The main application of delta/zig-zag connected 3-phase transformer is to supply

(A) balanced loads (B) unbalanced loads

(C) furnace loads (D) single-phase loads

1 Answer

Answer :

The main application of delta/zig-zag connected 3-phase transformer is to supply unbalanced loads

Related questions

Description : WHAT is ZIG ZAG Grounding Transformer

Last Answer : ANSWER: Three Single Phase Transformers can be connected to have a three phase Zig Zag Transformer. This system can be used for either grounding or developing a fourth WIRE from a three phase neutral. An example ... - three phase - three wire system to a 480Y/277 V - three phase - four wire system

Description : What are Zig Zag Wraps made out of?

Last Answer : answer: Each of the Zig-Zag Blunt Wraps come individually wrapped in a Resealable Foil Packaging. There are 2 Blunts Rolls/Pack, each made in Dominican Republic with the finest Zig-Zag Quality approved ... , soaked in a chemical that gives you a kind of brain damage that makes you taste apples.

Description : In part programming, interpolation is used for obtaining trajectory. a.helicoidal b.pentagonal c.triangular d.zig-zag

Last Answer : a.helicoidal

Description : Which of the following statement is false? a.The potential energy of a particle has the form Ep = k2x. The force acting on the particle is constant (k is a constant) b.The linear velocity of ... zag path while ascending a steep hill e.The density of milk decreases when cream is taken out of milk

Last Answer : e. The density of milk decreases when cream is taken out of milk

Description : Does the Brother CS6000i have a zig zag feature?

Last Answer : Yes, the Brother CS6000i features a zig zag stitch, and is even capable of an extra wide 7mm zig zag pattern!

Description : Who can tell me online store outlet that sells zig zag running shoes?

Last Answer : You can easily buy Zig Zag running shoes online directly from the Reebok website. They are also available for sale on www.Amazon.com and www.jjbsports.com

Description : Path followed by water jet issuing from the bottom of a water tank will be a (A) Parabola (vertex being at the opening) (B) Hyperbola (C) Horizontal straight line (D) Zig-zag path (which is geometrically undefined)

Last Answer : (A) Parabola (vertex being at the opening)

Description : If the rivets in adjacent rows are staggered and outermost row has only one rivet, the arrangement of the rivets, is called (A) Chain riveting (B) Zig-zag riveting (C) Diamond riveting (D) None of these

Last Answer : (C) Diamond riveting

Description : What is the maximum number of open bays if transverse zig zag bracing is installed along the width of a birdcage scaffold? a. Four b. Three c. Five d. Six

Last Answer : b. Three

Description : At what angle must zig zag bracing be installed? a. 35-55 degree b. 35-60 degree c. 25-45 degree d. 35-70 degree

Last Answer : a. 35-55 degree

Description : A hiker stands at the bottom of steep hill. The hiker may follow a straight line path to the top of the hill, a distance of 300 feet, or she may follow a zig-zag path to the top of the hill and walk a ... times the work going along the straight path? Is it: w) equal x) twice y) 4 times z) 8 times?

Last Answer : ANSWER: W -- EQUAL 

Description : Three equal impedances are first connected in delta across a 3 -phase balanced supply. If the same impedances are connected in star across the same supply then,

Last Answer : A

Description : for Delta-Star connection of 3-phase transformer: i) Draw the connection diagram ii) List any two advantages of this connection iii) State its area of application. 

Last Answer : Disadvantages: i) In this type of connection, the secondary voltage is not in phase with the primary. Hence it is not possible to operate this connection in parallel with star-star or delta-delta ... iv) As line current is equal to phase current the conductor size of winding should be large. 

Description : In a three-phase, open-delta connected transformer, the line current is equal to _____________. A. the phase current B. three times the phase current C. the sum of any two phase currents D. the difference of any two phase currents

Last Answer : Answer: A

Description : In a three phase transformer, if the primary side is connected in star and secondary side is connected in delta, what is the angle difference between phase voltage in the two cases. (A) delta side lags by -30°. (B) star side lags by -30°. (C) delta side leads by 30°. (D) star side leads by -30°.

Last Answer : Ans: C This is vector group and has +30° displacement. Therefore, delta side leads by +30°.

Description : A three-phase transformer, connected in star-delta, is composed of three single-phase transformers, each rated 127/ 13.2 kV. The line-to-line voltage ratio for the three-phase transformer is: A) 220 / 13.2 kV B) 127 / 13.2 kV C) 127 / 220 kV D) 220 / 220 kV

Last Answer : A three-phase transformer, connected in star-delta, is composed of three single-phase transformers, each rated 127/ 13.2 kV. The line-to-line voltage ratio for the three-phase transformer is: 220 / 13.2 kV 

Description : A 4000 kVA, 11 kV/132 kV delta-star connected 3-phase transformer has reactance, x1 = 0.12 p.u. The actual value of x1 referred to the low voltage side is (A) 0.85 Ω (B) 3.63 Ω (C) 36.3 Ω (D) 252 Ω

Last Answer : A 4000 kVA, 11 kV/132 kV delta-star connected 3-phase transformer has reactance, x1 = 0.12 p.u. The actual value of x1 referred to the low voltage side is 3.63 Ω

Last Answer : Advantages of open delta connection of 3-phase transformer:  1. When one of the phase in case of delta-delta bank is out of order by any reason, the service will be continued till ... demand in future (about 33%) will be supplied by converting open delta connection to delta-delta connection.

Description : What will happen if the primary of a transformer is connected to D.C. supply?  (A) Transformer will operate with low efficiency (B) Transformer will operate with high efficiency (C) No effect (D) Transformer may start to smoke and burn 

Last Answer : What will happen if the primary of a transformer is connected to D.C. supply?  (A) Transformer will operate with low efficiency (B) Transformer will operate with high efficiency (C) No effect (D) Transformer may start to smoke and burn 

Description : In conversion of 3-phase to 2-phase supply with T connection, the transformation ratio of the teaser will be__ times to that of main transformer: a) 1.732 b) 1.15 c) 0.866 d) Unity

Last Answer : Ans: C

Description : One important difference between wye-connected and delta-connected generators is that delta connections have ____________. A. line voltages equal to the vector sum of the phase voltages B. phase voltages 90° ... C. line current equal to the phase current D. line voltage equal to the phase voltage

Last Answer : Answer: D

Description : Which of the listed figures shown in the illustration represents devices connected in a three-phase delta-delta arrangement? EL-0084 A. A B. B C. C D. D

Last Answer : Answer: A

Description : Which of the listed figures shown in the illustration represents devices connected in a three-phase delta-wye arrangement? EL-0084 A. A B. B C. C D. D

Last Answer : Answer: C

Description : Which of the listed figures shown in the illustration represents devices connected in a three-phase wye-delta arrangement? EL-0084 A. A B. B C. C D. D

Last Answer : Answer: D

Description : What is the impedance per phase of delta connected motor?

Last Answer : 1.5 times the total impedance.

Description : Two single-phase 150 kVA, 7200/ 600 volt transformers are connected in open-delta. The maximum three-phase load that they can carry is: A) 300 kVA B) 75 kVA C) 259 kVA D) 249 kVA

Last Answer : Two single-phase 150 kVA, 7200/ 600 volt transformers are connected in open-delta. The maximum three-phase load that they can carry is:  259 kVA

Description : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used:

Last Answer : A 3-phase delta connected squirrel cage induction motor when started with a DOL starter has a starting torque of 600 NM. Its starting torque when star delta starter is used: 200 NM

Description : Explain Three Phase Bidirectional Delta Connected Controller.

Last Answer : Three Phase Bidirectional Delta Connected Controller:

Description : 52 A transformer has 1000 primary turns, connected to 250V ac supply. To get 400V secondary voltage the no of secondary turns should be A. 1600 B. 250 C. 400 D. 1250

Last Answer : A. 1600

Description : Three resistances of 3 Ω each are connected in delta. The value of the resistances in the equivalent star is : (A) 27 (B) 9 (C) 1.5 (D) 1 Ω

Last Answer : 9

Description : Zig Ziglar Famous Motivational And Inspirational Quotes

Last Answer : 1. You are the only person on earth who can use your ability. 2. When you put faith, hope and love together, you can raise positive kids in a negative world.  3. There has never been a ... in your entire arsenal is integrity.  27. Expect the best. Prepare for the worst. Capitalize on what comes.

Description : What is the supply rated o/p if two single phase transformer connect to give three phase o/p from a three phase I/p?

Last Answer : A. Each transformer is only capable of supplying 86.6%of its o/p rating

Description : A 220/440 V, 50 Hz, 5 KVA, single phase transformer operates on 220V, 40Hz supply with secondary winding open circuited. Then (A) Both eddy current and hysteresis losses decreases. (B) Both ... same but hysteresis loss increases. (D) Eddy current loss increases but hysteresis loss remains the same.

Last Answer : (A) Both eddy current and hysteresis losses decreases.

Description : A single phase transformer is designed to operate from 50 Hz, 1100 V supply and to have an output voltage of 240 V at no load. The core has mean area of 30 cm2 and the flux density has not to exceed 1.3T. The number of secondary turns will be (a) 1270 (b) 1017 (c) 768 (d) 277  

Last Answer : E2=e2=4.44*flux*N2*f=240 V Flux=Flux density* Area Area=30 cm2  =30*10-4 m2 Flux= 1.3*30*10-4  Wb=39*10-4 Wb E=240= 4.44*39*10-4 *N2*50      N2=277.

Description : If a 220/440 V, 50 Hz, 5 KVA, single-phase transformer operates on 220V, 40Hz supply with secondary winding open circuited: (A) both the eddy current and the hysteresis losses will decrease ... losses will increase (D) eddy current losses will increase but the hysteresis losses will remain the same

Last Answer : If a 220/440 V, 50 Hz, 5 KVA, single-phase transformer operates on 220V, 40Hz supply with secondary winding open circuited: both the eddy current and the hysteresis losses will decrease

Description : A single-phase transformer has a turns ratio of 1 :2 and is connected to a purely resistive load as shown in the figure. The magnetizing current drawn is 1A, and the secondary current is 1A. Ifcore losses and ... reactances are neglected, the primary current is  A)1.41A B)2A C) 2.24A D)3A

Last Answer : A single-phase transformer has a turns ratio of 1 :2 and is connected to a purely resistive load as shown in the figure. The magnetizing current drawn is 1A, and the secondary current is 1A. Ifcore losses and leakage reactances are neglected, the primary current is 2.24A

Description : In a three phase transformer, if the primary side is connected in star and secondary side is connected in delta, the angle difference between phase voltage in the two cases will be: (A) delta side will lag by -30° ... will lag by -30° (C) delta side will lead by 30° (D) star side will lead by -30°

Last Answer : In a three phase transformer, if the primary side is connected in star and secondary side is connected in delta, the angle difference between phase voltage in the two cases will be: delta side will lead by 30° 

Description : Figure 'D' of the diagram shown in the illustration has a turns ratio of four to one. If a three-phase 440 volt supply is connected to terminals 'A-B-C', what voltage should develop across terminals 'a-b-c'? EL-0084 A. 64 volts B. 110 volts C. 190 volts D. 762 volts

Last Answer : Answer: A

Description : Figure 'C' of the diagram shown in the illustration has a turns ratio of four to one. If a three-phase 440 volt supply is connected to terminals 'A-B-C', what voltage should develop across terminals 'a-b-c'? EL-0084 A. 64 volts B. 110 volts C. 190 volts D. 762 volts

Last Answer : Answer: C

Description : Figure 'B' of the diagram shown in the illustration has a turns ratio of four to one. If a three-phase 440 volt supply is connected to terminals 'A-B-C', what voltage should develop across terminals 'a-b-c'? EL-0084 A. 64 volts B. 110 volts C. 190 volts D. 762 volts

Last Answer : Answer: B

Description : Figure 'A' of the diagram shown in the illustration has a turns ratio of four to one. If a three-phase 440 volt supply is connected to terminals 'A-B-C', what voltage should develop across terminals 'a-b-c'? EL-0084 A. 64 volts B. 110 volts C. 190 volts D. 762 volts

Last Answer : Answer: B

Description : Describe the power and control circuit for automatic Star-Delta starter for 3-phase induction motor.

Last Answer : Power circuit: Control circuit: 

Description : Consider the following statements regarding three-phase transformers in Open -Delta (V -V) connections :  1. Being a temporary remedy when one transformer forms of Delta -Delta system is &imaged, and removed from service.  ... and 2 only (b) 1 and 3 only (c) 2 and 3 only (d) 1, 2 and 3

Last Answer : Consider the following statements regarding three-phase transformers in Open -Delta (V -V) connections :  1. Being a temporary remedy when one transformer forms of Delta -Delta system is &imaged, and removed from service.  ... and 2 only (b) 1 and 3 only (c) 2 and 3 only (d) 1, 2 and 3

Description : In a three-phase, squirrel-cage type, induction motor the rotating magnetic field is established by the _____________. A. current induced in the rotor windings B. application of a three-phase voltage ... caused by the induced current in the squirrel-cage bars with the magnetic field of the stator

Last Answer : Answer: B

Description : Explain with the neat circuit diagram only the scott connection scheme for conversion of three phase supply to two phase supply. Name one application of the same.

Last Answer : Three-phase to Two-phase Transformation (Scott Connection of Transformers): Working: i) Scott connection can be used for three-phase to two-phase conversion using two single-phase transformers ... a 3-phase system with a two-phase system with the flow of power in either direction. 

Description : The electrical schematic illustrated in figure A, depicts a/an _____________. EL-0059 A. autotransformer B. Delta Wye transformer C. primary EMF generator D. potential transformer

Last Answer : Answer: D

Description : What is the difference between delta-delta, delta-star transformer?

Last Answer : A. Delta-delta transformer is used at generating station or a receiving station for Change of Voltage (i,e) generally it is used where the Voltage is high & Current is low whereas Delta-star ... star neutral is taken as a return path and this configuration is used for Step down voltage phenomena.

Description : Why Delta Star transformer Are Used For Lighting Loads?

Last Answer : For lighting loads, neutral conductor is must and hence the secondary must be star winding. and this lighting load is always unbalanced in all three phases. To minimize the current unbalance in the primary we use delta winding in the primary. So delta / star trformer is used for lighting loads.

Description : Why input transformer of PUPS module 1 is delta-delta and module 2 is delta-star?

Last Answer : With the help of this arrangement, combined DC output from both chargers is equivalent to that from a 12-pulse rectifier. Advantage of 12-pulse rectifier is that the mains current is fairly close ... phase angle difference 30-degree between module 1 output and module 2 output give 12-pulse output. 

Description : Why delta – delta CT’s are used for star – star transformer differential protection?

Last Answer : Say primary neutral is not solidly earthed. Then for any earthfault on secondary terminal, the primary current distribution is so for external fault, the differential is likely to operate if sequence current ... into relay. The 2:1:1 distribution is possibly only for core type or delta tertiary.