What is the impedance per phase of delta connected motor?

1 Answer

Answer :

1.5 times the total impedance.

Related questions

Description : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used:

Last Answer : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used: 200 NM

Description : In a three-phase, open-delta connected transformer, the line current is equal to _____________. A. the phase current B. three times the phase current C. the sum of any two phase currents D. the difference of any two phase currents

Last Answer : Answer: A

Description : One important difference between wye-connected and delta-connected generators is that delta connections have ____________. A. line voltages equal to the vector sum of the phase voltages B. phase voltages 90° ... C. line current equal to the phase current D. line voltage equal to the phase voltage

Last Answer : Answer: D

Description : Which of the listed figures shown in the illustration represents devices connected in a three-phase delta-delta arrangement? EL-0084 A. A B. B C. C D. D

Last Answer : Answer: A

Description : Which of the listed figures shown in the illustration represents devices connected in a three-phase delta-wye arrangement? EL-0084 A. A B. B C. C D. D

Last Answer : Answer: C

Description : Which of the listed figures shown in the illustration represents devices connected in a three-phase wye-delta arrangement? EL-0084 A. A B. B C. C D. D

Last Answer : Answer: D

Description : In a three phase transformer, if the primary side is connected in star and secondary side is connected in delta, what is the angle difference between phase voltage in the two cases. (A) delta side lags by -30°. (B) star side lags by -30°. (C) delta side leads by 30°. (D) star side leads by -30°.

Last Answer : Ans: C This is vector group and has +30° displacement. Therefore, delta side leads by +30°.

Description : An electrical component is connected across a 120 volt 60 hertz AC supply. What is the current drawn by the component if the impedance is 200 ohms? A. 0.01 amperes B. 0.60 amperes C. 1.67 amperes D. 100 amperes

Last Answer : Answer: B

Description : A load with an impedance of 440 ohms is connected across the secondary of the transformer illustrated. If the input voltage is 110 VAC and the step-up ratio is 10 to 1, what will be the primary current? EL-0055 A. 2.5 amps B. 25 amps C. 250 amps D. current cannot be determined with information given

Last Answer : Answer: B

Description : The transistors in the illustrated circuit are connected using what type of coupling? EL-0051 A. RC coupling B. transformer coupling C. impedance coupling D. direct coupling

Last Answer : Answer: D

Description : The transistors in the illustrated circuit are connected using what type of coupling? EL-0050 A. RC coupling B. transformer coupling C. Impedance coupling D. direct coupling

Last Answer : Answer: C

Description : A load with an impedance of 440 ohms is connected across the secondary of the device illustrated. If the input voltage is 110 VAC and the step-up ratio is 10 to 1, what will be the primary current? EL-0055 A. 2.5 amps B. 25 amps C. 250 amps D. current cannot be determined with information given

Last Answer : Answer: B

Description : In a capacitor start single-phase induction motor, the capacitor is connected (A) in series with main winding. (B) in series with auxiliary winding. (C) in series with both the windings. (D) in parallel with auxiliary winding.

Last Answer : Ans: B To make single phase motor self start. We split the phases at 90 degree. Hence, motor behaves like a two phase motor.

Description : An induction motor having full load torque of 60 Nm when delta connected develops a starting torque of 120 Nm. For the same supply voltage if the motor is changed to star connection, the starting torque developed will be  A) 40 Nm B) 60 Nm C) 90 Nm D) 120 Nm

Last Answer : An induction motor having full load torque of 60 Nm when delta connected develops a starting torque of 120 Nm. For the same supply voltage if the motor is changed to star connection, the starting torque developed will be 40 Nm

Description : A three-phase transformer, connected in star-delta, is composed of three single-phase transformers, each rated 127/ 13.2 kV. The line-to-line voltage ratio for the three-phase transformer is: A) 220 / 13.2 kV B) 127 / 13.2 kV C) 127 / 220 kV D) 220 / 220 kV

Last Answer : A three-phase transformer, connected in star-delta, is composed of three single-phase transformers, each rated 127/ 13.2 kV. The line-to-line voltage ratio for the three-phase transformer is: 220 / 13.2 kV 

Description : Two single-phase 150 kVA, 7200/ 600 volt transformers are connected in open-delta. The maximum three-phase load that they can carry is: A) 300 kVA B) 75 kVA C) 259 kVA D) 249 kVA

Last Answer : Two single-phase 150 kVA, 7200/ 600 volt transformers are connected in open-delta. The maximum three-phase load that they can carry is:  259 kVA

Description : A 4000 kVA, 11 kV/132 kV delta-star connected 3-phase transformer has reactance, x1 = 0.12 p.u. The actual value of x1 referred to the low voltage side is (A) 0.85 Ω (B) 3.63 Ω (C) 36.3 Ω (D) 252 Ω

Last Answer : A 4000 kVA, 11 kV/132 kV delta-star connected 3-phase transformer has reactance, x1 = 0.12 p.u. The actual value of x1 referred to the low voltage side is 3.63 Ω

Description : The main application of delta/zig-zag connected 3-phase transformer is to supply (A) balanced loads (B) unbalanced loads (C) furnace loads (D) single-phase loads

Last Answer : The main application of delta/zig-zag connected 3-phase transformer is to supply unbalanced loads

Description : Three equal impedances are first connected in delta across a 3 -phase balanced supply. If the same impedances are connected in star across the same supply then,

Last Answer : A

Description : Explain Three Phase Bidirectional Delta Connected Controller.

Last Answer : Three Phase Bidirectional Delta Connected Controller:

Description : If P is the power of a star connected system then what will be power of an equivalent delta connected system? A..P B. 3P C. P/3 D. None of the above

Last Answer : Ans: A

Description : Current measuring instruments must always be connected in _____________. A. series with a circuit B. parallel with a circuit C. series-parallel with a circuit D. delta with the shunt

Last Answer : Answer: A

Description : The power supplied to a motor is six kilowatts at 120 volts. What is the impedance of the motor? A. 0.05 Ohms B. 0.50 Ohms C. 2.40 Ohms D. 24.00 Ohms

Last Answer : Answer: C

Description : An electrical connection between the wiring of an electric motor and its metal frame is known as a/an _____________. A. eddy current B. ground C. impedance D. flux leakage

Last Answer : Answer: B

Description : Most three-phase induction motors used for driving engine room auxiliaries are started by _____________. A. resistor starters B. across-the-line starters C. impedance starters D. reactor starters

Last Answer : Answer: B

Description : Draw and explain star delta starter for 3 phase induction motor

Last Answer : Star Delta Starter for 3 Phase Induction Motor:  Diagram Explanation: The stator winding of the motor which is designed for delta operation is connected in star during starting ... which connects stator windings in delta connection. Now each stator phase gets full line voltage VL.

Description : Describe the power and control circuit for automatic Star-Delta starter for 3-phase induction motor.

Last Answer : Power circuit: Control circuit: 

Description : Consider the following statements: Star delta starter is used in 3-phase induction motor because it  1. Prevents heating of the motor winding  2. Ensures permissible minimum starting current  3. Is regulated by electricity ... and 4 are correct (c) 1, 3 and 4 are correct (d) 1 and 2 are correct 

Last Answer : Consider the following statements: Star delta starter is used in 3-phase induction motor because it  1. Prevents heating of the motor winding  2. Ensures permissible minimum starting current  3. Is regulated by ... and 4 are correct (c) 1, 3 and 4 are correct (d) 1 and 2 are correct 

Description : Disadvantages of Star-Delta Starting of Induction motor?

Last Answer : In Star-Delta starting induction motor stator is connected in star connection for starting after picking up speed it is connected to delta connection. When induction motor is connected in star connection ... . This also results in reduced starting torque (1/3 times compared to delta connection).

Description : What are the advantages of star-delta starter with induction motor?

Last Answer : The main advantage of using the star delta starter is reduction of current during the starting of the motor. Starting current is reduced to 3-4 times of current of Direct online starting Hence the starting current is reduced , the voltage drops during the starting of motor in systems are reduced

Description : Why star delta starter is preferred with induction motor?

Last Answer : Star delta starter is preferred with induction motor due to following reasons: Starting current is reduced 3-4 times of the direct current due to which voltage drops and hence it causes less ... caused. In addition, starting torque is increased and it prevents the damage of motor winding.

Description : Which of the following procedures should be used to determine the load of a threephase, delta wound, AC generator? A. Multiply the amperage in one phase by three. B. Divide the total amperage in all ... square root of three. D. Divide the total amperage in all phases by the square root of three.

Last Answer : Answer: C

Description : In testing a three-phase delta winding for an open circuit using a megohmmeter, you must ______________. A. test each phase with all connections intact B. measure the voltage across the open ... groups to avoid short circuiting D. open the delta-connections to avoid shunting the phase being tested

Last Answer : Answer: D

Description : Two transformers of identical voltages but different capacities are operated in parallel, for satisfactory load sharing: a) Impedances should be equal b) Per unit impedance must be equal c) per unit impedance and X/R ratio must be equal d) Impedance and X/R ratio must be equal

Last Answer : Ans: C

Description : Two transformers operating in parallel will share the load depending upon their (A) Rating. (B) Leakage reactance. (C) Efficiency. (D) Per-unit impedance.

Last Answer : Ans: A Transformers having higher kVA rating will share more load.

Description : A final amplifier of a radio transmitter draws 250 mA of plate current when the plate supply voltage is 1400 volts. If the plate circuit efficiency is 80% and the transmitter is connected to an antenna having a feed impedance of 70 ohms, ... at the feed-point? A. 4.0 A B. 2.2 A C. 1.25 A D. 2.0 A

Last Answer : D. 2.0 A

Description : Calculate the noise figure of the receiver whose RF amplifier has an input resistance of 1000Ω and an equivalent shot-noise resistance of 2000Ω, a gain of 25 and load resistance of 125 kΩ. Given that the bandwidth is 1. ... to an antenna with an impedance of 75Ω. A. 30.3 B. 3.03 C. 303 D. .303

Last Answer : A. 30.3

Description : Transmission lines when connected to antenna have A. capacitive load B. resistive load whose resistance is less than characteristics impedance C. resistive load at the resonant frequency D. resistive load whose resistance is greater than the characteristic impedance of the line

Last Answer : C. resistive load at the resonant frequency

Description : Termination means A. result of disconnecting a line from a transmitter B. result of cutting both ends of a conductor C. looking back impedance of a line with no load D. load connected to the output end of a transmission line

Last Answer : D. load connected to the output end of a transmission line

Description : Find the standing wave ratio, when a load impedance of 250 ohm is connected to a 75 ohm line. a) 0.3 b) 75 c) 250 d) 3.33

Last Answer : d) 3.33

Description : What will be the reflection coefficient of the wave of load connected to transmission line if surge impedance of the line is equal to load ? (a) Zero (b) Unity (c) Infinity (d) None of the above

Last Answer : (a) Zero

Description : In a load flow analysis of a power system, the load connected at a bus is represented as a) Constant current drawn from the bus b) Constant impedance connected at the bus c) Voltage and frequency dependent sources at the boss d) Constant real and reactive power drawn from the bus

Last Answer : d) Constant real and reactive power drawn from the bus

Description : [75] Two transformers are connected in parallel. These transformers do not have equal percentage impedance which results A. Short-circuiting of the secondaries B. Power factor of one of the ... have negligible core losses D. Loading of the transformers not in proportion to their kVA ratings.

Last Answer : D. Loading of the transformers not in proportion to their kVA ratings

Description : A load of 200 ohm is used to match 300 ohm transmission line to achieve SWR=1. Find out the required characteristic impedance of a quarter of a quarter wave transformer connected directly to the load.

Last Answer : Solution :

Description : Two transformers having the same p.u. impedance connected in parallel share the connected load (A) equally (B) in proportion to the respective ratings (C) in proportion to the voltage ratio (D) in proportion to the zero phase displacement

Last Answer : Two transformers having the same p.u. impedance connected in parallel share the connected load in proportion to the respective ratings

Description : A three phase, salient pole synchronous motor is connected to an infinite bus. It is operated at no load a normal excitation. The field excitation of the motor is first reduced to zero ... First increases and then decreases steeply (C) First decreases and then increases steeply (D) Remains constant

Last Answer : B

Description : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor ... Hz supply is  (A) 58.5 A (B) 45.0 A (C) 42.7 A (D) 55.6 A

Last Answer : The locked rotor current in a 3-phase, star connected 15 , kW 4 , pole 230 V , 50 Hz induction motor at rated conditions is 50 A. Neglecting losses and magnetizing current, the approximate locked rotor line current drawn when the motor is connected to a 236 , V 57 Hz supply is 45.0 A 

Description : A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be

Last Answer : Leading

Description : The maximum possible power of a 3-phase synchronous motor with synchronous reactance 0.8 p.u. connected to a bus-bar of 1.0 p.u. and excitation adjusted to 1.2 p.u. is (A) 0.5 p.u. (B) 0.96 p.u. (C) 1.5 p.u. (D) 1.8 p.u.

Last Answer : The maximum possible power of a 3-phase synchronous motor with synchronous reactance 0.8 p.u. connected to a bus-bar of 1.0 p.u. and excitation adjusted to 1.2 p.u. is 1.5 p.u.

Description : A 3~phase synchronous motor, connected to infinite bus, is operating at no load at normal excitation. The field excitation of the motor is first decreased to zero and then increased in the ... 2) First decrease and then increase, (3) Increases continuously (4) First increase and then decreased

Last Answer : A 3~phase synchronous motor, connected to infinite bus, is operating at no load at normal excitation. The field excitation of the motor is first decreased to zero and then increased in the reverse direction. The armature current of the synchronous motor will: Increases continuously.