The wetted wall tower is used to determine
(A) Individual mass transfer co-efficient (M.T.C.) in gaseous system
(B) M.T.C. of individual components in a liquid-liquid system
(C) M.T.C. of liquid in liquid-gas system
(D) The overall M.T.C. of the system

1 Answer

Answer :

(A) Individual mass transfer co-efficient (M.T.C.) in gaseous system

Related questions

Description : In a vapor-liquid contacting equipment, the overall gas phase mass transfer co-efficient (M.T.C), KG is related to individual co-efficients (KG and KL ) as (A) KG = 1/KG + m/KL (B) 1/KG = 1/KG + m/KL (C) 1/KG = 1/KL + m/KG (D) KG = 1/KL + m/KG

Last Answer : (B) 1/KG = 1/KG + m/KL

Description : Wetted wall tower experiment determines the (A) Molal diffusivity (B) Volumetric co-efficient (C) Mass transfer co-efficient (D) None of these

Last Answer : (C) Mass transfer co-efficient

Description : For experimental determination of mass transfer co-efficient by wetted wall tower, the mass transfer area is (A) Calculated (B) Unknown (C) Known (D) Not required

Last Answer : (C) Known

Description : Experimental determination of __________ is done by wetted wall column method. (A) Diffusion co-efficient (B) Mass transfer co-efficient (C) NTU (D) None of these

Last Answer : (B) Mass transfer co-efficient

Description : The overall mass transfer co-efficient for the absorption of SO2 in air with dilute NaOH solution can be increased substantially by (A) Increasing the gas film co-efficient (B) Increasing the liquid film co-efficient (C) Increasing the total pressure (D) Decreasing the total pressure

Last Answer : (A) Increasing the gas film co-efficient

Description : Out of the following gas-liquid contacting devices, for a given set of operating conditions, gas pressure drop is the least in __________ tower. (A) Wetted wall (B) Bubble cap (C) Perforated tray (D) Packed

Last Answer : (A) Wetted wall

Description : Which of the following gas-liquid contacting devices incurs the least pressure drop for a particular duty? (A) Grid tray tower (B) Perforated tray tower (C) Wetted wall tower (D) Bubble cap tower

Last Answer : (D) Bubble cap tower

Description : __________ column is the most suitable for achieving the best performance for mass transfer operations involving liquid with dispersed solids. (A) Wetted wall (B) Packed (C) Plate (D) Spray

Last Answer : C) Plate

Description : H2S is being absorbed in a gas absorber unit. The height of the transfer unit based on the overall mass transfer coefficient on the gas side is 0.4 m. The equilibrium data is given by, y = 1.5 x. The bulk concentration of H2S ... by, y = 5x + 0.001 is (A) 2.0 (B) 1.56 (C) 1.0

Last Answer : (A) 2.0

Description : Pick out the wrong statement. (A) The condensing film co-efficient is about 3 times lower for vertical condenser as compared to the equivalent horizontal condenser for identical situation ( ... in a heat exchanger is controlled by the value of the film co-efficient, which is higher

Last Answer : (D) Overall heat transfer co-efficient in a heat exchanger is controlled by the value of the film co-efficient, which is higher

Description : Double pipe heat exchangers are preferably useful, when (A) High viscosity liquid is to be cooled (B) Requirement of heat transfer area is low (C) Overall heat transfer co-efficient is very high (D) A corrosive liquid is to be heated

Last Answer : (B) Requirement of heat transfer area is low

Description : The Reynolds number of the liquid was increased 100 fold for a laminar falling film used for gas-liquid contacting. Assuming penetrating theory is applicable, the fold increase in the mass transfer co-efficient (Kc ) for the same system is. (A) 100 (B) 10 (C) 5 (D) 1

Last Answer : (B) 10

Description : Measurement of the interfacial area of mass transfer is achieved easily & accurately in case of a __________ column. (A) Spray (B) Packed (C) Bubble cap plate (D) Wetted wall

Last Answer : (D) Wetted wall

Description : Diffusion co-efficient generally depends upon the temperature, pressure & the nature of the components of the system. Its dimension is not the same as that of the (A) Mass transfer co-efficient (B) Thermal diffusivity (C) Kinematic viscosity (D) Volumetric diffusivity

Last Answer : (A) Mass transfer co-efficient

Description : For absorbing a sparingly soluble gas in a liquid (A) Gas side mass transfer co-efficient should be increased (B) Liquid side mass transfer co-efficient should be increased (C) Liquid side mass transfer co-efficient should be decreased (D) Mass transfer co-efficient must be kept constant

Last Answer : (B) Liquid side mass transfer co-efficient should be increased

Description : Pick out the wrong statement. (A) Mass transfer co-efficient does not account for gas-liquid diffusion (B) Diffusion co-efficient and mass transfer co-efficient are not same in any mass transfer operation

Last Answer : (A) Mass transfer co-efficient does not account for gas-liquid diffusion

Description : The individual mass transfer co-efficients (moles/m2s) for absorption of a solute from a gas mixture into a liquid solvent are, KL = 4.5 and KG = 1.5. The slope of the equilibrium line is 3. Which of ... A) Liquid side (B) Gas side (C) Interfacial (D) Both liquid and gas side

Last Answer : (B) Gas side

Description : Out of the following four assumptions used in the derivation of theequation for LMTD [LMTD = (∆t1 - ∆t2 )/ln(∆t1 /∆t2 )], which one is subject to the largest deviation in practice ? (A) Constant ... (B) Constant rate of fluid flow (C) Constant specific heat (D) No partial phase change in the system

Last Answer : (B) Constant rate of fluid flow

Description : . The inner wall of a furnace is at a temperature of 700°C. The composite wall is made of two substances, 10 and 20 cm thick with thermal conductivities of 0.05 and 0.1 W.m-1.°C-1 respectively. The ambient air is at 30°C ... from the outer surface in W.m-2 is (A) 165.4 (B) 167.5 (C) 172.5 (D) 175

Last Answer : (A) 165.4

Description : Pick out the wrong statement. (A) In the McCabe-Thiele diagram for binary distillation, vertical feed line represents saturated liquid feed and horizontal feed line represents saturated vapour feed (B) In ... layers over a flat plate are of equal thickness, if Schmidt number is equal to unity

Last Answer : (C) For Laminar flow over a plate of length L, the local mass transfer co￾efficient at a distance L from the leading edge is 1.5 × 10 -2m/s. Then the average mass transfer co-efficient for the plate is 2 × 10 -2m/s

Description : Mass transfer co-efficient of liquid is (A) Affected more by temperature than that for gases (B) Affected much less by temperature than that for gases

Last Answer : (A) Affected more by temperature than that for gases

Description : The mass transfer co-efficient for a solid sphere of radius 'a' dissolving in a large volume of quiescent liquid, in which ‘D’ is the diffusivity of solute, is (A) D/a (B) D/2a (C) Proportional to √D (D) Dependent on the Reynolds number

Last Answer : (D) Dependent on the Reynolds number

Description : Overall heat transfer co-efficient for cooling of hydrocarbons by water is about (A) 50 -100 Kcal/hr.m2 .°C (B) 50 -100 W/m2 .°K (C) 50 -100 BTU/hr. ft. 2°F (D) 1000 - 1500 BTU/hr. ft. 2°F

Last Answer : (C) 50 -100 BTU/hr. ft. 2°F

Description : In case of vertical tube evaporator, with increase in liquor level, the overall heat transfer co-efficient (A) Increases (B) Decreases (C) Is not affected (D) May increase or decrease; depends on the feed

Last Answer : (B) Decreases

Description : If h1 = inner film co-efficient and /h2 = outer film co-efficient, then the overall heat transfer co-efficient is (A) Always less than h1 (B) Always between h1 and h2 (C) Always higher than h2 (D) Dependent on metal resistance

Last Answer : (B) Always between h1 and h2

Description : Overall heat transfer co-efficient of a particular tube is U1 . If the same tube with some dirt deposited on either side has coefficient U2 , then (A) U1 = U2 (B) U2 > U1 (C) U1 > U2 (D) U1 = dirt factor - U2

Last Answer : (A) U1 = U2

Description : Which of the following has the lowest overall heat transfer co-efficient? (A) Dowtherm (B) Molten sodium (C) Water (D) Air

Last Answer : (D) Air

Description : The overall heat transfer co-efficient for a shell and tube heat exchangerfor clean surfaces is U0 = 400 W/m2 .K. The fouling factor after one year of operation is found to be hd0 = 2000 W/m2 .K. The overall heat transfer co￾efficient ... 1200 W/m2 .K (B) 894 W/m2 .K (C) 333 W/m2 .K (D) 287 W/m2 .K

Last Answer : (C) 333 W/m2 .K

Description : The relation among various mass transfer co-efficients (M.T.C) for ideal gases is given by (where, Kc & Km are M.T.C. for equimolar counter diffusion with concentration & mole fraction respectively as the driving ... (C) Kc = Kp . RT = Km . RT/p (D) None of these

Last Answer : (C) Kc = Kp . RT = Km . RT/p

Description : In a packed tower, the value of HETP equals HTUOG, when the equilibrium and the operating lines are (where, HETP = height equivalent to a theoretical plate HTUOG = overall gas phase height of a transfer unit). (A) Straight (B) Parallel (C) Both (A) & (B) (D) Neither (A) nor (B

Last Answer : (C) Both (A) & (B)

Description : Which of the following liquid-vapor contacting devices provides maximum contact surface area for a particular duty? (A) Sieve plate column (B) Bubble cap column (C) Randomly packed column (D) Wetted wall column

Last Answer : (D) Wetted wall column

Description : Which of the following equipments is not used for liquid dispersion? (A) Wetted wall towers (B) Packed towers (C) Venturi scrubbers (D) Agitated vessels

Last Answer : (D) Agitated vessels

Description : Which one of the following devices is not used for both the absorption as well as the liquid-liquid extraction processes? (A) Packed towers (B) Plate towers (C) Spray towers (D) Wetted wall columns

Last Answer : (D) Wetted wall columns

Description : Which of the following equipments is used for liquid dispersion? (A) Packed column (B) Venturi scrubber (C) Bubble cap plate column (D) Wetted wall column

Last Answer : Option B

Description : A first order gaseous phase reaction is catalysed by a non-porous solid. The kinetic rate constant and the external mass transfer co-efficients are k and kg respectively. The effective rate constant (ke ff) is given by (A) ke ff = k + kg ( ... + kg )/2 (C) ke ff = (kkg ) 1/2 (D) 1/ke ff = 1/k + 1/kg

Last Answer : (D) 1/ke ff = 1/k + 1/kg

Description : Pick out the wrong statement. (A) The Reynolds analogy for mass transfer is given by Lewis relation and is applicable, when Schmidt number is one (B) Sherwood number for flow in pipes can be expressed ... flux of a component A in binary mixture of A and B is given by - Dab'.dCA/dz

Last Answer : (C) According to film theory for equimolar counter diffusion, the mass transfer coefficient is given by DAB(B)P - 3, Q - 2

Description : As the difference between the wall temperature and bulk temperature increases, the boiling heat transfer co-efficient (A) Continues to increase (B) Continues to decrease (C) Goes through a minimum (D) Goes through a maximum

Last Answer : (C) Goes through a minimum

Description : Walls of a cubical oven are of thickness l, and they are made of material of thermal conductivity k. The temperature inside the oven is 100°C and the inside heat transfer co-efficient is 3k/l'. If the wall temperature ... wall temperature in degree centigrade? (A) 35.5 (B) 43.75 (C) 81.25 (D) 48.25

Last Answer : (C) 81.25

Description : __________ column is used in gas absorption process. (A) Wetted wall (B) Sieve/perforated tray (C) Bubble cap (D) Packed

Last Answer : (D) Packed

Description : Heat transfer rate to the charge/stock in a furnace does not depend upon the (A) Type of fuels viz. solid, liquid or gaseous (B) Flue gas temperature (C) Emissivity of refractory walls (D) Initial temperature of the charged stock

Last Answer : (A) Type of fuels viz. solid, liquid or gaseous

Description : Pick out the wrong statement. (A) The shear stress at the pipe (dia = D, length = L) wall in case of laminar flow of Newtonian fluids is (D/4L). ∆p (B) In the equation, T. gc = k. ... to motion (D) With increase in the Mach number >0.6, the drag co-efficient decreases in case of compressible fluids

Last Answer : (D) With increase in the Mach number >0.6, the drag co-efficient decreases in case of compressible fluids

Description : Gaseous diffusion co-efficient increases with increase in the (A) Pressure (B) Temperature (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (B) Temperature

Description : Baffles in the shell side of a shell and tube heat exchanger (A) Increase the cross-section of the shell side liquid (B) Force the liquid to flow parallel to the bank (C) Increase the shell side heat transfer co-efficient (D) Decrease the shell side heat transfer co-efficient

Last Answer : (C) Increase the shell side heat transfer co-efficient

Description : The inside heat transfer co-efficient in case of turbulent flow of liquid in the tube side in a 1-2 shell and tube heat exchanger is increased by __________ times, when the number of tube passes is increased to 8. (A) 2 0.8 (B) 4 0.8 (C) 4 0.4 (D) 2 0.4

Last Answer : (B) 4 0.8

Description : The main reason for dividing a tall packed tower into series of small towers is to (A) Minimise the overall pressure drop (B) Avoid flooding (C) Reduce liquid hold up (D) Avoid channelling

Last Answer : (D) Avoid channelling