The equipment frequently used for adiabatic humidification-cooling
operation with recirculating liquid is
(A) Natural draft cooling tower
(B) Induced draft cooling tower
(C) Spray chamber
(D) None of these

1 Answer

Answer :

(C) Spray chamber

Related questions

Description : When the temperature and humidity of air is low, we usually use __________ draft cooling tower. (A) Natural (B) Forced (C) Induced (D) None of these

Last Answer : (A) Natural

Description : The most efficient cooling tower out of the following is (A) Induced draft (B) Forced draft (C) Natural draft (D) Atmospheric

Last Answer : (A) Induced draft

Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Description : Flue gas from the heating chamber of byproduct coke ovens is removed by (A) Forced draft fan (B) Induced draft fan (C) Steam ejector (D) Natural draft

Last Answer : (D) Natural draft

Description : What Are The Advantages Of Induced Draft Cooling Tower Over Forced Draft Cooling Tower?

Last Answer : 1. The outlet water comes in contact with the driest air and warmest water comes in contact with most humid air. 2. The re-circulation is seldom a problem. 3. The first cost is low due to the reduction in pump power consumption.

Description : Explain the construction and working of induced draft cooling tower with neat sketch.

Last Answer : Induced draft cooling tower :  Diagram: Construction and working: Cooling towers are employed to cool utility cooling water by direct contact with air. The parts of a cooling tower are ... top pulls the hot air through the fills and cooled water gets collected in the cold water basin.

Description : Which of the following processes is followed by unsaturated air (with dry bulb temperature 12°C and relative humidity 47%) passing through water spray washer (temperature of water being constant at 40°C ... (B) Heating only (C) Both heating and humidification (D) Evaporative cooling

Last Answer : (C) Both heating and humidification

Description : Use of natural draft cooling tower is practised, when the air has low (A) Humidity (B) Temperature (C) Both 'a' & 'b' (D) Neither 'a' nor 'b'

Last Answer : (C) Both 'a' & 'b

Description : A natural draft cooling tower is filled with wooden grids, which covers about __________ percent of the tower height. (A) 10-15 (B) 30-40 (C) 70-80 (D) 90-100

Last Answer : (A) 10-15

Description : If the flame is produced under the hearth and then sweeps up into the heating chamber, this is called a/an __________ furnace. (A) Sidefired (B) Underfired (C) Covered (D) Recirculating

Last Answer : (B) Underfired

Description : Which among the following are the components of natural draft cooling tower a) Supply basin b) reinforced concrete c) Hot water distribution d) none of the above

Last Answer : reinforced concrete

Description : In the natural draft cooling tower_________ is not required a) Fan b) tower c) Nozzle d) none of the above

Last Answer : Fan

Description : In natural draft cooling tower the air flow is obtained by___________ a) Difference in air pressure b) difference in air temperature c) Difference in air speed d) none of the above

Last Answer : Difference in air pressure

Description : Natural draft cooling tower are mainly used in a) Steel Industry b) Alumina industry c) Fertilizer industry d) Power station

Last Answer : Power station

Description : Natural draft in hyperbolic cooling tower is used for production of a) Fertilizer b) Steel c) Chemical d) Electrical energy

Last Answer : d) Electrical energy

Description : Design of hyperbolic cooling tower standard for all cooling tower a) Mechanical draft b) Natural draft c) Both a & b d) Neither a & b

Last Answer : b) Natural draft

Description : In adiabatic evaporative cooling, heat transfer between chamber and surroundings is ____ A. zero B. high C. low D. none of the mentioned

Last Answer : ANSWER : A

Description : Pick out the wrong statement. (A) With decrease in feed temperature, the number of plates required for binary distillation decreases for a given L/V' ratio (B) The extraction per unit ... and its cross￾section is wider at the bottom (D) Vander wall adsorption is also called chemisorption

Last Answer : (D) Vander wall adsorption is also called chemisorption

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : Pick out the wrong statement. (A) Different solids have different equilibrium moisture curves (B) Total condenser or reboiler is considered equivalent to one theoretical plate in McCabe-Thiele method of ... (D) Even a forced draft cooling tower cannot cool water below the wet bulb temperature

Last Answer : (C) Heat removal load on cooler remains constant, even with increase of the reflux ratio in a distillation column

Description : Which of the following employs an accessory known as 'drift eliminator'? (A) Multiple effect evaporator (B) Mechanical draft cooling tower (C) Rotary dryer (D) Rotating disc contacto

Last Answer : (B) Mechanical draft cooling tower

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : Define Forced Draft And Induced Draft Cooling Towers?

Last Answer : If the fan is located at the bottom of the tower and air is blown by the fan up through the descending water it is called as forced draft cooling towers. If the fan is located at the top of the ... on the tower's side and drawn up and discharge through the fan casing, it is called as induced draft.

Description : Differentiate induced draft and forced draft cooling towers based on (i) Location of fan (ii) Corrosion of blades (iii) Efficiency (iv) Fan size

Last Answer : Differentiate induced draft and forced draft cooling towers based on (i) Location of fan (ii) Corrosion of blades (iii) Efficiency (iv) Fan size

Description : The equipment used in the extraction of highly corrosive radioactive liquids is (A) Pulse column (B) Spray column (C) Mixer settler (D) Baffle tower

Last Answer : (A) Pulse column

Description : Which of the following is the simplest method of cooling the condenser water? • Spray cooling pond • Cooling tower • Indirect air cooling • Hyperbolic cooling tower

Last Answer : Spray cooling pond

Description : Which of the following is the simplest method of cooling the condenser water? a. Spray cooling pond b. Cooling tower c. Indirect air cooling d. Hyperbolic air cooling

Last Answer : a. Spray cooling pond

Description : Which of the following is the simplest method of cooling the condenser water? A] Spray cooling pond B] Cooling tower C] Indirect air cooling D] Hyperbolic cooling tower

Last Answer : A] Spray cooling pond

Description : Evaporative cooling process employs a combination of cooling and humidification in which the (A) Sensible heat is added (B) Sensible heat is removed and the latent heat is added (C) Latent heat is removed (D) Sensible heat is added and latent heat is removed

Last Answer : Option B

Description : The ……….-induced response of cooling tower is the key factor to improve safety and to reduce tower crack. a) wind c) heat b) water d) steam

Last Answer : wind

Description : The horizontal line in psychrometric chart joining the change of state of air represents A. humidification B. sensible cooling or heating C. sensible cooling or heating with humidification D. sensible cooling or heating with dehumidification

Last Answer : ANSWER : B

Description : When, H1 = Total heat of air entering the coil (heating or cooling) H2 = Total heat of air leaving the coil (heating or cooling) H3 = Total heat of air at the end of ... A. cooling and humidification B. cooling and dehumidification C. heating and humidification D. heating and dehumidification

Last Answer : ANSWER : C

Description : Make up water is supplied during cooling tower operation to compensate for water losses due to (A) Evaporation (B) Blowdown (C) Entrainment (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : A packed tower compared to a plate tower for a particular mass transfer operation (A) Incurs smaller pressure drop (B) Allows installation of cooling coils (C) Is less costly when built in large sizes/diameters (D) Is more suitable, if suspended solids are present in fluid stream

Last Answer : (A) Incurs smaller pressure drop

Description : Which of the following is not categorised as a "mechanical operation”? (A) Agitation (B) Filtration (C) Size enlargement (D) Humidification

Last Answer : (D) Humidification

Description : Even though bubble cap towers are very effective for humidification operation, they are not used commonly in industries, because of the (A) High evaporation losses of water (B) High pressure drop of the gas (C) Difficulty in its fabrication (D) None of these

Last Answer : (B) High pressure drop of the gas

Description : Humidification involves mass transfer between a pure liquid phase and a fixed gas, which is (A) Insoluble in the liquid (B) Soluble in the liquid (C) Non-ideal in nature (D) At a fixed temperature

Last Answer : (A) Insoluble in the liquid

Description : Coke oven gas is a better fuel than blast furnace gas, because of its higher (A) Calorific value, cleanliness and relatively low distribution cost (due to its low specific gravity) (B) Adiabatic flame temperature ... release rate (thus requiring smaller combustion chamber) (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : A fuel with high heat release rate will (A) Require smaller combustion chamber (B) Have high calorific value (C) Have high adiabatic flame temperature (D) None of these

Last Answer : (A) Require smaller combustion chamber

Description : What Are The Advantages Of Hyperbolic Natural-draft Cooling Towers?

Last Answer :  Since no fans are used power cost and auxiliary equipments cost is reduced.  Hyperbolic tower chimney creates its own draft even when there is no wind.  Ground fogging and warm air re-circulation are avoided in hyperbolic towers.  The structure is more or less self-supported.

Description : . Improved cooling efficiency and minimum usage of material are the key features of ______ a. Natural draft cooling towers b. Cross flow towers c. Hyperbolic cooling d. All of above

Last Answer : Hyperbolic cooling

Description : . _____ type of cooling towers are used with nuclear power plants. a. Cross flow b. Natural draft c. Hyperbolic d. None of above

Last Answer : Hyperbolic

Description : Hyperbolic cooling towers are also referred as a. Natural draft towers b. Cross flow towers c. Hyperboloid towers d. None of the above

Last Answer : Hyperboloid towers

Description : Hyperbolic cooling towers have become design standard for all natural draft structural towers because usage of . a. Their structural strength b. Minimum usage of material. c. Improving cooling efficiency d. All of the above.

Last Answer : All of the above.

Description : Natural draft cooling towers are mainly used in the _____. • Steel industry • Fertilizer industry • Alumina industry • Power stations

Last Answer : Power stations

Description : __________ Cooling towers have become the design standard for all natural-draft cooling towers because oftheir structural strength and minimum usage of material. • HCT • CCT • Hyperboloid • None

Last Answer : Hyperboloid

Description : Natural draft in hyperbolic cooling towers reduces of fans a) Damage b) Efficiency c) Cost d) Speed

Last Answer : c) Cost

Description : Describe with neat sketch working of natural draft cooling towers.

Last Answer : Natural draft cooling tower: -In natural draught cooling tower, the circulation of air is produced by the pressure difference of air inside the tower and outside atmospheric air Hot cooling water falls down ... the pressure difference of air inside and outside of cooling tower (natural flow).

Description : Unsaturated air (with dry bulb and wet bulb temperatures being 45°C and 25°C respectively) is passed through a water spray chamber maintained at 23°C. The air will be cooled and (A) ... temperature decreasing B) Humidified at constant wet bulb temperature (C) Dehumidified (D) None of these

Last Answer : (A) Humidified with wet bulb temperature decreasing

Description : Unsaturated air (with dry bulb temperature and dew point being 35°C and 18°C respectively) is passed through a water spray chamber maintained at 15°C. The air will be cooled (A) And ... (C) At the same relative humidity (D) And dehumidified with decrease in wet bulb temperature

Last Answer : (D) And dehumidified with decrease in wet bulb temperature