Detecting and monitoring carbon monoxide assures the air/fuel ratio is not too rich as
a. The excess air is trimmed
b. Excess air is let out
c. Both a. & b.
d. None of above

1 Answer

Answer :

a. The excess air is trimmed

Related questions

Description : It is easy to detect and monitor excess air a. As oxygen not used for combustion is heated and discharged with the exhaust gases. b. Oxygen is discharged without heating c. Both a. & b. d. None of above

Last Answer : a. As oxygen not used for combustion is heated and discharged with the exhaust gases.

Description : Based on the exhaust gas analysis, a controller maintains stoichiometric combustion __ a. by commanding a servo motor to adjust the combustion air damper b. By commanding servo motor to adjust the fuel supply valve. c. Both a. & b. d. None of the above.

Last Answer : c. Both a. & b.

Description : Combustion is the ideal air/fuel ratio where a. the mixing proportion is correct, b. the fuel is completely burned c. the oxygen is entirely consumed d. All of the above

Last Answer : d. All of the above

Description : Green coal, in order to be burnt, must be (A) Heated sufficiently (B) Burnt in excess air (C) Heated to its ignition point (D) Burnt as powder

Last Answer : (C) Heated to its ignition point

Description : Which of these is a ‘fissile fuel’? a. Thorium b. Carbon c. Potassium d. Graphite

Last Answer : a. Thorium

Description : The biggest loss in the boiler is a) Moisture in fuel b) Dry flue gases c) Steam formation d) Unburnt carbon

Last Answer : b) Dry flue gases

Description : Find false statement about effect of sulphur in fuel? (A) It has heating value (B) It helps in electrostatic precipitation of ash in flue gases (C) It leads to corrosion of air heaters, ducting, etc. if flue gas exit temperature is low (D) It erodes furnace walls

Last Answer : (D) It erodes furnace walls

Description : Oxygen trim control strategy __ a. continuously measures the oxygen content in the flue gas b. adjusts the combustion air flow c. Continually tuning the air-fuel mixture. d. All of above

Last Answer : d. All of above

Description : Which of these is an output of a ‘Furnace’? a. Fuel gas b. Cool Air c. Flue gases d. Water Vapor

Last Answer : c. Flue gases

Description : What is the function of boiler? • To burn the fuel in a confined closed system With the supply of air • To generate steam in varying pressure • To generate steam at constant pressure • To produce flue gases by burning fuel at a given pressure

Last Answer : • To generate steam at constant pressure

Description : Which of the following is not a result of the excess of impurity in boiler-feed. a) Scale and sludge formation b) Decomposition c) Corrosion, priming and foaming d) Caustic embrittlement

Last Answer : b) Decomposition

Description : Overfire burning in a furnace is a phenomenon characterised by (A) Supply of excess fuel (B) Supply of excess air (C) Burning carbon monoxide and other incombustible in upper zone of furnace by supplying more air (D) None of these

Last Answer : (C) Burning carbon monoxide and other incombustible in upper zone of furnace by supplying more air

Description : A liquid/gaseous fuel containing hydrocarbons and high amount of sulphur is burnt with 40% excess air. The flue gas still contains large amount of carbon monoxide. This may be due to the (A) Presence of large ... fuel (C) High sulphur content in the fuel (D) Lack of thorough mixing of fuel with air

Last Answer : (D) Lack of thorough mixing of fuel with air

Description : Overfire burning" in a furnace is a phenomenon characterised by the (A) Supply of excess fuel (B) Supply of excess air (C) Burning of carbon monoxide and other incombustibles in upper zone of furnace by supplying more air (D) None of these

Last Answer : (C) Burning of carbon monoxide and other incombustibles in upper zone of furnace by supplying more air

Description : For process boilers , combustion air fans must meet the following requirements ___ a. The fan motor shall be driven by a variable speed drive b. The fan motor shall include controls that limit the fan motor demand to no more than 30 %. c. Both a. & b. d. None of the above

Last Answer : c. Both a. & b.

Description : A flue damper and a vent damper are two examples of _______ a. Combustion air positive shut off devices b. Combustion air negative shut off devices c. Both a. & b. d. None of the above

Last Answer : a. Combustion air positive shut off devices

Description : Boiler works from application of which type of energies 1. Fuel combustion 2. Electricity 3. Nuclear energy 4. All of above

Last Answer : 4. All of above

Description : Presence of moisture in fuel oil would (A) Keep the burner tips cool (B) Aid in proper combustion (C) Because sputtering, possibly extinguishing flame (D) Clean the nozzles

Last Answer : (D) Clean the nozzles

Description : Which of the following is the combustion accessory of a boiler? • Fuel oil system • Gas system • Coal system • All of the above

Last Answer : • All of the above

Description : Industrial boilers are closed vessels that use a fuel source or electricity to generate ________for industrial purposes. • Fuel Food • Steam

Last Answer : • Steam

Description : A _______ incorporates a firebox or furnace in order to burn the fuel and generate heat. • Steam • Boiler • Hydrogen • None

Last Answer : • Boiler

Description : A -________ incorporates a firebox or furnace in order to burn the fuel and _________ heat. a. Boiler, generate b. Heat, boiler c. Steam, pressure d. None

Last Answer : a. Boiler, generate

Description : A __________ is a type of heat exchange system where water is heated to its' boiling point via combustion of a fuel blown through a tube submerged in water. a. Condensate loop b. Hyperbolic cooling tower c. Steam boiler d. All of above

Last Answer : c. Steam boiler

Description : A _______ incorporates a firebox or furnace in order to burn the fuel and generate heat. A Steam B Boiler C Hydrogen D None

Last Answer : B Boiler

Description : Boiler efficiency is a measure of how effectively _______ energy in fuel is converted into heat energy in steam going to the turbines A Chemical energy B Heat energy C Thermal energy D All of the above

Last Answer : A Chemical energy

Description : An economiser in a boiler........ A]Increases steam pressure. B]Increases steam flow C]Decreases fuel consumption D]Decreases steam pressure

Last Answer : C]Decreases fuel consumption

Description : The economiser is used in boilers to........ A]Increase thermal efficiency of boiler B]Economise on fuel C]Extract heat from the exhaust the gases D]Increase flue gas temperature

Last Answer : A]Increase thermal efficiency of boiler

Description : when steam is condensate volume is drastically……. a) reduces b) increase c) both a) & b) d) None of above

Last Answer : a) reduces

Description : If the water level inside the boiler were not carefully control cased… a) explosion b) overheat and fail c) both a) & b) d) None of above

Last Answer : c) both a) & b)

Description : The heat produced in this system is then rejected into the system as _______ a. Steam b. Boiler c. Both a & b d. None

Last Answer : a. Steam

Description : Direct relation between…….. &………of saturated steam, the amount of energy input to process easy to control. a) volume, pressure b) volume, temperature c) temperature, pressure d) None of above

Last Answer : c) temperature, pressure

Description : The product of efficiency & heat transferred to the working fluid is? a. Net temperature change b. Net work done c. Net enthalpy change d. None of the mentioned

Last Answer : b. Net work done

Description : In a steam condenser, the partial pressure of steam and air are 0.06 bar and 0.007 bar respectively. The condenser pressure is (A) 0.007 bar (B) 0.053 bar (C) 0.06 bar (D) 0.067 bar

Last Answer : (D) 0.067 bar

Description : Use of ______ is prohibited in process boilers. a. Use of a common gas b. combustion air control linkage c. jack shaft d. All of the above

Last Answer : d. All of the above

Description : Combustion air positive shut-off shall be provided on all newly installed _______ a. Grant boilers b. Process boilers c. Worcester boilers d. All of the above

Last Answer : b. Process boilers

Description : What is the reason to service a cooling tower? a) to ensure proper air flow b) to clean the tubes c) to inspect the water pump d) all of these

Last Answer : all of these

Description : What happens when air dissolves in condensate? a) non corrosive b) temperature of air increases c) corrosive d) none of above

Last Answer : c) corrosive

Description : Pick out the wrong statement. (A) High concentration of oxygen in flue gas means high stack loss (B) Gaseous fuels require the least % excess air for complete combustion (C) The ratio of fixed carbon to ... coal is called its 'fuel ratio' (D) Calorific value of natural gas is more than that of LPG

Last Answer : (D) Calorific value of natural gas is more than that of LPG

Description : Process boilers with capacity of 2.5 MMBtu/h and above are also referred as _ a. Natural draft boilers b. Atmospheric boilers c. Both a. And b. d. None of the above

Last Answer : a. Natural draft boilers

Description : If steam is pressurized _____ • It occupies more space • It occupies less space • Both are correct • None of the above

Last Answer : • It occupies less space

Description : The generated heat is transferred to water to make ______ the process of boiling. • Steam • Boiler • Both • None

Last Answer : • Steam

Description : The temperature and pressure in saturated stem has__________relationship a) Direct b) indirect c) Neither of above d) both a and b

Last Answer : b) indirect

Description : Which of the following statements about continuous cardiac output monitoring are true? A. Continuous cardiac output monitoring may unmask events not detected by intermittent cardiac output measurements. ... stroke volume by detecting changes in resistance to a small, applied alternating current.

Last Answer : Answer: AD DISCUSSION: Various techniques are available to measure cardiac output continuously. The advantages of continuous cardiac output monitoring, as compared with intermittent methods, are (1) ... function of the stroke volume, which then can be used to calculate the cardiac output

Description : What is the main disadvantage of Lamont boiler ? a. Less flexible in design b. Low heat transfer rate c. Formation of bubbles d. Low steam generation capacity

Last Answer : c. Formation of bubbles

Description : Where is water steam separator drum located in Lamont boiler ? a. Inside of the boiler b. Right above the furnace c. Before the feed water pump d. Outside the boiler

Last Answer : d. Outside the boiler

Description : What type of steam is generated by evaporator tube of Lamont boiler ? a. Saturated steam b. Unsaturated steam c. Superheated steam d. Flash steam

Last Answer : a. Saturated steam

Description : In which year was Lamont boiler invented? a. 1905 b. 1910 c. 1920 d. 1925

Last Answer : d. 1925

Description : What is the pressure range between which Lamont boiler operator ? a. 80-120 bar b. 120-160 bar c. 180-360 bar d. 450-560 bar

Last Answer : b. 120-160 bar

Description : Through which does the even circulation of water is possible in Lamont boiler ? a. Nozzles b. Water trough c. Feed pump d. Hose

Last Answer : a. Nozzles

Description : In what form are the boiler tube arrange in Lamont boiler ? a. Parallel in vertical b. Inclined vertically c. Parallel in horizontal d. Horizontally inclined

Last Answer : c. Parallel in horizontal