiler by the pump is called? a. Absorber b. Absolute c. Compressor d. Condensate
Last Answer : d. Condensate
Description : A device known as a _______ is used to release condensate from the pipework whilst preventing the steam from escaping from the system. a. Steam traps b. Steam pipes c. Boiler nose d. Release valve
Last Answer : a. Steam traps
Description : Condensate is the liquid formed when steam passes from the ________ to the ______ state. a. Vapor, solid b. Solid, liquid c. Vapor, liquid d. None
Last Answer : c. Vapor, liquid
Description : The back pressure created by lift is approximately ______PSIG for every 2 feet of condensate lift. a. 1 PSIG b. 3PSIG c. 1PSGI d. 3PSGI
Last Answer : a. 1 PSIG
Description : The _______ system includes anywhere that the steam condenses to form liquid water. a. Loop b. Power c. Liquid d. Condensate
Description : A __________ is a type of heat exchange system where water is heated to its' boiling point via combustion of a fuel blown through a tube submerged in water. a. Condensate loop b. Hyperbolic cooling tower c. Steam boiler d. All of above
Last Answer : c. Steam boiler
Description : Which cooling Towers use a process similar to the one found in small evaporation active cooling units a) hyperbolic b) Tower c) condensate loop d) none of these
Last Answer : a) hyperbolic
Description : ____________is used to release condensate in pipe work a) steam trap b) valves c) power generators d) none of above
Last Answer : b) valves
Description : In a gas-liquid shell and tube heat exchanger, the (A) Presence of a non-condensable gas decreases the condensing film coefficient (B) Gases under high pressure are routed through the tube side, because high pressure ... water or steam condensate remain localised to the tubes (D) All 'a', 'b' & 'c'
Last Answer : (D) All 'a', 'b' & 'c'
Description : Condensing film co-efficient for steam on horizontal tubes ranges from 5000 to 15000 Kcal/hr.m2 .°C. Condensation of vapor is carried out inside the tube in a shell and tube heat ... drop through the exchanger is desired (D) Temperature of the incoming vapor is very high
Last Answer : (B) Supersaturated
Description : When gas changes to liquid through the process of condensation, the temperature A] Increases. B] Decreases C] Remains constant. D] None of the mentioned
Last Answer : C] Remains constant.
Description : Adiabatic process is (A) Essentially an isentropic process is___________ (B) Non-heat transfer process (C) Reversible process (D) Constant temperature process
Last Answer : (B) Non-heat transfer process
Description : Find false statement about effect of sulphur in fuel? (A) It has heating value (B) It helps in electrostatic precipitation of ash in flue gases (C) It leads to corrosion of air heaters, ducting, etc. if flue gas exit temperature is low (D) It erodes furnace walls
Last Answer : (D) It erodes furnace walls
Description : The relative heat absorption for successively added equal areas of boiler convection heating surfaces__________ (A) Increases (B) Decreases (C) Remain unaffected (D) First increases and then decreases
Last Answer : (B) Decreases
Description : An economiser in a boiler........ A]Increases steam pressure. B]Increases steam flow C]Decreases fuel consumption D]Decreases steam pressure
Last Answer : C]Decreases fuel consumption
Description : The efficiency of the plant _____ with the mechanical draught a) Increases b) Decreases c) Remain constant d) None of the above
Last Answer : a) Increases
Description : Which of the following option is incorrect about the sludges? a) Sludges are soft, loose and slimy precipitate b) They are non-adherent deposits and can be easily removed c) Formed generally at heated portions of the boiler d) Can be removed by blow down operation
Last Answer : c) Formed generally at heated portions of the boiler
Description : In a steam condenser, the partial pressure of steam and air are 0.06 bar and 0.007 bar respectively. The condenser pressure is (A) 0.007 bar (B) 0.053 bar (C) 0.06 bar (D) 0.067 bar
Last Answer : (D) 0.067 bar
Description : Green coal, in order to be burnt, must be (A) Heated sufficiently (B) Burnt in excess air (C) Heated to its ignition point (D) Burnt as powder
Last Answer : (C) Heated to its ignition point
Description : Combustion is the ideal air/fuel ratio where a. the mixing proportion is correct, b. the fuel is completely burned c. the oxygen is entirely consumed d. All of the above
Last Answer : d. All of the above
Description : Based on the exhaust gas analysis, a controller maintains stoichiometric combustion __ a. by commanding a servo motor to adjust the combustion air damper b. By commanding servo motor to adjust the fuel supply valve. c. Both a. & b. d. None of the above.
Last Answer : c. Both a. & b.
Description : Detecting and monitoring carbon monoxide assures the air/fuel ratio is not too rich as a. The excess air is trimmed b. Excess air is let out c. Both a. & b. d. None of above
Last Answer : a. The excess air is trimmed
Description : It is easy to detect and monitor excess air a. As oxygen not used for combustion is heated and discharged with the exhaust gases. b. Oxygen is discharged without heating c. Both a. & b. d. None of above
Last Answer : a. As oxygen not used for combustion is heated and discharged with the exhaust gases.
Description : Oxygen trim control strategy __ a. continuously measures the oxygen content in the flue gas b. adjusts the combustion air flow c. Continually tuning the air-fuel mixture. d. All of above
Last Answer : d. All of above
Description : Use of ______ is prohibited in process boilers. a. Use of a common gas b. combustion air control linkage c. jack shaft d. All of the above
Description : For process boilers , combustion air fans must meet the following requirements ___ a. The fan motor shall be driven by a variable speed drive b. The fan motor shall include controls that limit the fan motor demand to no more than 30 %. c. Both a. & b. d. None of the above
Description : A flue damper and a vent damper are two examples of _______ a. Combustion air positive shut off devices b. Combustion air negative shut off devices c. Both a. & b. d. None of the above
Last Answer : a. Combustion air positive shut off devices
Description : Combustion air positive shut-off shall be provided on all newly installed _______ a. Grant boilers b. Process boilers c. Worcester boilers d. All of the above
Last Answer : b. Process boilers
Description : Which of these is an output of a ‘Furnace’? a. Fuel gas b. Cool Air c. Flue gases d. Water Vapor
Last Answer : c. Flue gases
Description : What is the function of boiler? • To burn the fuel in a confined closed system With the supply of air • To generate steam in varying pressure • To generate steam at constant pressure • To produce flue gases by burning fuel at a given pressure
Last Answer : • To generate steam at constant pressure
Description : What is the reason to service a cooling tower? a) to ensure proper air flow b) to clean the tubes c) to inspect the water pump d) all of these
Last Answer : all of these
Description : When the bubbles of steam are produced? • Once the water reaches saturation temperature • Once the water starts evaporating • Once the temperature decreases • None of the above
Last Answer : • Once the water reaches saturation temperature
Description : Direct relation between…….. &………of saturated steam, the amount of energy input to process easy to control. a) volume, pressure b) volume, temperature c) temperature, pressure d) None of above
Last Answer : c) temperature, pressure
Description : Feed water usually at…… °C temperature. a) 70 b) 120 c) 1000 d) 80
Last Answer : d) 80
Description : The product of efficiency & heat transferred to the working fluid is? a. Net temperature change b. Net work done c. Net enthalpy change d. None of the mentioned
Last Answer : b. Net work done
Description : What is the temperature at which the steam boiler are capable to withstand • 200°C • 280°C • 540°C • 358°C
Last Answer : • 540°C
Description : What is the temperature at which the steam boiler are Capable to withstand a. 200°C b. 280°C c. 540°C d. 358°C
Last Answer : c. 540°C
Description : When vapour is cooled at constant total system volume, the _______ changes. A] Volume. B] Pressure C] Temperature. D] None of the mentioned
Last Answer : B] Pressure
Description : When vapour is compressed isothermally the ____________ changes. A] Volume. B] Pressure C] Temperature D] None of the mentioned
Last Answer : A] Volume.
Description : The economiser is used in boilers to........ A]Increase thermal efficiency of boiler B]Economise on fuel C]Extract heat from the exhaust the gases D]Increase flue gas temperature
Last Answer : A]Increase thermal efficiency of boiler
Description : The temperature and pressure in saturated stem has__________relationship a) Direct b) indirect c) Neither of above d) both a and b
Last Answer : b) indirect
Description : What is the main disadvantage of Lamont boiler ? a. Less flexible in design b. Low heat transfer rate c. Formation of bubbles d. Low steam generation capacity
Last Answer : c. Formation of bubbles
Description : Where is water steam separator drum located in Lamont boiler ? a. Inside of the boiler b. Right above the furnace c. Before the feed water pump d. Outside the boiler
Last Answer : d. Outside the boiler
Description : What type of steam is generated by evaporator tube of Lamont boiler ? a. Saturated steam b. Unsaturated steam c. Superheated steam d. Flash steam
Last Answer : a. Saturated steam
Description : In which year was Lamont boiler invented? a. 1905 b. 1910 c. 1920 d. 1925
Last Answer : d. 1925
Description : What is the pressure range between which Lamont boiler operator ? a. 80-120 bar b. 120-160 bar c. 180-360 bar d. 450-560 bar
Last Answer : b. 120-160 bar
Description : Through which does the even circulation of water is possible in Lamont boiler ? a. Nozzles b. Water trough c. Feed pump d. Hose
Last Answer : a. Nozzles