Out of the following gas-liquid contacting devices, for a given set of
operating conditions, gas pressure drop is the least in __________ tower.
(A) Wetted wall
(B) Bubble cap
(C) Perforated tray
(D) Packed

1 Answer

Answer :

(A) Wetted wall

Related questions

Description : Which of the following gas-liquid contacting devices incurs the least pressure drop for a particular duty? (A) Grid tray tower (B) Perforated tray tower (C) Wetted wall tower (D) Bubble cap tower

Last Answer : (D) Bubble cap tower

Description : __________ column is used in gas absorption process. (A) Wetted wall (B) Sieve/perforated tray (C) Bubble cap (D) Packed

Last Answer : (D) Packed

Description : Which of the following liquid-vapor contacting devices provides maximum contact surface area for a particular duty? (A) Sieve plate column (B) Bubble cap column (C) Randomly packed column (D) Wetted wall column

Last Answer : (D) Wetted wall column

Description : Which of the following equipments is used for liquid dispersion? (A) Packed column (B) Venturi scrubber (C) Bubble cap plate column (D) Wetted wall column

Last Answer : Option B

Description : Hydrogenation of oil is carried out in a/an __________ in Vanaspati manufacturing plant. (A) Agitated vessel (B) Sieve tray column (C) Bubble cap column (D) Packed tower

Last Answer : (A) Agitated vessel

Description : Measurement of the interfacial area of mass transfer is achieved easily & accurately in case of a __________ column. (A) Spray (B) Packed (C) Bubble cap plate (D) Wetted wall

Last Answer : (D) Wetted wall

Description : Which of the following equipments is not used for gas dispersion? (A) Agitated vessels (B) Bubble cap tray towers (C) Perforated sieve tray towers (D) Spray towers

Last Answer : (D) Spray towers

Description : . The most widely used crude topping column in refineries is the__________ column. (A) Bubble-cap (B) Packed bed (C) Fluidised bed (D) Perforated plate

Last Answer : (A) Bubble-cap

Description : Flooding in a vapor-liquid contacting equipment occurs in a tray, when the pressure drop through a tray is __________ the liquid head available in the downcomer. (A) Less than (B) More than (C) Same as (D) Very much less

Last Answer : (B) More than

Description : . __________ column is preferred to be used, when a high liquid hold up is required in a reactor for gas-liquid reaction. (A) Packed (B) Bubble (C) Spray (D) Tray

Last Answer : (B) Bubble

Description : When a high liquid hold up is required in a reactor for gas liquid reaction, use __________ column. (A) Packed (B) Spray (C) Tray (D) Bubble

Last Answer : (D) Bubble

Description : Small dia distillation column can be a (A) Packed column (B) Sieve tray (C) Bubble cap (D) Any of these

Last Answer : (A) Packed column

Description : Which one of the following devices is not used for both the absorption as well as the liquid-liquid extraction processes? (A) Packed towers (B) Plate towers (C) Spray towers (D) Wetted wall columns

Last Answer : (D) Wetted wall columns

Description : __________ columns are used for liquid dispersion in a continuous gas phase. (A) Packed (B) Pulse (C) Bubble cap (D) Sieve plate

Last Answer : (A) Packed

Description : Which of the following same diameter columns gives lowest pressure drop per unit height? (A) Bubble-cap column (B) Sieve-plate column (C) Packed column (stacked)

Last Answer : (C) Packed column (stacked)

Description : At the same gas flow rate, the pressure drop in a packed tower being irrigated with liquid __________ that in dry packed tower. (A) Is greater than (B) Is lower than (C) Is same as (D) Cannot be predicted as data are insufficient

Last Answer : (A) Is greater than

Description : Pick out the wrong statement. (A) Packed towers are preferred for vacuum operation, because the pressure drop through the packing is less and they (packings) also lessen the ... of liquid, problem of channelling, loading & flooding is generally encountered in packed towers

Last Answer : (C) Diameter of randomly packed tower is normally more than 1.2 metres

Description : __________ column is the most suitable for achieving the best performance for mass transfer operations involving liquid with dispersed solids. (A) Wetted wall (B) Packed (C) Plate (D) Spray

Last Answer : C) Plate

Description : Under conditions of flooding in packed tower, the gas pressure drop (A) Decreases rapidly (B) Increases rapidly (C) Remain constant (D) Is maximum

Last Answer : (D) Is maximum

Description : Pick out the correct statement. (A) For identical gas flow rates, less pressure drop occurs through a plate tower than through a packed tower (B) Plate column can handle greater liquid loads without flooding than packed ... duty, plate columns weigh less than packed columns (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : The wetted wall tower is used to determine (A) Individual mass transfer co-efficient (M.T.C.) in gaseous system (B) M.T.C. of individual components in a liquid-liquid system (C) M.T.C. of liquid in liquid-gas system (D) The overall M.T.C. of the system

Last Answer : (A) Individual mass transfer co-efficient (M.T.C.) in gaseous system

Description : Which of the following equipments is not used for liquid dispersion? (A) Wetted wall towers (B) Packed towers (C) Venturi scrubbers (D) Agitated vessels

Last Answer : (D) Agitated vessels

Description : Channelling in a packed tower results from the (A) High pressure drop (B) Maldistribution of liquid (C) Non-uniformity of packing (D) Both (B) and (C)

Last Answer : (D) Both (B) and (C)

Description : The main reason for dividing a tall packed tower into series of small towers is to (A) Minimise the overall pressure drop (B) Avoid flooding (C) Reduce liquid hold up (D) Avoid channelling

Last Answer : (D) Avoid channelling

Description : Even though bubble cap towers are very effective for humidification operation, they are not used commonly in industries, because of the (A) High evaporation losses of water (B) High pressure drop of the gas (C) Difficulty in its fabrication (D) None of these

Last Answer : (B) High pressure drop of the gas

Description : For contacting a highly soluble gas with a liquid (A) Bubble the gas through liquid (B) Spray the liquid on gas stream (C) Either (A) or (B) would suffice (D) None of these

Last Answer : (A) Bubble the gas through liquid

Description : Which of these columns incurs the lowest pressure drop? (A) Packed column (with stacked packing) (B) Packed column (with dumped packing) (C) Bubble plate column (D) Pulse column

Last Answer : (A) Packed column (with stacked packing)

Description : In an operating distillation column, the (A) Vapors and liquids are at their dew point and bubble point respectively (B) Driving force for the liquid flow is its specific weight (C) Driving force for ... bottom to the top of the column (D) Highest temperature is encountered at the top of the column

Last Answer : (C) Driving force for the vapor flow is the pressure drop, as the pressure decreases gradually from the bottom to the top of the column

Description : In distillation columns, the number of bubble caps per tray primarily depends upon the (A) Allowable liquid velocity (B) Allowable gas velocity (C) Allowable gas and liquid velocities

Last Answer : (C) Allowable gas and liquid velocities

Description : A packed tower compared to a plate tower for a particular mass transfer operation (A) Incurs smaller pressure drop (B) Allows installation of cooling coils (C) Is less costly when built in large sizes/diameters (D) Is more suitable, if suspended solids are present in fluid stream

Last Answer : (A) Incurs smaller pressure drop

Description : The reason for preferring packed towers over plate towers in distillation practice is that the packed tower operation gives (A) Low pressure drop and high hold up (B) High pressure drop and low hold ... C) Low pressure drop and low hold up (D) High pressure drop and high hold up

Last Answer : (C) Low pressure drop and low hold up

Description : Pressure drop through plate tower as compared to that through packed tower, for the same duty will be (A) Less (B) More (C) Equal (D) Either (A) or (B); depends on the packing height

Last Answer : (B) More

Description : Wetted wall tower experiment determines the (A) Molal diffusivity (B) Volumetric co-efficient (C) Mass transfer co-efficient (D) None of these

Last Answer : (C) Mass transfer co-efficient

Description : For experimental determination of mass transfer co-efficient by wetted wall tower, the mass transfer area is (A) Calculated (B) Unknown (C) Known (D) Not required

Last Answer : (C) Known

Description : In a packed absorption tower, if the equilibrium and operating lines are both straight lines, then the ratio, HETP/HTUOG __________ the absorption factor. (A) Increases with increase in (B) Is one at unity value of (C) Both (A) and (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) and (B)

Description : Operating velocity in a packed tower is usually __________ the flooding velocity. (A) Half (B) Twice (C) Equal to (D) More than

Last Answer : (A) Half

Description : Pick out the wrong statement: (A) Change in barometric pressure does not affect the relative humidity (B) In case of a packed tower, the operating velocity is about half of the ... (D) The equilibrium moisture content of the solid can be reduced by increasing the absolute humidity

Last Answer : (D) The equilibrium moisture content of the solid can be reduced by increasing the absolute humidity

Description : In a packed tower, the value of HETP equals HTUOG, when the equilibrium and the operating lines are (where, HETP = height equivalent to a theoretical plate HTUOG = overall gas phase height of a transfer unit). (A) Straight (B) Parallel (C) Both (A) & (B) (D) Neither (A) nor (B

Last Answer : (C) Both (A) & (B)

Description : With increase in the liquid flow rate at a fixed gas velocity in a randomly packed counter current gas-liquid absorption column, the gas pressure drop (A) Decreases (B) Remains unchanged (C) Increases (D) Decreases exponentially

Last Answer : (C) Increases

Description : Pressure drop in a packed bed for laminar flow is given by the __________ equation. (A) Kozeny-Carman (B) Blake-Plummer (C) Leva's (D) Fanning friction factor

Last Answer : (A) Kozeny-Carman

Description : Pressure drop in packed bed for turbulent flow is given by the __________ equation. (A) Kozeny-Carman (B) Blake-Plummer (C) Leva's (D) Hagen-Poiseuille’s

Last Answer : (B) Blake-Plummer

Description : Back-trapping in a distillation column (A) Increases tray efficiency (B) Decreases tray efficiency (C) Reduces pressure drop (D) Is desirable, as it provides improved vapour-liquid contact

Last Answer : (B) Decreases tray efficiency

Description : Very tall packed towers are divided into series of beds to (A) Reduce the overall pressure drop (B) Avoid channelling (C) Reduce liquid hold-up (D) Avoid flooding

Last Answer : (B) Avoid channelling

Description : Tower diameter may be decreased by (A) Using higher reflux ratio (B) Use of increased tray spacing (C) Increasing the liquid flow rate (D) Increasing the vapour flow rate

Last Answer : (B) Use of increased tray spacing

Description : For a fluid flowing in an annulus space, the wetted perimeter for heat transfer and pressure drop are (A) Same (B) Different (C) Never different (D) Linearly related

Last Answer : (B) Different

Description : Pressure drop in a fluidised bed reactor is __________ that in a similar packed bed reactor. (A) Less than (B) Greater than (C) Same as (D) None of these

Last Answer : (B) Greater than

Description : Pick out the wrong statement. (A) With decrease in feed temperature, the number of plates required for binary distillation decreases for a given L/V' ratio (B) The extraction per unit ... and its cross￾section is wider at the bottom (D) Vander wall adsorption is also called chemisorption

Last Answer : (D) Vander wall adsorption is also called chemisorption

Description : __________ is the temperature at which a gas-vapor mixture becomes saturated, when cooled at constant total pressure out of contact with a liquid. (A) Dew point (B) Bubble point (C) Dry bulb temperature (D) Wet bulb temperature

Last Answer : (A) Dew point

Description : A gas (density = 1.5 kg/m3 , viscosity = 2 10 -5 kg/m.s) flowing through a packed bed (particle size = 0.5 cm, porosity = 0.5) at a superficial velocity of 2 m/s causes a pressure drop of 8400 Pa/m. The ... flowing at 3 m/s will be (A) 8400 Pa/m (B) 12600 Pa/m (C) 18900 Pa/m (D) 16800 Pa/m

Last Answer : (B) 12600 Pa/m