Oxygen trim control strategy __
a. continuously measures the oxygen content in the flue gas
b. adjusts the combustion air flow
c. Continually tuning the air-fuel mixture.
d. All of above

1 Answer

Answer :

d. All of above

Related questions

Description : Based on the exhaust gas analysis, a controller maintains stoichiometric combustion __ a. by commanding a servo motor to adjust the combustion air damper b. By commanding servo motor to adjust the fuel supply valve. c. Both a. & b. d. None of the above.

Last Answer : c. Both a. & b.

Description : Find false statement about effect of sulphur in fuel? (A) It has heating value (B) It helps in electrostatic precipitation of ash in flue gases (C) It leads to corrosion of air heaters, ducting, etc. if flue gas exit temperature is low (D) It erodes furnace walls

Last Answer : (D) It erodes furnace walls

Description : Which of these is an output of a ‘Furnace’? a. Fuel gas b. Cool Air c. Flue gases d. Water Vapor

Last Answer : c. Flue gases

Description : A flue damper and a vent damper are two examples of _______ a. Combustion air positive shut off devices b. Combustion air negative shut off devices c. Both a. & b. d. None of the above

Last Answer : a. Combustion air positive shut off devices

Description : Combustion is the ideal air/fuel ratio where a. the mixing proportion is correct, b. the fuel is completely burned c. the oxygen is entirely consumed d. All of the above

Last Answer : d. All of the above

Description : What is the function of boiler? • To burn the fuel in a confined closed system With the supply of air • To generate steam in varying pressure • To generate steam at constant pressure • To produce flue gases by burning fuel at a given pressure

Last Answer : • To generate steam at constant pressure

Description : The economiser is used in boilers to........ A]Increase thermal efficiency of boiler B]Economise on fuel C]Extract heat from the exhaust the gases D]Increase flue gas temperature

Last Answer : A]Increase thermal efficiency of boiler

Description : measures oxygen and temperature of the flue gas. a) Fuel efficiency monitor. b) Combustion analyzer. c) Contact thermometer. d) Infrared thermometer.

Last Answer : Combustion analyzer

Description : The biggest loss in the boiler is a) Moisture in fuel b) Dry flue gases c) Steam formation d) Unburnt carbon

Last Answer : b) Dry flue gases

Description : Use of ______ is prohibited in process boilers. a. Use of a common gas b. combustion air control linkage c. jack shaft d. All of the above

Last Answer : d. All of the above

Description : Which of the following is the combustion accessory of a boiler? • Fuel oil system • Gas system • Coal system • All of the above

Last Answer : • All of the above

Description : If oxygen content in the flue gas rises too high, fuel is being wasted by (A) Incomplete combustion (B) Dry gas/stack gas loss (C) Moisture loss (D) None of these

Last Answer : (B) Dry gas/stack gas loss

Description : It is easy to detect and monitor excess air a. As oxygen not used for combustion is heated and discharged with the exhaust gases. b. Oxygen is discharged without heating c. Both a. & b. d. None of above

Last Answer : a. As oxygen not used for combustion is heated and discharged with the exhaust gases.

Description : Boiler works from application of which type of energies 1. Fuel combustion 2. Electricity 3. Nuclear energy 4. All of above

Last Answer : 4. All of above

Description : Presence of moisture in fuel oil would (A) Keep the burner tips cool (B) Aid in proper combustion (C) Because sputtering, possibly extinguishing flame (D) Clean the nozzles

Last Answer : (D) Clean the nozzles

Description : A __________ is a type of heat exchange system where water is heated to its' boiling point via combustion of a fuel blown through a tube submerged in water. a. Condensate loop b. Hyperbolic cooling tower c. Steam boiler d. All of above

Last Answer : c. Steam boiler

Description : In practical operation of any furnace, zero oxygen percentage or theoretical CO2 percentage in flue gas is rarely achieved, because of (A) Use of non-preheated combustion air (B) Use of pulverised solid ... of fuel & air and infiltration of air (D) Use of excessive positive draft in the furnace

Last Answer : (C) Imperfect mixing of fuel & air and infiltration of air

Description : Combustion of fuel in a furnace with oxygen enriched air results in higher (A) Flue gas volume (B) Flame temperature (C) Fuel consumption (D) Stack loss

Last Answer : (B) Flame temperature

Description : Pick out the wrong statement. (A) High concentration of oxygen in flue gas means high stack loss (B) Gaseous fuels require the least % excess air for complete combustion (C) The ratio of fixed carbon to ... coal is called its 'fuel ratio' (D) Calorific value of natural gas is more than that of LPG

Last Answer : (D) Calorific value of natural gas is more than that of LPG

Description : A carbonaceous fuel (containing no H2 or hydrocarbons) is burnt and the resulting flue gas contains 21% CO2 . It means that (A) 21% excess air has been used for combustion (B) 21% excess oxygen has ... (C) Complete combustion of fuel has taken place (D) No excess air has been used for combustion

Last Answer : (C) Complete combustion of fuel has taken place

Description : Too much of excess air in combustion results in high (A) Fuel consumption for the same heat load (B) Stack gas temperature (C) Percentage of oxygen in flue gases (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Volumetric composition of flue gas analysed with the Orsat apparatus is : CO2 = 12%, O2 = 8%, CO = nil, N2 = 80%. This flue gas composition indicates that (A) Pure oxygen has been used for combustion ... very high (C) Excess air has been used for combustion (D) Hydrogen is not present in the fuel

Last Answer : (C) Excess air has been used for combustion

Description : Oxygen content in a flue gas was found to be 4%. It implies that excess air used for combustion was around __________ percent. (A) 4 (B) 96 (C) 20 (D) 40

Last Answer : (C) 20

Description : The diameter of internal flue tubes of a Lancashire boiler is about _______ that of it’s shell a. One fourth b. One third c. Two fifth d. One half

Last Answer : c. Two fifth

Description : Fire tube boilers are those in which a) Flue gases pass through tubes and water around it b) Water passes through the tubes and flue gases around it c) Work is done during adiabatic expansion d) Change is enthalpy

Last Answer : a) Flue gases pass through tubes and water around it

Description : Water tube boilers are those in which a) Flue gases pass through tubes and water around it b) Water passes through the tubes and flue gases around it c) Work is done during adiabatic expansion d) Change is enthalpy

Last Answer : b) Water passes through the tubes and flue gases around it

Description : For process boilers , combustion air fans must meet the following requirements ___ a. The fan motor shall be driven by a variable speed drive b. The fan motor shall include controls that limit the fan motor demand to no more than 30 %. c. Both a. & b. d. None of the above

Last Answer : c. Both a. & b.

Description : Combustion air positive shut-off shall be provided on all newly installed _______ a. Grant boilers b. Process boilers c. Worcester boilers d. All of the above

Last Answer : b. Process boilers

Description : During combustion of a gaseous fuel, the presence of a non-luminous flame is an indication of the (A) Incomplete combustion (B) Complete combustion (C) High oxygen in flue gas (D) None of these

Last Answer : (B) Complete combustion

Description : Incomplete combustion of a fuel is characterised by the high __________ in the flue gas. (A) Smoke (B) Temperature (C) Oxygen (D) Carbon monoxide

Last Answer : (D) Carbon monoxide

Description : The _____________ sensor senses the temperature of the engine coolant, and from this data the computer adjusts the mixture strength to rich side for cold starting. a) engine temperature b) exhaust gas c) air flow d) air inlet temperature

Last Answer : Answer: a Explanation: The engine temperature sensor senses the temperature of the engine coolant, and from this data the computer adjusts the mixture strength to rich side for cold starting while the ... gas senor senses the amount of oxygen in the engine exhaust and calculates air-fuel ratio.

Description : An economiser in a boiler........ A]Increases steam pressure. B]Increases steam flow C]Decreases fuel consumption D]Decreases steam pressure

Last Answer : C]Decreases fuel consumption

Description : Pitch creosote mixture (PCM) as compared to furnace oil is a better fuel, because its (A) Emissivity factor is higher (B) Sulphur content is lower (C) Flue gas has lower dew point thereby facilitating more waste heat recovery (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Higher efficiency in the combustion of solid fuel cannot be achieved by (A) Proper fuel preparation (B) Keeping the flue gas exhaust temperature very high (C) Adopting efficient-fuel firing technique & equipment (D) Supplying correct quantity of combustion air

Last Answer : (B) Keeping the flue gas exhaust temperature very high

Description : The main drawback of supplying more excess air in the combustion of fuel is the (A) Excessive power requirement of air blower (B) Enhanced sensible heat loss in the flue gas (C) Intermittent and uncontrolled combustion of the fuel (D) High exit flue gas temperature from the furnace

Last Answer : (B) Enhanced sensible heat loss in the flue gas

Description : Economizer is provided to utilize the flue gas heat for ___ a) preheating the boiler feed water b) preheating the stock c) preheating the combustion air d) preheating fuel

Last Answer : preheating the boiler feed water

Description : Detecting and monitoring carbon monoxide assures the air/fuel ratio is not too rich as a. The excess air is trimmed b. Excess air is let out c. Both a. & b. d. None of above

Last Answer : a. The excess air is trimmed

Description : Incomplete combustion of fuel in the furnace is judged by high __________ of the flue gases. (A) CO content (B) Dew point (C) CO2 content (D) O2 content

Last Answer : (A) CO content

Description : Which of the following accounts for maximum energy loss in a boiler? (A) Flue gases (B) Ash content in the fuel (C) Incomplete combustion (D) Unburnt carbon in flue gases

Last Answer : (A) Flue gases

Description : High sulphur content in a fuel __________ of the flue gases. (A) Decreases the dew point (B) Increases the dew point (C) Reduces the combustion efficiency by limiting the permissible temperature reduction (D) Both (B) and (C)

Last Answer : (D) Both (B) and (C)

Description : Combustion of which fuels from following is source of heat for boiler 1. Wood 2. Coal 3. Oil 4. All of above

Last Answer : 4. All of above

Description : Boiler is a enclosed vessel that provides a) Expansion b) Ignition c) Combustion d) None of the above

Last Answer : c) Combustion

Description : Basic Parts of a Boiler. Burner, • the combustion chamber, • the heat exchanger • All of the above

Last Answer : • All of the above

Description : A boiler is an enclosed vessel that provides a means for ________ and ______ heat to water until it becomes hot water or steam. a. Generate, boiler b. Condenser, loop c. Combustion, transfers d. All of above

Last Answer : c. Combustion, transfers

Description : Oxygen enrichment of combustion air does not result in increase of the (A) Flame temperature (B) Oxygen in the flue gas (C) Stack loss (D) Heat transfer rate in the furnace

Last Answer : (B) Oxygen in the flue gas

Description : Out of the following fuels used in a furnace exhausting flue gas at a temperature of 600°C, the percentage stack loss will be maximum in case ofcomplete combustion of (A) Furnace oil with air (B) Furnace oil with oxygen (C) Blast furnace gas with air (D) Blast furnace gas with oxygen

Last Answer : (C) Blast furnace gas with air

Description : The _____________ sensor, checks the temperature of the ambient air entering the engine for fine tuning the mixture strength. a) engine temperature b) exhaust gas c) air flow d) air inlet temperature

Last Answer : Answer: d Explanation: The air inlet temperature sensor, checks the temperature of the ambient air entering the engine for fine tuning the mixture strength whereas the engine temperature sensor senses the ... gas senor senses the amount of oxygen in the engine exhaust and calculates air-fuel ratio.

Description : What is the reason to service a cooling tower? a) to ensure proper air flow b) to clean the tubes c) to inspect the water pump d) all of these

Last Answer : all of these

Description : Acid dew point temperature (ADT) of a flue gas produced by the combustion of a fuel containing 1% sulphur may be about __________ °C. (A) 80 (B) 130 (C) 180 (D) 250

Last Answer : (B) 130

Description : Efficiency of the combustion of a fuel is judged by the __________ the flue gas. (A) % of CO2 in (B) % of O2 in (C) Temperature of (D) Colour of

Last Answer : (B) % of O2 in