The function of measurement system is/are _____.

1 Answer

Answer :

The function of measurement system are indicating, recording and controlling function.

Related questions

Description : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3-phase 3 ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Last Answer : Measurement of power and power factor of a 3-phase system by two wattmeter method can be obtained in case of  1. Balanced load and balanced source  2. Balanced source with 3-phase 3-wire unbalanced load  3. Unbalanced source with 3- ... b) 2, 3 and 5 (c) 1, 2, 3, 4 and 5 (d) 1, 2, 3 and 5 

Last Answer : In the case of power measurement by two wattmeter method in a balanced 3Φ system with a pure inductive load both the Wattmeter will indicate the same but of opposite sign.

Last Answer : Commonly used instruments in power system measurement are induction.

Description : Which of the following instruments can be used for measurement of very high value resistances such as insulation resistance in industries? A) Wheatstone bridge B) Megger C) Ohm-meter D) Resistive potentiometer 

Last Answer : Which of the following instruments can be used for measurement of very high value resistances such as insulation resistance in industries? A) Wheatstone bridge B) Megger C) Ohm-meter D) Resistive potentiometer 

Description :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the connections of current coil. the ... kVAR B) 0.2 & 6 √3 kVAR C) 0.32 & 2 kVAR D) 0.32 & 2 √3 kVAR

Last Answer :  In the measurement of power of balanced load by two wattmeter method in a 3-phase circuit, The readings of the wattmeters are 4 kW and 2 kW respectively, the later is being taken after reversing the ... of current coil. the power factor and reactive power of the load is 0.2 & 6 √3 kVAR

Description : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging:

Last Answer : For power measurement of three phase circuit by two wattmeter method, when the value of power factor is less than 0.5 lagging: One of the wattmeter connections will have to be reversed

Description : The measurement range of an ammeter can be increased by using a:

Last Answer : The measurement range of an ammeter can be increased by using a: low resistance in shunt

Description : Clamp on ammeter is used for measurement of:

Last Answer : Clamp on ammeter is used for measurement of: large alternating currents

Description : Weins bridge is used for measurement of frequency in the applied voltage waveform is measurement of frequency in the applied voltage waveform is   (A)sinusoidal (B) square (C) rectangular (D) triangular

Last Answer : Weins bridge is used for measurement of frequency in the applied voltage waveform is measurement of frequency in the applied voltage waveform is sinusoidal 

Description : Integrating principle in the digital measurement is the conversion of   (a) Voltage to time (b) Voltage to frequency (c) Voltage to current (d) Current to voltage

Last Answer : Integrating principle in the digital measurement is the conversion of Voltage to frequency

Description : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is (A) Zero (B) Leading (C) Lagging (D) Unity

Last Answer : In the measurement of power by two wattmeter method, when the readings of the two wattmeters are equal, the power factor is Unity

Description : For measurement of radio frequency ac signals __________ type meter is used

Last Answer : For measurement of radio frequency ac signals thermo-couple type meter is used

Description : Measurement of a non -electrical quantity involves the following four subsystems:  a) amplifier block b) display block c) instrumentation block d) transducer block  The correct, sequence in which these block occur is  (1) d,a,c,b (2) d, c, a, b (3) a, c, b, d (4) a, b, c, d

Last Answer : Measurement of a non -electrical quantity involves the following four subsystems:  a) amplifier block b) display block c) instrumentation block d) transducer block  The correct, sequence in which these block occur is d,a,c,b

Description : The bridge most suited for measurement of a four-terminal resistance in the range of 0.001 Ohm to 0.1 Ohm (A) Wien’s bridge (B) Kelvin double bridge (C) Maxwell’s bridge (D) Shering Bridge

Last Answer : The bridge most suited for measurement of a four-terminal resistance in the range of 0.001 Ohm to 0.1 Ohm (A) Wien’s bridge (B) Kelvin double bridge (C) Maxwell’s bridge (D) Shering Bridge

Description : Accurate measurement of very low resistances is possible with (A) Megger (B) Wheatstone Bridge (C) Kelvin’s Double Bridge (D) Wagner’s Earthing Device

Last Answer : Accurate measurement of very low resistances is possible with Kelvin’s Double Bridge

Last Answer : A measure of the reproducibility of measurement is known as Precision.

Last Answer : The absolute measurement of resistance is done by Lorenz method.

Last Answer : MISC meter not recommended for DC measurement because the error is high due to the hysteresis effect.

Last Answer : Ryall crest voltmeter is used for measurement of High AC voltage.

Last Answer : An instrument to be used for measurement and control should preferably have Linear output and fast response

Last Answer : Kelvin double bridge is best suited for the measurement of: Low resistance

Last Answer : Megger is an instrument used for the measurement of: High resistance and insulation resistance

Last Answer : Hay’s Bridge is suitable for the measurement of: Inductances with Q>10.

Last Answer : The power measurement in a balanced 3-phase circuit can be done by: One wattmeter method, Two wattmeter method, Three wattmeter method.

Last Answer : For measurement of inductance having high value, we should use Hay's bridge.

Last Answer : For measurement of mutual inductance we can use Heaviside bridge.

Description : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be?

Last Answer : In a 3-phase power measurement by two wattmeter method the reading of one of the wattmeter was zero. The power factor of the load must be 0.5.

Description : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was?

Last Answer : In a 3-phase power measurement by two wattmeter method, both the watt meters had identical readings. The power factor of the load was unity.

Description : In a standard multimeter for measuring AC voltage, parameter of _____ voltage is measured

Last Answer : In a standard multimeter for measuring AC voltage, parameter of RMS voltage is measured

Description : Moire fringes are used to measure rotary displacement along with _____.

Last Answer : Moire fringes are used to measure rotary displacement along with optical encoders only.

Last Answer : Integrating instruments are those which measure the total quantity of electricity delivered in a particular time.

Description : The use of _____ instruments is merely confined within laboratories as standardising instruments.

Last Answer : The use of absolute instruments is merely confined within laboratories as standardizing instruments.

Description : Business enterprise is separate from its owner according to _____ concept. a) Money measurement concept b) Matching concept c) Entity concept d) Dual aspect concept

Last Answer : c) Entity concept

Description :  The use of thermocouple meters for AC measurement leads to a meterscale which is _____.

Last Answer :  The use of thermocouple meters for AC measurement leads to a meterscale which is square law.

Description : State the function of ‘Signal Conditioner’ in measurement system.

Last Answer : Function of Signal Conditioner' :-- In Mechatronics systems, processing and controlling of physical parameters like temperature, pressure, flow, etc. is carried out by converting them into electrical signals by means of ... signal as require. vi) it help for impedance from source to load, 

Last Answer : The function of shunt in an ammeter is to by pass the current.

Description : Which one is not a function of money? (1) Transfer of value (2) Store of value (3) Price stabilization (4) Value measurement

Last Answer : (3) Price stabilization Explanation: Generally, economists have defined four types of functions of money which are as follows: (i) Medium of exchange (transfer of value) (ii) Measurement of value, ... deferred payments, and (iv) Store of value. Price stabilization is a function of monetary policy.

Description : The primary components of the quality management function are : 1. quality planning  2. quality control and assurance  3. quantitative measurement  4. quantitative assessment of the project

Last Answer : 5. a and b

Description : Which of these is not a function of money? (a) Means of exchange ; (b) Store value ; (c) Power indicator ; (d) Measurement of value

Last Answer : (c) Power indicator ;

Description : The function of measurement includes: (A) Prognosis (B) Diagnosis (C) Prediction (D) All of the above

Last Answer : (D) All of the above

Description : Which one is not a function of money ? (1) Transfer of value (2) Store of value (3) Price stabilisation (4) Value measurement

Last Answer : Price stabilisation