Why auto transfer is prevented if the backup protection is operated?  

1 Answer

Answer :

The back up protection is supposed to operate in case of a bus fault. Hence the auto transfer is prevented. 

Related questions

Description : Why auto transfer is blocked for back up protection?

Last Answer : Because Backup protection operates normally for bus faults. All main protections are generally operating for internal faults therefore there is no point in restoring the power supply through auto transfer when there is a bus fault existing. 

Description : What is the backup protection available for an alternator?

Last Answer : Overcurrent and earth fault protection is the backup protections.

Description : Galvanic corrosion cannot be prevented by (A) Cathodic protection (B) Anodic protection (C) Usage of largest possible anodic area (D) Any one of these

Last Answer : Option B

Description : The type of backup protection scheme widely used in the field is (A) Relay backup (B) Breaker backup (C) Remote backup (D) Auxiliary backup

Last Answer : The type of backup protection scheme widely used in the field is Remote backup 

Last Answer : Discrimination between main and back up protection is provided by the use of relays which are slow.

Description : Primary and Backup Protection

Last Answer : Primary and Backup Protection  B,D,G,I are the primary protection. A,C,H,J are the backup protection. About 90% of faults are clear by Primary Protection. So ... ordinated backup (primary is at various station  and backup is at control room with computer)

Description : The purpose of the automatic bus transfer shown in the illustration is to ___________. EL-0014 A. stepdown voltage to the lighting distribution panel B. provide emergency power to ... emergency switchboard from the main switchboard D. provide overcurrent protection to the lighting distribution panel

Last Answer : Answer: B

Description : What are the conditions for Auto transfer scheme?

Last Answer : Backup protections are not allowed to initiate the Auto transfer. Because under voltage may exist in the bus. Similarly protection in LV of the transformers are not initiating the Auto transfer scheme. There are three metrics used ... in GT. 4. Fault in 220 kV bus (SUT). 5. Fault in SUT (86M).  

Description : What are the types Auto transfer scheme?

Last Answer : 1. Fast transfer scheme to close the tie-breaker in less than 200 milli seconds. This limits transient current and voltage dip in the bus and does quick acceleration of the motors. 2. Slow transfer after 200 milli seconds.  

Description : What does auto transfer mean? 

Last Answer : If one of the sources is tripped on main protection its breaker will be tripped and the tie-breaker will close. This transfer of supply from one source to other source is called auto transfer. To restore the class IV whenever the UT or SUT is lost Auto transfer is provided.

Description : When auto transfer is effected? 

Last Answer : a) When any one module trips b) When overload exceeds 175% for more than 40 msec. is existing. c) When UPS output voltage varies beyond 415v +/- 10% 

Description : A diesel driven emergency generator is prevented from being paralleled with the ship's service generators by __________. A. an electrical interlock system B. an automatic paralleling trip switch C. the synchronizing oscilloscope D. the reverse current relay

Last Answer : Answer: A

Description : Why is it a good practice to have the frequency of the incoming alternator adjusted slightly higher than that of the loaded alternator when paralleling two alternators? A. This allows the oncoming machine to ... line. C. The reverse power relay is prevented from activating. D. All of the above.

Last Answer : Answer: D

Description : The arc resulting from the tripping of a circuit breaker is prevented from damaging the contacts by _____________. A. designing the contacts to open slowly B. directing the arc into an ... an inverse timed thermal trip for short circuit currents D. instantaneous magnetic trip for overload currents

Last Answer : Answer: B

Description : A generator is prevented from becoming motorized by the use of a/an _____________. A. overspeed trip B. reverse power relay C. back pressure trip D. governor controls

Last Answer : Answer: B

Description : Burning of controller contacts, when opening, is prevented by _____________. A. coating the contact surfaces lightly with petroleum jelly B. magnetic blowout coils C. an overvoltage release D. an overcurrent release

Last Answer : Answer: B

Description : How carona discharge is prevented in generator insulation?

Last Answer : To prevent carona discharges between insulation and the wall of the slot, the insulation in slot portion is coated with semi conducting varnish. This eliminates the formation of creepage sparks during operation and during HV test. 

Description : How moisture entry is prevented into bus duct?  

Last Answer : Silicagel breathers at either end. 

Description : Why motoring should be prevented in TG and DG? 

Last Answer : In TG motoring prevented due to the turbine limitation otherwise last stage blade will fails. In DG motoring prevented, because of unburned fuel catches fire in DG. 

Description : Choose the wrong statement (a) Temperature of medium being cooled must be below that of the evaporator (b) Refrigerant leaves the condenser as liquid (c) All solar thermally operated absorption systems are capable only of intermittent operation (d) frost on evaporator reduces heat transfer

Last Answer : Ans: a

Description : An 800 kV transmission line has a maximum power transfer capacity of P. If it is operated at 400 kV with the series reactance unchanged, the new maximum power transfer capacity is approximately (A) P (B) 2P (C) P / 2 (D) P / 4

Last Answer : An 800 kV transmission line has a maximum power transfer capacity of P. If it is operated at 400 kV with the series reactance unchanged, the new maximum power transfer capacity is approximately P / 4

Description : How should I backup my files to transfer from my old laptop to my new one?

Last Answer : Buy an external hard drive. You can get one with the space you need probably for under 50 dollars. It can serve as a backup drive, too.

Description : Is it possible to extract a Windows Easy Transfer backup without restoring it?

Last Answer : It should be.

Description : How do i transfer albums from my backup drive to itunes on my new PC?

Last Answer : Before you move anything, you need to consolidate the library (File-Library-Consolidate Library). THEN you need to move your iTunes folder to the other drive, including the iTunes Library.itl and .xml files ... songs back into iTunes. i just did this on Sunday. let me know if you have more questions

Description : Two transformers of identical voltages but different capacities are operated in parallel, for satisfactory load sharing: a) Impedances should be equal b) Per unit impedance must be equal c) per unit impedance and X/R ratio must be equal d) Impedance and X/R ratio must be equal

Last Answer : Ans: C

Description : Which of the following is/are true concerning electric power operated watertight door systems? A. Each motor driven door must use the main bus as its source of power. B. Each distribution panel for ... to permit quick activation of the system. D. Each system must have a separate branch circuit.

Last Answer : Answer: D

Description : In accordance with Coast Guard Regulations (46 CFR), each battery operated relay-controlled lantern must _____________. A. be readily portable B. contain a dry cell battery having a minimum capacity of ... automatic battery charger to maintain the battery in a fully charged state D. all of the above

Last Answer : Answer: C

Description : According to Coast Guard Regulations (46 CFR), which of the following systems must be arranged so as to be energized by the final emergency power source? A. at least one light in the ... operated watertight door system C. each charging panel for temporary emergency batteries D. all of the above

Last Answer : Answer: D

Description : A three-phase electrical system is equipped with ground detecting lamps. If one of the lamp goes dark and the other two burn normally before and after the test switch is operated, this indicates _______________. ... of the three phases D. the voltage to the dark lamp is less than that of the system

Last Answer : Answer: A

Description : In a three-phase electrical system, three ground detecting lamps are provided. If all three lamps REMAIN at half-brilliance when the ground detecting test switch is operated, ______________. A. there is a ... must be replaced C. there are no grounds present D. the light bulbs are of improper voltage

Last Answer : Answer: C

Description : In the event of a power failure during cargo loading operations, the movement of an electric powered cargo winch will be stopped by ____________. A. a manual override switch B. the weight of the load on the boom C. a spring set brake D. a hand operated band brake

Last Answer : Answer: C

Description : If a three-phase induction motor is operated under a light load and it develops an open in one of its supply lines, the motor will _____________. A. continue to run, but will vibrate and have reduced ... speed up due to the reduced number of poles C. run cooler due to reduced current flow D. stop

Last Answer : Answer: A

Description : Peripheral components for the operation of the astern valve position amplifier circuit shown in the illustration are _____________. EL-0099 A. resistors B. operated on +28 volts D.C. C. located on a separate circuit card D. all of the above

Last Answer : Answer: C

Description : The contacts operated by the D.C. relay coil shown in the illustration are located in the schematic diagram prints at coordinates ____________. EL-0100 A. '41Y' on this page B. '52M52M' and '52H35M' C. '57R' on this page D. '52N' on page '57R'

Last Answer : Answer: C

Description : The vertical dotted line connecting the small circular symbols at coordinates '05L', '09L', '13L', '21L', '25L', etc., shown in the illustration, indicate that all _______________. EL-0100 A. contacts are ... board 'TB2' C. wires are grounded at both ends of the line D. wires have a common shield

Last Answer : Answer: B

Description : A useful instrument for checking A.C. motor performance by measuring possible unbalanced currents is the _____________. A. hand or battery-operated megger B. vibrating-reed frequency meter C. hook-on voltmeter-ammeter D. D'Arsonval iron-vane probe

Last Answer : Answer: C

Description : The 'safe switch' of the winch controller shown in the illustration is operated _______________. EL-0102 A. through the master switch handle B. when heater circuit current is high C. by contactor coil 'FR' D. manually by the winch operator

Last Answer : Answer: D

Description : If an induction motor were to be operated at 90% rated voltage, _____________. A. there would be an increase in starting torque B. starting current would increase slightly C. synchronous speed would decrease slightly D. the slip would increase

Last Answer : Answer: D

Description : If the 'E/P converter' shown in the illustration operated on a range of 1-9 volts and 6-30 PSI, a 5 volt input would yield ______________. EL-0096 A. 9 PSI B. 15 PSI C. 18 PSI D. 24 PSI

Last Answer : Answer: C

Description : The simplest method of controlling the terminal voltage of compound-wound DC generator is with a _____________. A. hand-operated field rheostat connected in series with the shunt field circuit B. ... in series with the load D. balance coil diverting neutral current through the shunt field

Last Answer : Answer: A

Description : What will happen if Transformer is operated at 100 HZ Frequency?

Last Answer : 1. As per EMF equation of the transformer frequency is directly proportional to winding voltage. If we double the frequency the sinusoidal root mean winf=ding voltage also doubled. E=4.44 * f*b*n* ... core 5) This is followed by heating up of the oil and thus cooling temperature goes down sharply.

Description : Can 60 Hz transformers be operated at 50 Hz?

Last Answer : The transformers rated below 1 KVA can be used on 50 Hz service. Transformers 1 KVA and larger, rated at 60 Hz, should not be used on 50 Hz service, due to the higher losses and resultant heat ... designs are required for this service. However, any 50 Hz transformer will operate on a 60 Hz service.

Description : Can Transformers be Operated at Voltages other than Nameplate Voltages?

Last Answer : In some cases, transformers can be operated at voltages below the nameplate rated voltage. In NO case should a transformer be operated at a voltage in excess of its name- plate rating unless taps are ... 10 KVA, the reduced rating would be 5 KVA, or in direct proportion to the applied voltage.

Description : Why CT operated over load relay is using for loads of high acceleration time upto 30 seconds? How it getting back?

Last Answer : The saturable current transformers linearly transforms the current upto twice the set current, but above this value the transformer core gets saturated and the secondary current is proportionally less. Thus ... overload. When current reduces the core gets de-saturated, as material design is such. 

Description : What precaution should be taken while removing a current operated relay when the equipment is in service?

Last Answer : Ensure that the CT is not getting opened by shorting the appropriate terminals. (Eventhough the terminals are automatically shorted once relay is removed the above point may carried out to ensure the same) 

Description : An a.c. tachometer is just a ________with one phase excited from the carrier frequency. (A) two-phase A.C. servomotor (B) two-phase induction motor (C) A.C. operated universal motor (D) hybrid stepper motor.

Last Answer : Ans: D This is a special purpose machine whose stator coil can be energized by electronically switched current.

Description : The torque-speed characteristics of an a.c. operated universal motor has a ______characteristic and it______ be started under no-load condition. (A) inverse, can (B) nearly inverse, can (C) inverse, cannot (D) nearly inverse, cannot

Last Answer : Ans: C If torque is zero then speed may exceed up to infinite, that is dangerous for machine and machine can be damaged. N α 1/ T

Description : A motor which can conveniently be operated at lagging as well as leading power factors is the (A) squirrel cage induction motor. (B) wound rotor induction motor. (C) synchronous motor. (D) DC shunt motor.

Last Answer : (C) synchronous motor.

Description : Overfluxing protection is recommended for (a) distribution transformer (b) generator transformer of the power plant (c) auto-transformer of the power plant (d) station transformer of the power plant

Last Answer : (b) generator transformer of the power plant

Description : Autotransformer starters or compensators are sometimes used with polyphase induction motors to _____________. A. reduce the voltage applied to the motor during the starting period B. increase the voltage for ' ... to be either stepped up or down, depending on the application, to ensure full torque

Last Answer : Answer: A