State any eight causes of fire. 

1 Answer

Answer :

Following are the Causes of electrical Fires:- 1. Overloading on cables/wires/machine causes possibility of fire. 2. Use of too many device plugged into a circuit, causing heated wire & possible a fire. 3. The majority of fires are caused due to selection of incorrect rating of the fuses or use of incorrect rating MCB/RCCB or incorrect setting of safety switch. 4. If insulation damage/deterioration, a short circuit may occur causing fire. 5. Poor joints in wiring/cables may cause overheating & lead to fire. 6. Due to loose connection in the electrical installation may produces spark causes fire. 7. Failing to replace worn out / defective equipment / Insulation /Cable/wire 8. Due to old wiring and unsafe appliances 9. Stored highly flammable liquids near electric oven/furnace. 10. Kept electric heaters near curtains/furniture. 11. Electrical faults inside appliances are a common cause of electric fire. 12. Fires may be caused if the installations are not maintained properly. 13. Due to use of poor quality of material also causes electric fire. 14. Faulty electrical installation may cause fire. 15. If clearances are not maintain as per voltage level there is possibility of sparking leads to fire. 16. Electrical installation & equipment’s used in hazards area are not used as per the specification/type of protection.

Related questions

Description : State any eight safety precautions to be followed while working with an electric installation. 

Last Answer : Wear safety boot and use right tool for the right job

Description : List any eight contamination agents of the transformer oil. 

Last Answer : The insulating oil gets contaminated when the following impurities are present in oil. 1. Presence of dissolved moisture content. 2. Presence of water content. 3. Presence of dissolved gases ... sulpher content 9. Presence of acetones content. 10. Presence of dissolved oil decay products content

Description : List any four internal causes for abnormal operation of electrical equipment’s. 

Last Answer : Internal causes:- 1. Open circuit 2. Short circuit 3. Earth fault 4. Loose connection 5. Deposit of dirt and dust near ventilation passage 6. Low insulation resistance 7. Improper maintenance 8. Poor ... problems 13. Failure of cooling system 14. Excess wear and tear of internal parts 15. Ageing.

Description : State types of maintenance. Explain each with example. 

Last Answer : Maintenance are classified as below:- 1. Preventive Maintenance (PM) 2. Routine /daily maintenance 3. Periodic maintenance/Time based maintenance (TBM) 4. Predictive maintenance (PDM) 5. ... by the manufacturer. It involves partial or complete dismantling of the equipment/machine and overhaul.

Description : State the methods of Neutral Grounding. State difference between Earthing and grounding. 

Last Answer : Neutral Grounding connections are of three types:  1. Solid earthing 2. Resistance earthing 3. Reactance earthing SR. NO. Earthing Grounding 1 Earthing means connecting the dead part ... earthing provides suitable means for earth fault protecting system.  10

Description : State the basic requirements of foundation for :(i) Static equipment’s (ii) Rotating equipment’s

Last Answer : Following are the basic requirements of foundation to be considered in designing the machine foundation for :(i) Static equipment's (ii) Rotating equipment's  1. Depth of foundation should be ... it.  11. The dimension of foundation should be proportional to safe bearing capacity of soil.

Description : State the methods used to measure insulation resistance and explain Dielectric Absorption method.

Last Answer : There are three types of tests for measuring insulation resistance:  1. Spot test reading or Short Time test  2.Time-resistance test or Dielectric absorption test or Testing methods based on the PI & DAR  3. ... and if value of PI is less than 2 and value of DAR is less than 1.25

Description : State and explain properties of transformer oil.  

Last Answer : Following are the properties of transformer oil:-  1. Dielectric strength :- It should be have a high dielectric strength  2. Specific resistance:- It should be have a high Specific ... be not contain impurities such as sulpher & its compounds to avoid rusting & sludge formation. 

Description : State the procedure for developing preventive maintenance schedule. 

Last Answer : Procedure of PM is as below:-  Step 1:- Inspection: What to inspect and how to inspect? Maintenance engineer / team should inspect the plan under working condition. Prepare the check ... :- Check the availability of trained & skilled technician to do maintenance before starting the work.

Description : State the objective of testing. Explain the role of BIS (Bureau of Indian Standards) in testing of electrical machines. 

Last Answer : 1. Objective of testing is to finding error/defects in machine/equipment/ product. 2. To confirm whether the results obtain during testing are within tolerance limits specified by BIS / ISS 3. To ... BIS/ISS specified standards. 5. To avoid in convinces & accidents BIS plays important role.  

Description : State any one application of each tool : (i) Earth tester (ii) Megger (iii) Bearing puller (iv) Growler 

Last Answer : i) Earth Tester :- It is used to measure earth resistance.  ii) Megger :- Megger is used to find out (measure) insulation resistance of electrical machine/equipment.  iii) ... is an electrical device used to find out shorted turn faults in armature winding and stator winding of motor.

Description : State any four advantages of preventive maintenance. 

Last Answer : Following are the advantages of Preventive Maintenance:- 1. It increases life of machine/equipment. 2. It prevents premature failure. 3. It keeps the machine in good working condition by reducing wear and ... more expensive than the same job done PM/preplanned (and may take 10 times longer).

Description : State the factors on which severity of electric shock depends. 

Last Answer : The severity of shock depends on following factors.  1. Magnitude voltage of the system.  2. The period or duration for which the area of contact with lives part.  3. It is also depends on ... 200mA  May cause fibration of heart  6 Above -200mA Causes death, severe burns 

Description : Compare direct and Indirect method of testing.  

Last Answer : Sr No.  Parameter Direct Testing Indirect Testing   1 Nature of loading  The m/c is actually loaded at full load. The m/c is not actually loaded but machine run on N.L. 2 ... 1.O.C. and S.C test on transformer/Alternator / I.M. , 2. Swinburne test on DC machines. 

Description : Explain importance and purpose of earthing. 

Last Answer : Importance and purpose of earthing is as below:- 1. To provide an alternative path for the leakage current to flow towards earth. 2. To save human life from danger of electrical shock due to ... equipment body (frame) below the earth potential in the event of fault from safety point of view. 

Description : Describe any four methods used to reduce earth resistance.  

Last Answer : To reduce earth resistance following steps/methods are necessary: 1. Earth pit of more depth & width- breadth should be made. 2. Use of higher size/cross section of earthing material like ... galvanized. 12. Electrodes should be placed in the earth in the upright vertical position. 

Description : Classify the insulating materials as per operating temperature. Give two examples of each type.

Last Answer : Sr.No.  Insulation Classes  Maximum permissible temperature (0C) Insulating Material 1 Class-Y or O  900 Cotton, silk, paper, press board, wood, cellulose-, PVC, VIR. (Cotton, silk, ... adhesive coating.  7 Class- C  Over 1800 Porcelain, ceramics, glass, quartz. 

Description : Explain vacuum impregnation method used for Re-varnishing of insulation with neat diagram.

Last Answer : Figure of process of vaccum impregnation:-  Explain the process of vacuum impregnation:- The plant consists of: 1. A large air tight chamber (VIC) i.e. processing or impregnation chamber. 2 ... )curing temperature varies from 90°C to 110°C for 10-20 minutes in some cases one to two hours.

Description : Describe Effect of misalignment of direct coupled drives.

Last Answer : Following are the effects of misalignment of direct coupled drives:- 1. There will be excess vibrations. 2. Increase in noise level. 3. Increases in friction loss. 4. The shaft will bent. 5. There ... stresses on coupling & shaft. 13. Early wear & tear of both driving & driven machine.

Description : List routine tests to be conducted on 3 phase transformer as per 1S-2026-2011. 

Last Answer : Following tests are conducted/carried out on Transformer as per IS 2026 Routine tests of transformer include:- 1. Winding resistance measurement.(Both HV and LV winding ) 2. Measurement of ... Tests on on-load tap-changer, where appropriate. 11. To check against leakages through gaskets.

Description : Prepare troubleshooting chart for transformer as per IS- 10028-1981 (4 trouble) and Induction motor (4 troubles). 

Last Answer : Troubleshooting chart for I.M. :-  Sr.No Type of fault/abnormal conditions/Troubles Causes Remedies 1 Motor fails to start or not accelerate (Faults in starting supply ... 1.Unequal terminal voltage. 2. Single phase operation 3.Unbalanced voltage Rectify the Cause

Description : Describe the factors affecting preventive maintenance schedule. 

Last Answer : Following factors affect the PM schedule:- 1. Non availability of spares & raw material. 2. Non availability of tools, trackless, jacks, fixture required for PM. 3. Non availability of trained & skilled ... the work is held up for certain period. This is also a cause of disturbing a PM schedule.

Description : __________ is an interface for connecting eight or more data wires. A. Serial Port B. Fire wire C. Parallel Port D. None of the Above

Last Answer : C. Parallel Port

Description : If flag is set then control unit issues control signals that causes program counter to be incremented by 1. a. Zero b. One c. Three d. Eight

Last Answer : a. Zero

Description : A fire hose has a nozzle attached to it, and the nozzle discharges a jet of water into the atmosphere at a velocity of 20 m/s. this causes the joint of the nozzle with the hose to be in : (a) Tension (b) A state of zero stress (c) Compression (d) Bending stress

Last Answer : (a) Tension

Description : What causes a fire diesel pump to not stop?

Last Answer : You need to cut off the electricity. You can reach the cord and outlet safely, unplug it. In an area around oil well or somewhere else with flammable gasses or hydrocarbon vapor in the air, you may ... . A diesel will run with no normally supplied fuel or spark if there is enough fuel in the air.

Description : What causes the majority of fire- related deaths?

Last Answer : Smoke inhalation of gasses produced by the fire.

Description : The poem poses two causes of the end of the world? a) Love & hatred b) Desire & Ignorance c) Fire & Ice d) None of the above

Last Answer : c) Fire & Ice

Description : Presence of soluble organics in polluted water causes (A) Undesirable plants growth (B) Depletion of oxygen (C) Fire hazards (D) Explosion hazards

Last Answer : (B) Depletion of oxygen

Description : Presence of non-biodegradable substances, like alkyl benzene sulphonate (ABS) from the detergents in polluted water stream causes (A) Fire hazards (B) Explosion hazards (C) Persistent foam (D) Depletion of dissolved oxygen

Last Answer : (C) Persistent foam