Which of the following is not a continuous waste heat recovery
equipment from the flue gases going out of furnace?
(A) Economiser
(B) Regenerator
(C) Ceramic recuperator
(D) Waste heat boiler

1 Answer

Answer :

(B) Regenerator

Related questions

Description : Sensible heat of hot industrial flue gases cannot be recovered by a/an (A) Economiser (B) Regenerator (C) Ceramic recuperator (D) None of these

Last Answer : (D) None of these

Description : In which of the waste heat recovery equipment, the flow of flue gas and air is alternately reversed after a fixed interval of time? (A) Recuperator (B) Regenerator (C) Waste heat boiler (D) None of these

Last Answer : (B) Regenerator

Description : In a low to medium temperature waste heat recovery system which of the device is most suitable a) Economiser b) Heat wheels c) air preheater d) Recuperator

Last Answer : Heat wheels

Description : Pick up the odd one out: b) Regenerator c) Recuperator d) Metallic recuperator e) Economiser

Last Answer : Economiser

Description : The economiser is used in boilers to........ A]Increase thermal efficiency of boiler B]Economise on fuel C]Extract heat from the exhaust the gases D]Increase flue gas temperature

Last Answer : A]Increase thermal efficiency of boiler

Description : Waste heat from the outgoing flue gases in a thermal power plant is recovered by a/an (A) Economiser (B) Steam superheater (C) Air preheater (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Which of the following is the most suitable for preheating combustion air above 650°C? (A) Regenerator (B) Metallic recuperator (C) Ceramic recuperator (D) None of these

Last Answer : (C) Ceramic recuperator

Description : Design of waste heat boiler for recovery of waste heat from furnace gases depends upon the (A) Quantity & temperature of waste gas (B) Dust concentration & nature of dust in waste gas (C) Corrosive nature of the waste gas (D) All (A), (B) and (C)

Last Answer : (B) Dust concentration & nature of dust in waste gas

Description : Thermal efficiency of furnaces can be improved by (A) Waste heat recovery from flue gas (B) Minimising heat losses from furnace walls (C) Maintaining proper draught (D) All (A), (B) and (C

Last Answer : (D) All (A), (B) and (C

Description : Pitch creosote mixture (PCM) as compared to furnace oil is a better fuel, because its (A) Emissivity factor is higher (B) Sulphur content is lower (C) Flue gas has lower dew point thereby facilitating more waste heat recovery (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : In a furnace, the heat taken by the charge/stock and the heat lost to the furnace structure & flue gases depends on the (A) Rate of firing and emissivity of flame (B) Thermal conductivity of the charge & ... (C) Nature of process; whether batch, continuous or intermittent (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : An equipment which converts the latent or sensible heat of one fluid into the latent heat of vaporisation of another, is called a (A) Boiler (B) Heat exchanger (C) Recuperator (D) Regenerato

Last Answer : (B) Heat exchanger

Description : Calculate the recoverable waste heat (Q, in kCal/hour) from flue gases using the followingparameters: V (flow rate of the substance) 2000 m3/hr r (density of the flue gas): 0.9 kg/m3 Cp (specific heat ... (temperature difference): 120 oC h (recovery factor): 50% a. 21600 b. 43200 c. 25600 d. 34000

Last Answer : 21600

Description : Air preheater is not used as a waste heat recovery system in a____. a) Boiler b) billet Reheating Furnace c) Heat treatment furnace d) compressor

Last Answer : compressor

Description : Recuperated is used mainly as a waste heat recovery system in a ____. a) Boiler b) Billet Reheating Furnace c) Compressor d) None of the above

Last Answer : Billet Reheating Furnace

Description : Which furnace employs an I.D. fan for the removal of flue gases from the furnace? (A) Coke oven (B) Blast furnace stoves (C) Beehive coke oven (D) High pressure boiler

Last Answer : (D) High pressure boiler

Description : The function of an economiser in a boiler is to preheat the (A) Feedwater (B) Combustion air (C) Pulverised coal (D) Furnace oil

Last Answer : (A) Feedwater

Description : Pick out the wrong statement. (A) A slight haze at the top of chimney indicates good combustion in the furnace (B) A bag filter incurs very small pressure drop and is very efficient for ... dust collection equipment for removal of submicronic dust particles present in flue gas (D) None of these

Last Answer : (B) A bag filter incurs very small pressure drop and is very efficient for removal of submicronic dust particles from flue gases at very high temperature

Description : Metallic recuperators are not used for waste heat recovery, if the hot flue gas temperature is above __________ °C, because corrosion prevails at higher temperatures. (A) 350 (B) 750 (C) 1050 (D) 1250

Last Answer : (B) 750

Description : To reduce the stack loss, heat recovery from flue gas can be done by (A) Preheating of cold stock (B) Preheating of combustion air (C) Steam generation in waste heat boilers (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : The heat recoverable from flue gases of furnaces depends on the (A) Thermal efficiency of furnace (B) Quantity of flue gases (C) Flue gas temperature drop through the furnace (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : White flue gas (resembling steam) coming out of the chimney of a thermal power plant indicates that the fuel used in the boiler furnace is (A) Tar (B) Coke oven gas (C) Pitch (D) Pulverised coke

Last Answer : (B) Coke oven gas

Description : Flue gases coming out from furnace is first going through a) Turbine b) Economizer c) Air pre-heater d) Chimney

Last Answer : Ans: Economizer

Description : Heat recovery equipment will be most effective when the temperature of flue gas is: a) 250oC b) 200 oC c)400 oC d) 280 oC

Last Answer : 400 oC

Description : Regenerators are used for waste heat recovery in (A) By-product coke ovens (B) Beehive coke oven (C) Blast furnace stoves (D) Soaking pits

Last Answer : (A) By-product coke ovens

Description : Heat transfer rate to the stock/charge in the furnace does not depend upon the (A) Emissivity of the refractory walls (B) Size of the furnace (C) Use of waste heat recovery equipments (D) Thickness of the stock

Last Answer : (C) Use of waste heat recovery equipments

Description : Recovery of waste heat from hot fluid to fluid is called: a) thermo compressor b) waste heat recovery boiler c) heat Pump d) economizer

Last Answer : heat Pump

Description : Recovery of heat from dryer exhaust air is a typical application of: a) Waste heat recovery boiler b) Heat pump c) Heat wheel d) Economizer

Last Answer : Heat wheel

Description : Which of the following accounts for maximum energy loss in a boiler? (A) Flue gases (B) Ash content in the fuel (C) Incomplete combustion (D) Unburnt carbon in flue gases

Last Answer : (A) Flue gases

Description : Water-tube boiler is the one, in which (A) Water passes through tubes and flue gases around it (B) Tube carrying hot flue gases are immersed in a pool of water (C) Tubes are placed in vertical position (D) None of these

Last Answer : Option A

Description : Water-tube boiler is the one, in which (A) Water passes through tubes and flue gases around it (B) Tube carrying hot flue gases are immersed in a pool of water (C) Tubes are placed in vertical position (D) None of these

Last Answer : Option A

Description : Which of the following is not an additive for flue gases from furnace to reduce its dew-point? (A) Ammonia (B) Fine dolomite (C) Alkaline powders (D) None of these

Last Answer : (D) None of these

Description : Furnace aerodynamics is related to the __________ in the furnace. (A) Movement of gases (B) Measurement of flue gas volume (C) Temperature control

Last Answer : (A) Movement of gases

Description : Incomplete combustion of fuel in the furnace is judged by high __________ of the flue gases. (A) CO content (B) Dew point (C) CO2 content (D) O2 content

Last Answer : (A) CO content

Description : Most of the phosphorous present in the blast furnace burden enters into (A) Hot metal (B) Flue gases (C) Slag (D) Refractory lining

Last Answer : (A) Hot metal

Description : What is the function of boiler? • To burn the fuel in a confined closed system With the supply of air • To generate steam in varying pressure • To generate steam at constant pressure • To produce flue gases by burning fuel at a given pressure

Last Answer : • To generate steam at constant pressure

Description : The biggest loss in the boiler is a) Moisture in fuel b) Dry flue gases c) Steam formation d) Unburnt carbon

Last Answer : b) Dry flue gases

Description : Refractory bricks having high thermal conductivity is desirable, when it is to be used in the (A) L.D. converter (B) Blast furnace (C) Rotary kiln (D) Recuperator

Last Answer : (D) Recuperator

Description : Use of economiser in a boiler plant reduces the fuel consumption for steam generation by about __________ percent. (A) 1 (B) 10 (C) 30 (D) 50

Last Answer : (B) 10

Description : An economiser in a boiler........ A]Increases steam pressure. B]Increases steam flow C]Decreases fuel consumption D]Decreases steam pressure

Last Answer : C]Decreases fuel consumption

Description : What are the benefits or the advantages of waste heat recovery units (WHRU)? a) Reduced Pollution b) Reduced equipment sizes c) Reduced auxiliary energy consumption. d) All of the above

Last Answer : All of the above

Description : Benefits of Waste Heat Recovery a. Reduction in pollution b. Reduction in equipment sizes c. Reduction in auxiliary energy consumption d. All of the above

Last Answer : Ans:- d. All of the above

Description : Find false statement about effect of sulphur in fuel? (A) It has heating value (B) It helps in electrostatic precipitation of ash in flue gases (C) It leads to corrosion of air heaters, ducting, etc. if flue gas exit temperature is low (D) It erodes furnace walls

Last Answer : (D) It erodes furnace walls

Description : Which of these is an output of a ‘Furnace’? a. Fuel gas b. Cool Air c. Flue gases d. Water Vapor

Last Answer : c. Flue gases

Description : Oxygen enrichment of combustion air does not result in increase of the (A) Flame temperature (B) Oxygen in the flue gas (C) Stack loss (D) Heat transfer rate in the furnace

Last Answer : (B) Oxygen in the flue gas

Description : Heat transfer rate to the charge/stock in a furnace does not depend upon the (A) Type of fuels viz. solid, liquid or gaseous (B) Flue gas temperature (C) Emissivity of refractory walls (D) Initial temperature of the charged stock

Last Answer : (A) Type of fuels viz. solid, liquid or gaseous

Description : Advantages of fluidised bed combustion are (A) Reduced NOx formation in flue gas (B) Lower furnace operating temperature (C) High heat transfer rate (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : The main drawback of supplying more excess air in the combustion of fuel is the (A) Excessive power requirement of air blower (B) Enhanced sensible heat loss in the flue gas (C) Intermittent and uncontrolled combustion of the fuel (D) High exit flue gas temperature from the furnace

Last Answer : (B) Enhanced sensible heat loss in the flue gas

Description : Ceramic coating material for furnace refractory, which increases itsemissivity and thus the radiation heat transfer rate in the furnace, comprises of (A) Graphite powder (B) Thoria (C) Zircon powder (D) Beryllium

Last Answer : (C) Zircon powder

Description : Economizer is provided to utilize the flue gas heat for ___ a) preheating the boiler feed water b) preheating the stock c) preheating the combustion air d) preheating fuel

Last Answer : preheating the boiler feed water