If on­site slump test fails, should engineers allow the contractor to continue the
concreting works?

1 Answer

Answer :

This is a very classical question raised by many graduate engineers. In fact, there are two schools of thought regarding this issue.

The first school of thought is rather straightforward: the contractor fails to comply with contractual requirements and therefore as per G. C. C. Clause 54 (2)(c) the engineer could order suspension of the Works. Under the conditions of G. C. C. Clause 54(2)(a) – (d), the contractor   is   not   entitled   to   any   claims   of   cost   which   is   the   main   concern   for   most engineers. This is the contractual power given to the Engineer in case of any failure in tests required by the contract, even though some engineers argue that slump tests are not as important as other tests like compression test.

The second school of thought is to let the contractor to continue their concreting works and later   on   request   the   contractor   to   prove   that   the   finished   works   comply   with   other contractual   requirements   e.g.   compression   test.   This   is   based   upon   the   belief   that workability is mainly required to achieve design concrete compression strength. In case the compression   test  also   fails,  the   contractor  should  demolish  and  reconstruct  the  works accordingly. In fact, this is a rather passive way of treating construction works and is not recommended because of the following reasons:

(i) Workability of freshly placed concrete is related not only to strength but also to durability of concrete. Even if the future compression test passes, failing in slump test indicates that it may have adverse impact to durability of completed concrete structures.
(ii) In case the compression test fails, the contractor has to deploy extra time and resources to remove the work and reconstruct them once again and this slows down the progress of works significantly. Hence, in view of such likely probability of occurrence, why shouldn’t the Engineer exercise his power to stop the contractor and save these extra time and cost?

Related questions

Description : If a contractor proposes to increase concrete cover beyond contractual specification (i.e. 40mm to 70mm), shall engineers accept the proposal?

Last Answer : In contractual aspect, based on the requirement of General Specification of Civil Engineering Works (1992 Edition), the tolerance of concrete cover is between + ... larger cover. Therefore, with an increase of concrete cover, the crack width will increase which is undesirable.

Description : What are the major problems in using pumping for concreting works?

Last Answer : In pumping operation, the force exerted by pumps must overcome the friction between concrete and the pumping pipes, the weight of concrete and the pressure head when placing concrete above the ... other hand, a proper selection of aggregate grading helps to improve the pumpability of concrete.

Description : If concrete compression test fails, should Schmidt hammer test be adopted as an alternative test to prove the concrete strength?

Last Answer : The Scmidt hammer test is based on the elastic rebound of hammer which presses on concrete surface and it measures the surface hardness of concrete. Since the test is very sensitive to the ... strength of concrete. Therefore, it may not be considered a good substitute for concrete compression test.

Description : What is the indication of shear slump and collapse slump in slump tests?

Last Answer : There are three types of slump that may occur in slumps test, namely, true slump, shear slump and collapse slump. True slump refers to general drop of the concrete mass ... concrete. Collapse slump indicates that concrete mix is too wet ad the mix is deemed to be harsh and lean.

Description : In carrying out compression test for concrete, should test cubes or test cylinders be adopted?

Last Answer : Basically, the results of compression test carried out by using cubes are higher than that by cylinders. In compression test, the failure mode is in the form of tensile splitting induced by uniaxial ... are lower than that of cubes. Reference is made to Longman Scientific and Technical (1987).

Description : In concrete compression test, normally 150mmx150mmx150mm concrete cube samples is used for testing. Why isn’t 100mmx100mmx100mm concrete cube samples used in the test instead of 150mmx150mmx150mm concrete cube samples?

Last Answer : Basically, the force supplied by a concrete compression machine is a definite value. For normal concrete strength application, say below 50MPa, the stress produced by a ... cube size of 150mmx150mmx150mm is already sufficient for the crushing strength of the machine.

Description : Can grout replace concrete in normal structure?

Last Answer : The mixture of cement and water alone cannot replace concrete (Longman Scientific and Technical (1987)) because: (i) Shrinkage of grout is several times that of concrete with the same mass. (ii) ... of cement with water is more than normal concrete and this leads to the problem of severe cracking.

Description : What is the function of rebate in a typical construction joint?

Last Answer : Construction joints are created on sites to facilitate the construction process. However, if improperly constructed, the completed construction joints will leave an uneven scar on the concrete surface and affect ... After the other pour is concreted, it will hide the uneven joint inside the rebate.

Description : In erection of falsework, for a rectangular panel inside a falsework should it be braced along the two diagonals?

Last Answer : When a rectangular panel is subject to an eccentric load or a lateral load, it tends to deform into a parallelogram with one diagonal shortening and the other elongating. Theoretically, it is sufficient to ... may come from both sides of the panel and hence it should be braced in both diagonals.

Description : What are the disadvantages of curing by ponding and polythene sheets?

Last Answer : The purpose of curing is to reduce the rate of heat loss of freshly placed concrete to the atmosphere and to minimize the temperature gradient across concrete cross ... would be affected. Moreover, for water lost due to self­desiccation, this method cannot replenish these losses.

Description : Is it desirable to use concrete of very high strength i.e. exceeding 60MPa? What are the potential problems associated with such high strength concrete?

Last Answer : To increase the strength of concrete, say from 40MPa to 80MPa, it definitely helps in improving the structural performance of the structure by producing a denser, more durable and higher load ... Moreover, owing to a low aggregate content of high strength concrete, creep and shrinkage increases.

Description : In designing concrete structures, normally maximum aggregate sizes are adopted with ranges from 10mm to 20mm. Does an increase of maximum aggregate size benefit the structures?

Last Answer : To answer this question, let's consider an example of a cube. The surface area to volume ratio of a cube is 6/b where b is the length of the cube. This implies that ... requirement can offset the disadvantages brought about by discontinuities as suggested by Longman Scientific and Technical (1987).

Description : What is the function of shear keys in the design of retaining walls?

Last Answer : In determining the external stability of retaining walls, failure modes like bearing failure, sliding and overturning are normally considered in design. In considering the criterion of sliding, the sliding ... instead of 0.8φ in the previous case and the sliding resistance can be enhanced.

Description : What are the functions of different components of a typical expansion joint?

Last Answer : In a typical expansion joint, it normally contains the following components: joint sealant, joint filler, dowel bar, PVC dowel sleeve, bond breaker tape and cradle bent. Joint sealant: it seals the ... the joint . Cradle bar: It helps to uphold the dowel bar in position during construction.

Description : Why Should Pumping Be Not Used In Case Of Concreting Works?

Last Answer : Answer : During the pumping operation the pump exerted pressure must overcome any friction between the pumping pipes and the concrete, also the weight of the concrete and the pressure headwhen the ... Also if a proper selection of the aggregate grading can vastly improve the concrete pump ability.

Description : Suggest the type of cement used for the following : (i) For modular construction where form work needs to be removed early for re-use. . (ii) Mass concreting such as construction of dam. (iii) Decorative works in external surfaces of building. (iv) Cementing the oil well.

Last Answer : i) For modular construction where form work needs to be removed early for reuse. – Rapid Hardening Cement ii) Mass concreting such as construction of dam. – Low heat cement. iii) Decorative works in external surfaces of building – Coloured cement. iv) Cementing the oil well. – Oil Well Cement. 

Description : Knowledge of hydrology is necessary for civil engineers for (A) Designing and construction of irrigation structures (B) Designing and construction of bridges and culverts (C) Flood control works (D) All the above

Last Answer : Answer: Option D

Description : Slump test of concrete is a measure of its (A) Consistency (B) Compressive strength (C) Tensile strength (D) Impact value

Last Answer : (A) Consistency

Description : Slump test of concrete is a measure of its (A) Consistency (B) Compressive strength (C) Tensile strength (D) Impact value

Last Answer : (A) Consistency

Description : Slump test is done for (A) Clay (B) Sand (C) Lime (D) Concrete

Last Answer : Answer: Option D

Description : Workability of concrete is measured by (A) Vicat apparatus test (B) Slump test (C) Minimum void method (D) Talbot Richa

Last Answer : Answer: Option B

Description : Workability of concrete mix with low water cement ratio is determined by (A) Tensile strength test (B) Slump test (C) Compaction factor test (D) Flexural strength test

Last Answer : Answer: Option C

Description : In slump test, each layer of concrete is compacted by a steel rod 60 cm long and of 16 mm diameter for (A) 20 times (B) 25 times (C) 30 times (D) 50 time

Last Answer : Answer: Option B

Description : Slump test for concrete is carried out, to determine (A) Strength (B) Durability (C) Workability (D) Water content

Last Answer : Answer: Option C

Description : Pick up the correct statement from the following: (A) Plain cement concrete is equally strong in compression as well as in tension (B) Slump test is performed to check concrete strength (C ... D) Fineness modulus is the index number expressing the relative sizes of both coarse and fine aggregates

Last Answer : Option D

Description : The slump test of concrete is used to measure its (a) Consistency (b) Mobility (c) Homogeneity (d) All the above

Last Answer : (a) Consistency

Description : The top diameter, bottom diameter and height of the mould used for slump test are (a) 100mm, 200mm, 300mm (b) 200mm,100mm,300mm (c) 200mm,300mm,100mm (d) 100mm,300mm,200mm

Last Answer : (a) 100mm, 200mm, 300mm

Description : The steel mould used for slump test is in the form of a (a) Cube (b) Cylinder (c) Frustrum of a cone (d) None of these

Last Answer : (c) Frustrum of a cone

Description : Workability of a concrete – mix is determined by (i)Slump cone test (ii)Compaction factor test (iii)Vee bee test [ A ] i [ B ] ii [ C ] i and ii [ D ] i, ii and iii

Last Answer : [ D ] i, ii and iii

Description : Slump test of concrete is a measure of its [ A ] Consistency [ B ] Compressive strength [ C ] Tensile strength [ D ] Impact value

Last Answer : [ A ] Consistency

Description : Workability of concrete mix with low water cement ratio is determined by [ A ] Tensile strength test [ B ] Slump cone test [ C ] Compaction factor test [ D ] Flexural strength test

Last Answer : [ C ] Compaction factor test

Description : While determining the workability of concrete mix, the compaction factor test is ------than the slump cone test [ A ] Less accurate [ B ] More accurate [ C ] Approximate method [ D ] None of the above

Last Answer : [ B ] More accurate

Description : Slump cone test is used to determine [ A ] Shrinkage of concrete mix [ B ] Creep of concrete [ C ] Workability of concrete mix [ D ] Soundness of concrete

Last Answer : [ C ] Workability of concrete mix

Description : In case of laying gullies, siphons, intercepting traps, the cost includes (A) Setting and laying (B) Bed concreting (C) Connection to drains (D) All of these

Last Answer : (D) All of these

Description : Consider the following activities in a building construction: 1. Concreting of roof slabs 2. Brick-jelly lime concrete terracing 3. Erection of form work for slab 4. Construction of parapet wall in terrace The correct sequence of these ... (B) 3, 1, 4, 2 (C) 3, 1, 2, 4 (D) 1, 3, 4, 2

Last Answer : (C) 3, 1, 2, 4

Description : For concreting tunnel linings, transportation of concrete is done by (A) Pans (B) Wheel borrows (C) Containers (D) Pumps

Last Answer : (D) Pumps

Description : For concreting of heavily reinforced sections without vibration, the workability of concrete expressed as compacting factor should be (A) 0.75 - 0.80 (B) 0.80 - 0.85 (C) 0.85 - 0.92 (D) Above 0.92

Last Answer : Answer: Option D

Description : For cold weathering concreting the cement used is (a) O.P.C (b) R.H.C (c) L.H.C (d) None of these

Last Answer : (b) R.H.C

Description : With reference to agriculture, what are Smother Crops ? a Crops that are grown for grazing of harvesting for immediate or future feeding of livestock. b Crops grown to conserve the soil ... season when main crop fails. e Crops whose culture practices allow the infestation of weeds intensively.

Last Answer : e Crops whose culture practices allow the infestation of weeds intensively.

Description : Pick up the correct statement from the following: (A) An unconfined compression test is a special case of triaxial compression test (B) An unconfined compression test is a special case of direct ... subjected to major principal stress till it fails due to shearing along the plane of the failure

Last Answer : Option A

Description : What Are The Different Type Of Slump Test Indications?

Last Answer : Answer : Slump tests are performed to empirically measure the work ability of fresh concrete. It is used to measure the consistency of the concrete. In general there are three different types of slumps that ... the mix of concrete is simply too wet. The mix is considered to be harsh and lean.

Description : Explain the procedure for measurement of workability of fresh concrete using slump cone test.

Last Answer : Test Procedure: i. Clean the mould from inside and apply oil to it. ii. Place the mould on smooth horizontal, rigid & non-absorbent surface or the centre of metallic tray. iii. Fill the mould ... top of cone. vi. Based on measured slump, the degree of workability is designated as follows.

Description : To indicate proper control of consistency of a freshly mixed concrete for pavement construction, the slump should be between (A) 3 to 5 cm (B) 4 to 6 cm (C) 5 to 7 cm (D) 7 to 10 cm

Last Answer : Answer: Option D

Description : The top diameter, bottom diameter and the height of a slump mould are: (A) 10 cm, 20 cm, 30 cm (B) 10 cm, 30 cm, 20 cm (C) 20 cm, 10 cm, 30 cm (D) 20 cm, 30 cm, 10 cm

Last Answer : (A) 10 cm, 20 cm, 30 cm

Description : If the slump of a concrete mix is 60 mm, its workability is (A) Very low (B) Low (C) Medium (D) High

Last Answer : Answer: Option C

Description : While compacting the concrete by a mechanical vibrator, the slump should not exceed (A) 2.5 cm (B) 5.0 cm (C) 7.5 cm (D) 10 cm

Last Answer : Answer: Option B

Description : Pick up the correct statement from the following: (A) Higher workability indicates unexpected increase in the moisture content (B) Higher workability indicates deficiency of sand (C) If the concrete mix is dry, the slump is zero (D) All the above

Last Answer : Answer: Option D

Description : Pick up the incorrect statement from the following: (A) The bottom and top ends of slump mould are parallel to each other (B) The axis of the mould is perpendicular to the end faces (C) The ... clean and free from set cement (D) The mould is in the form of a frustum of hexagonal pyramid

Last Answer : Answer: Option D

Description : Pick up the correct statement from the following: (A) An increase in water content must be accompanied by an increase in cement content (B) Angular and rough aggregates reduce the workability of the ... The slump of the concrete mix decreases due to an increase in temperature (D) All the above

Last Answer : Answer: Option D