What are the main two divisions of MAPS electrical system and what do you understand by it? 

1 Answer

Answer :

The two main divisions of MAPS electrical system are

a. Main output system. Output system supplies power to the grid. Generated voltage is stepped up to 220 kV from 16.5 kV and supplied to grid.

b. Station service system. This system supplies the load inside the power station. The generated voltage is stepped down to 6.6 kV and 415 V from 16.5 kV and supplies to auxiliary loads. 

Related questions

Description : In MAPS Unit # 1 end-shield cooling system has got heaters. Why?

Last Answer : Unit # 1 end-shield is made of nickel steel, which had a nil ductility temperature of -100°C while commissioning. After 30 years of operation this will rise to +32°C, because of radiation exposure. ... #2 this problem is not existed because in this unit end-shields are made up of stainless steel. 

Description : A CRO screen has ten divisions on the horizontal scale. If a voltage signal 5 sin 314t+45 deg)is examined with a line base settings of 5 msec/div, the number of cycles of signal displayed on the screen will be a) 0.5 cycles b) 2.5 cycles c) 5 cycles d) 10 cycles

Last Answer : Ans: 2.5 cycles

Description : Why indoor switchyard is provided in MAPS?  

Last Answer : The salt contamination in the switchyard is avoided by providing indoor switchyard in MAPS. Because the plant is just 300 metres away from the seashore and the atmosphere is saline. This salt will get ... and to have low cost of installation and spare parts of aluminium indoor switchyard is used. 

Description : A ground is indicated by the ground-detecting system on the main electrical switchboard. The FIRST step in locating the actual ground is to _____________. A. close all circuit breakers in ... ground detection system indicates normal C. change over generators D. check each circuit with a megohmmeter

Last Answer : Answer: B

Description : The part of the shipboard electrical system used to control the distribution of power to the branch circuits, is the _____________. A. bridge control panel B. disconnect links C. governor relay box D. main switchboard

Last Answer : Answer: D

Description : The main scale of a vernier callipers has n divisions/cm. n divisions of the vernier scale coincide with (n – 1) divisions of main scale.

Last Answer : The main scale of a vernier callipers has n divisions/cm. n divisions of the vernier scale coincide with (n - 1) ... n}\) (D) \(\frac{1}{n^2}\)

Description : What main divisions of a play are called?

Last Answer : ddd

Description : What main divisions of a play are called?

Last Answer : ddd

Description : The least count of a Vernier scale is  (A) Sum of the smallest divisions of main and Vernier scales  (B) Value of one division of the primary scale divided by total number of divisions ... division of Vernier scale divided by total number of divisions of primary scale  (D) None of these 

Last Answer : (B) Value of one division of the primary scale divided by total number of divisions of Vernier  scale 

Description : The main plate of a transit is divided into 1080 equal divisions. 60 divisions of the Vernier coincide exactly with 59 divisions of the main plate. The transit can read angles accurate upto (A) 5" (B) 10" (C) 15" (D) 20"

Last Answer : (D) 20"

Description : The two main categories of maps are?

Last Answer : Political maps and Physical maps.Physical maps show the shape of the land - hills, lakes, forests, the coast and so on. Political maps show how the land is used by people - counties, provinces, countries, town boundaries, etc.

Description : To remove an alternator operating in parallel with another unit from the main electrical bus, you must FIRST _________. A. adjust the power factor on both units B. set the desired voltage on ... C. open the circuit breaker on the outgoing alternator D. remove the load from the outgoing alternator

Last Answer : Answer: D

Description : A ground in an electrical circuit outside the engine room _____________. A. cannot be detected under normal conditions B. is of no consequence to engineering personnel C. is indicated at the branch circuit breaker panel D. is indicated by the ground detecting lamps on the main switchboard

Last Answer : Answer: D

Description : Regarding an AC generator connected to the main electrical bus; as the electric load and power factor vary, a corresponding change is reflected in the generator armature reaction. These changes in ... . governor speed droop setting B. voltage regulator C. balance coil D. phase-balance relay

Last Answer : Answer: B

Description : What Is The One Main Difference Between Ups & Inverter ? And Electrical Engineering & Electronics Engineering ?

Last Answer : uninterrupted power supply is mainly use for short time .me according to ups VA it gives backup. ups is also two types : on line. offline. online ups having high volt and amp for long time backup ... but inverter is start with 2v,24,dc to 36v dc and 20amp to 80amp battery with long time backup.

Description : Help me understand the wording of this problem (electrical circuits homework)?

Last Answer : Sounds right to me.

Description : What do you understand by the units of electrical energy? How many joules of energy is consumed if the electrical meter shows 200 units of energy ? -Science

Last Answer : Unit of electrical energy is defined as the energy spent or used by electrical appliance at the rate of 1 kw For (t) hours 1 kwh = 1000 W *3600s ... = 400* 3.6*10^6 J = 144*10^7 J

Description : Name the three divisions of the human nervous system.

Last Answer : The human nervous system consists of three components namely a) Central Nervous System (CNS) b) Peripheral Nervous System (PNS) c) Autonomic Nervous System (ANS)

Description : Name the three divisions of the nervous system.

Last Answer : Nervous system consists of receptors, effectors and conductors.

Description : Which maps come standard with this GPS system?

Last Answer : TeleAtlas Maps are standard with this GPS system.

Description : What do you understand by tan delta for a insulating material?

Last Answer : Tan delta measurement is done to find the qualities of insulating material. Tan delta is angle between current due to surface leakage or current due to capacitance and the capacitive current. That is Tan δ = Ir / Ic. 

Description : What do you understand by station black out?

Last Answer : When class IV and class III power supply fails and DG’s cannot be started and also this condition prevails for 5 minutes then it is called station black out condition.  

Description : A three-phase electrical system is equipped with ground detecting lamps. If one of the lamp goes dark and the other two burn normally before and after the test switch is operated, this indicates _______________. ... of the three phases D. the voltage to the dark lamp is less than that of the system

Last Answer : Answer: A

Description : Which of the following statements is/are true regarding requirements for receptacle outlets aboard vessels? A. Each receptacle outlet operating at 100 volts or more must have a grounding pole. B. Outlets ... machinery with a portable light having a 50 foot flexible cord. D. All of the above.

Last Answer : Answer: A

Description : A diesel driven emergency generator is prevented from being paralleled with the ship's service generators by __________. A. an electrical interlock system B. an automatic paralleling trip switch C. the synchronizing oscilloscope D. the reverse current relay

Last Answer : Answer: A

Description : In a three-phase electrical system, three ground detecting lamps are provided. If all three lamps REMAIN at half-brilliance when the ground detecting test switch is operated, ______________. A. there is a ... must be replaced C. there are no grounds present D. the light bulbs are of improper voltage

Last Answer : Answer: C

Description : In a three-phase electrical system, three ground detecting lamps are provided. One lamp goes dark and the others increase in brightness. When the test button is pushed, all lamps have equal illumination. You ... C. there are grounds on the lines with the bright lamps D. this is a normal condition

Last Answer : Answer: A

Description : In an alternating current electrical system, a low system power factor is a direct sign of _____________. A. wasted energy B. efficient operation C. a short in the exciter field windings D. an excessive number of minor system grounds

Last Answer : Answer: A

Description : Accidental grounds in a shipboard electrical system must be repaired as soon as possible as they will ____________. A. result in immediate power outages B. damage circuit breakers C. appear on the ground detection system D. damage insulation and may cause outages

Last Answer : Answer: D

Description : Which of the following represents a characteristic of an ungrounded electrical distribution system? A. Accidental contact between one line and ground does not cause an outage. B. Double ground faults on ... unnecessary. D. Accidental contact between one line and ground will always cause an outage.

Last Answer : Answer: A

Description : If the illustrated motor fails to start and gives a loud hum when the start button is pushed, the problem is ________. EL-0007 A. one of the phases to the motor is not energized because of ... electrical distribution system D. 'OL1' is open because of 'T1' overload causing the motor to single phase

Last Answer : Answer: A

Description : A switchboard, for a AC electrical distribution system, will be provided with which of the following components? A. Frequency meter. B. Ammeter C. Voltmeter D. All of the above

Last Answer : Answer: D

Description : A switchboard for an AC electrical system requires the use of which of the following devices? A. Frequency meter. B. Ohmmeter. C. Induction voltage regulator. D. Current transformer governor.

Last Answer : Answer: A

Description : How the electrical power system protection is divided?

Last Answer : The overall system protection is divided into • Generator protection • Transformer protection • Busbar protection • Transmission line protection and • Feeder protection

Description : What is the difference between 3 phase 3 wire & 3 phase 4 wire system in electrical system?

Last Answer : The answer is very simple. A 3-phase 3-wire system does not contain a neutral. This occurs when you have 3-phase loads such as motors that do not require a neutral. A 3-phase 4-wire system has a neutral. A ... enough in HV side - .In utility point 4 ( 230 , 380 or 415 V)wire required in LV side.

Description : How harmonics generated in electrical power distribution system?

Last Answer : Harmonic frequencies are integral multiples of the fundamental supply frequency, i.e. for a fundamental of 50 Hz, the third harmonic would be 150 Hz and the fifth harmonic would be 250 ... the corresponding application guides, since the electricity grid's protection system should cut off the fault.

Description : State the factors, for the choice of electrical system for an aero turbine.

Last Answer : A:The choice of electrical system for an aero turbine is guided by three factors: Type of electrical output: dc, variable- frequency ac, and constant- frequency ac. Aero turbine ... energy output: in conjunction with battery or other form of storage, or interconnection with power grid.

Description : What are the design guidelines for electrical system?

Last Answer : a. All safety related equipments are in control building, SRPH and are designed for SSE conditions. As per studies seismic condition is not there within 5 kms and nearest zone is away from ... operating island. h. To reduce fault level in lighting circuits separate 280-kVA transformer is provided.

Description : What are the design objectives of Electrical System?

Last Answer : a. To evacuate generated electrical power. b. To provide required power to SUT, UT, DG, UPS, and CUPS. c. To provide required emergency power from onsite DG, UPS & CUPS. ... earthing, and personnel protection. m. To provide necessary electrical and physical isolation of electrical equipments. 

Description : What are the advantages of VSCF wind electrical system?

Last Answer : Advantages of VSCF wind electrical system are: No complex pitch changing mechanism is needed. Aero turbine always operates at maximum efficiency point. Extra energy in the high ... extracted Significant reduction in aerodynamic stresses, which are associated with constant - speed operation.

Description : State the factors, for the choice of electrical system for an aero turbine.

Last Answer : The choice of electrical system for an aero turbine is guided by three factors: Type of electrical output: dc, variablefrequency ac, and constant- frequency ac. Aero turbine rotational speed ... output: in conjunction with battery or other form of storage, or interconnection with power grid.

Description : Name the two major physical divisions formed by the Trans-antarctic mountain. -Geography

Last Answer : It divides Antarctica into two major physical divisions 1. East Antarctica 2. West Antarctica

Description : Name any two physical divisions of India and state two characteristic features of each. -Geography

Last Answer : Himalayas and Peninsular Plateau are the two physical divisions of India : Himalayas 1. It is a young fold mountain of soft rocks. 2. Most of the rocks are sedimentary. 3. Himalayas are ... -moving and are of low gradients with shallow river valleys. 4. It was formed during Precambrian era.

Description : How do social divisions affect politics ? Give two examples. -SST 10th

Last Answer : Social divisions affect politics both in negative as well as positive way. These are: Negative impact: In a democratic country like India there is competition between various ... due representation of various communities and policies to redress the grievances of disadvantaged communities.

Description : What could be the two possible outcomes of politics of social divisions ? -SST 10th

Last Answer : The two outcomes are : (i) Political divisions could lead to violence and disintegration of a country. Example : Yugoslavia. (ii) They could be amicably settled in a democracy where rulers share ... as nationalists and then as belonging to a religious or ethnic or linguistic group. Example : India.

Description : “Some people conclude that politics and social divisions should not be allowed to mix.” Support this idea with two arguments. -SST 10th

Last Answer : It is true that politics and social divisions should not be allowed to mix. It leads to negative results. We can see this when caste starts influencing politics - (i) Each caste group tries ... because it gives the impression that elections are about castes and nothing else. This is far from true.

Description : Suggest any two measures to check the social divisions -SST 10th

Last Answer : Two measures to check the social division : 1. Abolition of untouchability in society. 2. Reservations of seats in educational institutions and government jobs for the weaker sections of society. Hope this helps!

Description : What are the two mains divisions of the chordate phylum?

Last Answer : Chordates are divided into protochordates (cephalochordates and urochordates) and vertebrates. Life Kingdoms Review - Image Diversity: invertebrates vertebrates

Description : How many divisions are there in CIBIL? A. one B. Two C. Three D. Four E. None of the Above

Last Answer : B. Two Explanation: It has two divisions : Consumer Bureau and Commercial Bureau