An equipment which converts the latent or sensible heat of one fluid
into the latent heat of vaporisation of another, is called a
(A) Boiler
(B) Heat exchanger
(C) Recuperator
(D) Regenerato

1 Answer

Answer :

(B) Heat exchanger

Related questions

Description : In a cooling tower, water becomes cool by (A) Loosing sensible heat (B) Heat transfer to surroundings (C) Vaporisation due to heat loss to air (D) Loosing latent heat

Last Answer : (A) Loosing sensible heat

Description : In which of the waste heat recovery equipment, the flow of flue gas and air is alternately reversed after a fixed interval of time? (A) Recuperator (B) Regenerator (C) Waste heat boiler (D) None of these

Last Answer : (B) Regenerator

Description : Which of the following is not a continuous waste heat recovery equipment from the flue gases going out of furnace? (A) Economiser (B) Regenerator (C) Ceramic recuperator (D) Waste heat boiler

Last Answer : (B) Regenerator

Description : Sensible heat of hot industrial flue gases cannot be recovered by a/an (A) Economiser (B) Regenerator (C) Ceramic recuperator (D) None of these

Last Answer : (D) None of these

Description : Pick out the wrong statement. (A) Heat transfer by radiation cannot occur across an absolute volume (B) In case of a shell and tube heat exchanger, the pressure drop through the shell is ... The amount of heat involved in the condensation or vaporisation of 1 kg of a fluid is the same

Last Answer : (A) Heat transfer by radiation cannot occur across an absolute volume

Description : Heat in BTU necessary to increase the temperature of 1 lb of gas and its accompanying vapour by 1°F is called the (A) Latent heat (B) Humid heat (C) Specific heat (D) Sensible heat

Last Answer : (C) Specific heat

Description : In distillation column design, the McCabe-Thiele procedure is inadequate and a Ponchan-Savarit procedure is needed, when (A) Saturated feed is not used (B) An azeotrope forms (C) The latent ... vaporisation of the more and less volatile components are greatly different (D) A total condenser is used

Last Answer : (D) A total condenser is used

Description : Entrainer used in Azeotropic distillation should (A) Form a low boiling azeotrope with one of the constituents of the mixture (B) Form a new azeotrope of low relative volatility with one of the ... (C) Have high latent heat of vaporisation (D) Have high viscosity to provide high tray efficiency

Last Answer : (A) Form a low boiling azeotrope with one of the constituents of the mixture

Description : Heat sensitive materials with very high latent heat of vaporisation may be economically separated using (A) Liquid extraction (B) Distillation (C) Evaporation (D) Absorption

Last Answer : (A) Liquid extraction

Description : When the solvent dissolves very little of solute, then (A) Solvent of low latent heat of vaporisation should be used (B) Solvent of low freezing point should be used (C) Large quantity of solvent is required to extract the solute (D) Very small quantity of solvent is required

Last Answer : (C) Large quantity of solvent is required to extract the solute

Description : The solvent used in liquid extraction should not have high latent heat of vaporisation, because (A) The pressure drop and hence the pumping cost will be very high (B) It cannot ... by distillation may be prohibitively high (D) It will decompose while recovering by distillation

Last Answer : (C) Its recovery cost by distillation may be prohibitively high

Description : It is desired to concentrate a 20% salt solution (20 kg of salt in 100 kg of solution) to a 30% salt solution in an evaporator. Consider a feed of 300 kg/min at 30°C. The boiling point of the solution is 110°C, the latent heat of ... 3.06 10 5 (B) 6.12 10 5 (C) 7.24 10 5 (D) 9.08 10

Last Answer : (A) 3.06 × 10

Description : Clausius-Clapeyron Equation gives accurate result, when the (A) Vapour pressure is relatively low and the temperature does not vary over wide limits (B) Vapour obeys the ideal gas law and the latent heat of ... is negligible compared with that in the vapour state (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : High __________ is an undesirable property for a good refrigerant. (A) Specific heat (B) Latent heat of vaporisation (C) Viscosity (D) Specific vapor volume

Last Answer : (C) Viscosity

Description : ick out the undesirable property for a good refrigerant. (A) High thermal conductivity (B) Low freezing point (C) Large latent heat of vaporisation (D) High viscosity

Last Answer : (D) High viscosity

Description : Gibbs free energy per mole for a pure substance is equal to the (A) Latent heat of vaporisation (B) Chemical potential (C) Molal boiling point (D) Heat capacity

Last Answer : (B) Chemical potential

Description : The critical pressure at which the latent heat of vaporisation of steam becomes zero is __________ Kg/cm2. (A) 273.15 (B) 225.65 (C) 100.03 (D) 373.15

Last Answer : (B) 225.65

Description : McCabe-Thiele method of binary distillation does not assume that the (A) Sensible heat changes are negligible compared with latent heat changes (B) Molar latent heats of all components are equal (C) Heat of mixing is negligible (D) None of these

Last Answer : (D) None of these

Description : Removal of __________ heat is involved in the condensation of a vapor under saturated conditions. (A) Super (B) Sensible (C) Latent (D) Both (B) & (C)

Last Answer : (B) Sensible

Description : Net calorific value is the gross calorific value less the __________ heat of water in the product of combustion when cooled to 15°C. (A) Sensible (B) Latent (C) Sensible and latent (D) None of these

Last Answer : (C) Sensible and latent

Description : Evaporative cooling process employs a combination of cooling and humidification in which the (A) Sensible heat is added (B) Sensible heat is removed and the latent heat is added (C) Latent heat is removed (D) Sensible heat is added and latent heat is removed

Last Answer : Option B

Description : Pick out the wrong statement. (A) The condensing film co-efficient is about 3 times lower for vertical condenser as compared to the equivalent horizontal condenser for identical situation ( ... in a heat exchanger is controlled by the value of the film co-efficient, which is higher

Last Answer : (D) Overall heat transfer co-efficient in a heat exchanger is controlled by the value of the film co-efficient, which is higher

Description : Why high latent heat of vaporisation is desirable in a refrigerant ?

Last Answer : A high latent heat of vaporisation of refrigerant results in small amount of refrigerant and thus lesser circulation system of refrigerant for same tonnage.

Description : Steam at 1000C causes more severe burns than water at 100° C because (1) steam has no specific heat capacity (2) steam has latent heat of vaporisation (3) water has no specific heat capacity (4) water has latent heat of fusion

Last Answer :  steam has latent heat of vaporisation

Description : Choose the correct statement (a) A refrigerant should have low latent heat (b) If operating temperature of system is low, then refrigerant with low boiling point should be used (c) Pre-cooling and sub-cooling bf refrigerant are same (d) Superheat and sensible heat of a. refrigerant are same

Last Answer : Ans: b

Description : The refrigerant for a refrigerator should have (a) high sensible heat (b) high total heat (c) high latent heat (d) low latent heat

Last Answer : Ans: c

Description : What do the term sensible heat and latent heat mean?

Last Answer : Sensible heat: We can measure the rise in temperature. When we add more heat to a substance. Example - heat that added to water from 0º C to 100º C. This added heat is measured as sensible heat. ... at 100º C though we added more heat the temperature remains at 100º C till all water becomes steam.  

Description : What refers to the heat needed to change the temperature of the substances without changing its phases?  a. Latent heat  b. Sensible heat  c. Specific heat  d. entropy

Last Answer : Sensible heat

Description : Heat that cause change in phase without a change in temperature.  a) Sensible Heat  b) Latent Heat  c) Thermo Heat  d) None of the above

Last Answer : Latent Heat

Description : Heat that cause change in temperature at without a change in phase.  a) Sensible Heat  b) Latent Heat  c) Thermo Heat  d) None of the above

Last Answer : Sensible Heat

Description : Which of the following cannot be measured by a thermometer?  a. Latent Heat  b. Sensible Heat  c. Specific Heat  d. Heat of Fusion

Last Answer : Latent Heat

Description : Heat which causes a change in temperature of a substance.  a. Latent heat  b. Sensible heat  c. Specific heat  d. Heat of Fusion

Last Answer : Sensible heat

Description : n a chemical factory where dyes are made, wet cake at 30 OC consisting of 60% moisture  is put in a dryer to obtain an output having only 5% moisture, at atmospheric pressure. In  each batch about 120 ... dryer and the dryer efficiency  is 80%. Latent heat of steam at 4 kg/cm2 is 520 kcal/kg.

Last Answer : Given that   Qty of material dried per batch - 120 Kgs  Moisture at inlet - 60% a. The quantity of moisture removed per batch.  Water quantity in a wet batch - 120 x 0.6 = 72 Kgs.  Quantity of bone dry ... - 48/0.95 = 50.5 Kgs.  Equivalent water in a dry batch - 50.5 - 48 = 2.5 Kgs.

Description : The quantity of heat required to raise the temperature of a given substance by 1 oC is known as: a) sensible heat b) specific heat c) heat capacity d) latent heat

Last Answer : specific heat specific heat is the quantity of heat required to raise the temperature of 1 gram substance by 1 oC is

Description : Define sensible heat and latent heat 

Last Answer : Latent heat: It is defined as the quantity of heat required for phase change of working substance at saturation temperature. OR The amount of heat added at saturation temperature is called latent ... thermometer. OR The amount of heat added up to saturation temperature is called sensible heat.

Description : Define: (i) Sensible heat (ii) Latent heat

Last Answer : i) Sensible Heat: The heat in which change in temperature of a substance can be observed but phase remains unchanged that heat is known as Sensible heat.  This heat can be sensed by ordinary ... of fusion Heat at which Liquid Changes Phase to vapour is known as Latent heat of vaporization

Description : Basic Parts of a Boiler. Burner, • the combustion chamber, • the heat exchanger • All of the above

Last Answer : • All of the above

Description : In a 1-1 concurrent heat exchanger, if the tube side fluid outlet temperature is equal to the shell side fluid outlet temperature, then the LMTD is (A) ∞ (B) 0 ... temperature (D) Equal to the difference between hot fluid inlet temperature and cold fluid outlet temperature

Last Answer : (B) 0

Description : Heat transfer efficiency leading of energy conservation in a heat exchanger can be achieved by (A) Keeping the heat transfer surface clean (B) Enhancing the fluid pumping rate (C) Increasing the tube length (D) None of these

Last Answer : (A) Keeping the heat transfer surface clean

Description : Pick out the wrong statement. (A) Superheated steam is preferably not used for process heating because of its low heat transfer film co-efficient (B) In a shell and tube heat exchanger ... surface heat exchangers, when the direction of fluid flow is parallel to the axis of the tube

Last Answer : (C) S.I. unit of fouling factor is Watt/m2 .°K

Description : __________ heat exchanger is the most suitable, when the temperature of shell side fluid is much higher than that of tube side. (A) Single pass, fixed tube sheet (B) U-tube (C) Three pass, fixed tube sheet (D) None of these

Last Answer : (B) U-tube

Description : If the baffle spacing in a shell and tube heat exchanger increases, then the Reynolds number of the shell side fluid (A) Remains unchanged (B) Increases (C) Increases or decreases depending on number of shell passes (D) Decreases

Last Answer : (D) Decreases

Description : Vibrations in the tubes of a shell and tube heat exchanger is induced due to the (A) Flow of fluid on the tube and shell sides (B) Oscillations in the flow of shell/tube sides fluid (C) Vibrations ... piping and/or supports due to external reasons (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : A fluid is flowing inside the inner tube of a double pipe heat exchanger with diameter 'd'. For a fixed mass flow rate, the tube side heat transfer co￾efficient for turbulent flow conditions is proportional to (A) d 0.8 (B) d -0.2 (C) d -1 (D) d -1.8

Last Answer : (B) d -0.2

Description : Shell side pressure drop in a shell and tube heat exchanger does not depend upon the (A) Baffle spacing & shell diameter (B) Tube diameter & pitch (C) Viscosity, density & mass velocity of shell side fluid (D) None of these

Last Answer : (D) None of these

Description : Which characteristic of a fluid is not important in deciding its route in a shell and tube heat exchanger? (A) Corrosiveness (B) Fouling characteristic (C) Viscosity (D) None of these

Last Answer : (D) None of these

Description : In an extended surface heat exchanger, fluid having lower co-efficient (A) Flows through the tube (B) Flows outside the tubes (C) Can flow either inside or outside the tubes (D) Should not be used as it gives very high pressure drop

Last Answer : (B) Flows outside the tubes

Description : Pick out the wrong statement. (A) The controlling resistance in case of heating of air by condensing steam is in the air film (B) The log mean temperature difference (LMTD) for ... a pure fluid at a given pressure from liquid to vapor or vice-versa occurs at saturation temperature

Last Answer : (C) In case of a 1 - 2 shell and tube heat exchanger, the LMTD correction factor value increases sharply, when a temperature cross occurs

Description : LMTD for counter-flow and parallel flow heat exchanger will be the same, when the (A) Cold fluid is heated to a certain temperature by condensing steam (isothermal fluid) (B) Outlet temperature of ... temperature of hot fluid is less than the outlet temperature of the cold fluid (D) None of these

Last Answer : (A) Cold fluid is heated to a certain temperature by condensing steam (isothermal fluid)

Description : In a shell and tube heat exchanger, the shell side fluid velocity can’t be changed by changing the (A) Tube layout (B) Tube diameter (C) Tube pitch (D) Number of baffles

Last Answer : (B) Tube diameter