Which one of the following devices is not used for both the absorption as

well as the liquid-liquid extraction processes?

(A) Packed towers

(B) Plate towers

(C) Spray towers

(D) Wetted wall columns

1 Answer

Answer :

(D) Wetted wall columns

Related questions

Description : __________ column is the most suitable for achieving the best performance for mass transfer operations involving liquid with dispersed solids. (A) Wetted wall (B) Packed (C) Plate (D) Spray

Last Answer : C) Plate

Description : Which of the following liquid-vapor contacting devices provides maximum contact surface area for a particular duty? (A) Sieve plate column (B) Bubble cap column (C) Randomly packed column (D) Wetted wall column

Last Answer : (D) Wetted wall column

Description : Measurement of the interfacial area of mass transfer is achieved easily & accurately in case of a __________ column. (A) Spray (B) Packed (C) Bubble cap plate (D) Wetted wall

Last Answer : (D) Wetted wall

Description : Which of the following equipments is not used for liquid dispersion? (A) Wetted wall towers (B) Packed towers (C) Venturi scrubbers (D) Agitated vessels

Last Answer : (D) Agitated vessels

Description : Which of the following equipments is used for liquid dispersion? (A) Packed column (B) Venturi scrubber (C) Bubble cap plate column (D) Wetted wall column

Last Answer : Option B

Description : Out of the following gas-liquid contacting devices, for a given set of operating conditions, gas pressure drop is the least in __________ tower. (A) Wetted wall (B) Bubble cap (C) Perforated tray (D) Packed

Last Answer : (A) Wetted wall

Description : Pick out the wrong statement. (A) With decrease in feed temperature, the number of plates required for binary distillation decreases for a given L/V' ratio (B) The extraction per unit ... and its cross￾section is wider at the bottom (D) Vander wall adsorption is also called chemisorption

Last Answer : (D) Vander wall adsorption is also called chemisorption

Description : Pick out the wrong statement. (A) Packed towers are preferred for vacuum operation, because the pressure drop through the packing is less and they (packings) also lessen the ... of liquid, problem of channelling, loading & flooding is generally encountered in packed towers

Last Answer : (C) Diameter of randomly packed tower is normally more than 1.2 metres

Description : __________ column is used in gas absorption process. (A) Wetted wall (B) Sieve/perforated tray (C) Bubble cap (D) Packed

Last Answer : (D) Packed

Description : Which of the following equipments is not used in liquid-liquid extraction? (A) Pachuka tank (B) Agitated vessels (C) Centrifugal extractors (D) Packed towers

Last Answer : (A) Pachuka tank

Description : __________ columns are used for liquid dispersion in a continuous gas phase. (A) Packed (B) Pulse (C) Bubble cap (D) Sieve plate

Last Answer : (A) Packed

Description : Pick out the correct statement. (A) For identical gas flow rates, less pressure drop occurs through a plate tower than through a packed tower (B) Plate column can handle greater liquid loads without flooding than packed ... duty, plate columns weigh less than packed columns (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Which of the following gas-liquid contacting devices incurs the least pressure drop for a particular duty? (A) Grid tray tower (B) Perforated tray tower (C) Wetted wall tower (D) Bubble cap tower

Last Answer : (D) Bubble cap tower

Description : Plate towers are preferred to packed towers, when large temperature changes are involved, because of the reason that the (A) Packing may be crushed due to thermal expansion/contraction of the ... C) Viscosity variation of the fluids may cause channelling/flooding (D) None of these

Last Answer : (A) Packing may be crushed due to thermal expansion/contraction of the components of the equipments

Description : The reason for preferring packed towers over plate towers in distillation practice is that the packed tower operation gives (A) Low pressure drop and high hold up (B) High pressure drop and low hold ... C) Low pressure drop and low hold up (D) High pressure drop and high hold up

Last Answer : (C) Low pressure drop and low hold up

Description : Which of the following same diameter columns gives lowest pressure drop per unit height? (A) Bubble-cap column (B) Sieve-plate column (C) Packed column (stacked)

Last Answer : (C) Packed column (stacked)

Description : Which of these columns incurs the lowest pressure drop? (A) Packed column (with stacked packing) (B) Packed column (with dumped packing) (C) Bubble plate column (D) Pulse column

Last Answer : (A) Packed column (with stacked packing)

Description : Extraction of penicillin employs a __________ extraction column. (A) Centrifugal (B) Packed (C) Plate (D) None of these

Last Answer : (A) Centrifugal

Description : Desulphurisation of petrol is done in a(A) Bollman extractor (B) Rotating disc extractor (C) Packed extraction column (D) Plate type extraction column

Last Answer : (B) Rotating disc extractor

Description : Perforated plate towers are unique for solvent extraction because, they provide (A) Higher contact area (B) Better contact of the phase (C) Repeated coalescence & redispersion of the drop phase (D) None of these

Last Answer : (C) Repeated coalescence & redispersion of the drop phase

Description : Very tall packed towers are divided into series of beds to (A) Reduce the overall pressure drop (B) Avoid channelling (C) Reduce liquid hold-up (D) Avoid flooding

Last Answer : (B) Avoid channelling

Description : The main reason for dividing a tall packed tower into series of small towers is to (A) Minimise the overall pressure drop (B) Avoid flooding (C) Reduce liquid hold up (D) Avoid channelling

Last Answer : (D) Avoid channelling

Description : The wetted wall tower is used to determine (A) Individual mass transfer co-efficient (M.T.C.) in gaseous system (B) M.T.C. of individual components in a liquid-liquid system (C) M.T.C. of liquid in liquid-gas system (D) The overall M.T.C. of the system

Last Answer : (A) Individual mass transfer co-efficient (M.T.C.) in gaseous system

Description : . __________ column is preferred to be used, when a high liquid hold up is required in a reactor for gas-liquid reaction. (A) Packed (B) Bubble (C) Spray (D) Tray

Last Answer : (B) Bubble

Description : When a high liquid hold up is required in a reactor for gas liquid reaction, use __________ column. (A) Packed (B) Spray (C) Tray (D) Bubble

Last Answer : (D) Bubble

Description : With increase in the liquid flow rate at a fixed gas velocity in a randomly packed counter current gas-liquid absorption column, the gas pressure drop (A) Decreases (B) Remains unchanged (C) Increases (D) Decreases exponentially

Last Answer : (C) Increases

Description : Channelling is most severe (A) In towers packed with stacked packing (B) In towers packed randomly with crushed solids (C) In dumped packing of regular units

Last Answer : (A) In towers packed with stacked packing

Description : Use of packed towers for distillation is generally limited to the (A) Small sizes (B) Multi-component distillation (C) High pressure operation (D) Vacuum distillation

Last Answer : (A) Small sizes

Description : Inside the distillation columns, the (A) Highest temperatures is near the feed plate (B) Driving force for the liquid flow is its weight (C) Vapors are not always at their dew points (D) All (A), (B) and (C)

Last Answer : (B) Driving force for the liquid flow is its weigh

Description : Pick out the wrong statement. (A) In the McCabe-Thiele diagram for binary distillation, vertical feed line represents saturated liquid feed and horizontal feed line represents saturated vapour feed (B) In ... layers over a flat plate are of equal thickness, if Schmidt number is equal to unity

Last Answer : (C) For Laminar flow over a plate of length L, the local mass transfer co￾efficient at a distance L from the leading edge is 1.5 × 10 -2m/s. Then the average mass transfer co-efficient for the plate is 2 × 10 -2m/s

Description : Which of the following unit operations makes use of Thiele-Geddes equation? (A) Liquid-liquid extraction (B) Solid-liquid extraction (C) Multi-component absorption with chemical reaction (D) Multi-component distillation

Last Answer : (D) Multi-component distillation

Description : Separation of two or more components of a liquid solution cannot beachieved by (A) Fractional crystallisation (B) Liquid extraction (C) Absorption (D) Evaporation

Last Answer : (C) Absorption

Description : Heat sensitive materials with very high latent heat of vaporisation may be economically separated using (A) Liquid extraction (B) Distillation (C) Evaporation (D) Absorption

Last Answer : (A) Liquid extraction

Description : Steady state equimolal counter diffusion occurs in case of (A) Leaching (B) Absorption (C) Binary phase distillation (D) Liquid-liquid extraction

Last Answer : (C) Binary phase distillation

Description : The recovery of penicillin from the acidified fermentation broth is done by (A) Distillation (B) Evaporation (C) Absorption (D) Liquid extraction

Last Answer : (D) Liquid extraction

Description : Tea percolation employs (A) Liquid-liquid extraction (B) Leaching (C) Absorption (D) None of these

Last Answer : (B) Leaching

Description : Wetted wall tower experiment determines the (A) Molal diffusivity (B) Volumetric co-efficient (C) Mass transfer co-efficient (D) None of these

Last Answer : (C) Mass transfer co-efficient

Description : For experimental determination of mass transfer co-efficient by wetted wall tower, the mass transfer area is (A) Calculated (B) Unknown (C) Known (D) Not required

Last Answer : (C) Known

Description : Laboratory determination of the diffusivity of vapor is done by __________ method. (A) Wetted wall column (B) Gilliland's (C) Winkelmann's (D) Wike's

Last Answer : (C) Winkelmann's

Description : Experimental determination of __________ is done by wetted wall column method. (A) Diffusion co-efficient (B) Mass transfer co-efficient (C) NTU (D) None of these

Last Answer : (B) Mass transfer co-efficient

Description : Which of the following equipments is not used for gas dispersion? (A) Agitated vessels (B) Bubble cap tray towers (C) Perforated sieve tray towers (D) Spray towers

Last Answer : (D) Spray towers

Description : In a packed absorption tower, if the equilibrium and operating lines are both straight lines, then the ratio, HETP/HTUOG __________ the absorption factor. (A) Increases with increase in (B) Is one at unity value of (C) Both (A) and (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) and (B)

Description : Which of the following is the most suitable for extraction in a system having very low density difference? (A) Mixer-settler extractor (B) Centrifugal extractor (C) Pulsed extractor (D) Packed extraction tower

Last Answer : (B) Centrifugal extractor

Description : In a packed tower, the value of HETP equals HTUOG, when the equilibrium and the operating lines are (where, HETP = height equivalent to a theoretical plate HTUOG = overall gas phase height of a transfer unit). (A) Straight (B) Parallel (C) Both (A) & (B) (D) Neither (A) nor (B

Last Answer : (C) Both (A) & (B)

Description : swirl plate in the cone nozzle is provided to. a. Impart rotational motion to the liquid passing through it. b. To increase the droplet size. c. To decrease the droplet size. d. To increase the spray angle.

Last Answer : a. Impart rotational motion to the liquid passing through it.

Description : In a moderately sized packed absorption tower, channelling (which is most severe with stacked packings) can be minimised by taking the ratio of tower diameter to packing diameter (A) > 4 :1 (B) < 8 : 1 (C) > 8:1 (D) < 6:1

Last Answer : (C) > 8:1

Description : In a packed bed absorption column, the channelling will be noted by the (A) Increase in flow rate (B) Sharp drop in pressure drop (C) Sharp rise in pressure drop (D) None of these

Last Answer : (B) Sharp drop in pressure drop

Description : Which of the following processes is followed by unsaturated air (with dry bulb temperature 12°C and relative humidity 47%) passing through water spray washer (temperature of water being constant at 40°C ... (B) Heating only (C) Both heating and humidification (D) Evaporative cooling

Last Answer : (C) Both heating and humidification

Description : . The most widely used crude topping column in refineries is the__________ column. (A) Bubble-cap (B) Packed bed (C) Fluidised bed (D) Perforated plate

Last Answer : (A) Bubble-cap