What is the effect on speed if the load is increased on a 3 phase synchronous motor?

1 Answer

Answer :

The speed of operation remains constant from no load to maximum load in the motor operating at constant frequency bus bars.

Related questions

Description : What could be the reasons if a 3-phase synchronous motor fails to start?

Last Answer : It is usually due to the following reasons a. Voltage may be too low. b. Too much starting load. c. Open circuit in one phase or short circuit. d. Field excitation may be excessive

Description : Why a synchronous motor is a constant speed motor?

Last Answer : When load increase in synchronous motor the load angle δ also increases but speed remains constant. The further increase in load cause further increase in load angle. When load angle reaches ... out of synchronism. Hence the motor rotates at synchronous speed otherwise it comes out of synchronism.

Description : Hunting of a synchronous motor:

Last Answer : When the mechanical load is constant, the rotor settles down to an absolutely constant speed with the torque angle fixed by the particular delivered power. When there is a change in load the rotor speed ... are short circuited; copper bars are embedded in the faces of the field poles of the motor.

Description : A synchronous motor starts as usual but fails to develop its full torque. What could it be due to?

Last Answer : a. Exciter voltage may be too low. b. Field spool may be reversed c. There may be either open-circuit or short-circuit in the field.

Description : In what way synchronous motor is different from other motors?

Last Answer : All dc and ac motors work on the same principle. Synchronous motor operates due to magnetic locking taking place between stator and rotor magnetic fields.

Description : State the characteristic features of synchronous motor.

Last Answer : a. the motor is not inherently self starting b. The speed of operation is always in synchronous with the supply frequency irrespective of load conditions c. The motor is capable of operating at any power factor.

Description : Write the applications of synchronous motor.

Last Answer : a. Used for power factor improvement in sub-stations and in industries. b. As synchronous condenser c. Used for constant speed applications

Description : What are V and inverted V curves of synchronous motor ?

Last Answer : The variation of magnitude of line current with respect to the field current is called V curve . The variation of power factor with respect to the field current is called inverted V curve.

Description : How the synchronous motor can be used as s synchronous condenser?

Last Answer : Synchronous motor is operated on over excitation so as to draw leading reactive current and power from the supply lines. This compensates the lagging current and power requirement of the load making ... to become unity. The motor does the job of capacitors and hence called as synchronous condenser.

Description : Why damper windings are used in synchronous motor? Or How synchronous motor is started as squirrel cage motor?

Last Answer : The damper winding consists of short circuited copper bars embedded in the the face of the rotor poles. When an ac supply is provided to stator of a 3-phase synchronous motor, stator winding produces ... magnetic field and damper winding is zero. Hence there will be no emf induced in damper winding.

Description : What are the methods of starting synchronous motor?

Last Answer : 1. Pony motor starting( using ac or dc motor) 2. Starting as squirrel cage Induction motor or using damper winding 3. Starting as slip ring Induction motor or synchronous motor 4. Using dc machine coupled to it.

Description : Why synchronous motor is not self starting?

Last Answer : Synchronous motor is a doubly excited machine i.e two electrical inputs are provided to it. It's stator winding which consists of a 3 phase winding is provided with 3 phase supply and rotor ... due to attractive or repulsive force and remain in standstill condition. Hence it is not self starting.

Description : Distinguish between synchronous phase modifier and synchronous condenser

Last Answer : A synchronous motor used to change the power factor or power factor in the supply lines is called synchronous phase modifier. A synchronous motor operated at no load with over excitation condition to draw large leading reactive current and power is called a synchronous condenser.

Description : What is synchronous condenser?

Last Answer : An over-excited synchronous motor under no load , used for the improvement of power factor is called as synchronous condenser because, like a capacitor it takes a leading current.

Description : What is pony motor starting?

Last Answer : In this method the rotor is made to rotate by some external device called pony motors. Once the rotor attains synchronous speed, the DC excitation to the rotor is switched on. Once synchronism is established the pony motor is decoupled. The synchronous motor continuously runs at synchronous speed.

Description : What is critical excitation?

Last Answer : The excitation for which power factor of the synchronous motor is unity and the back emf is equal to supply voltage.

Description : What is over excitation?

Last Answer : The excitation for which power factor of the synchronous motor is leading and the back emf is greater than supply voltage.

Description : What is under excitation?

Last Answer : The excitation for which power factor of the synchronous motor is lagging and the back emf is less than supply voltage.

Description : What is normal excitation?

Last Answer : The excitation for which power factor of the synchronous motor is lagging and the back emf is equal to supply voltage.

Description : What is pull out torque?

Last Answer : The maximum torque developed by the motor without pulling out of synchronism is called pull out torque. Its value varies from 1.5 to 3.5 times full load torque.

Description : What is pull in torque?

Last Answer : The torque which is required to pull the motor into synchronism when it is running as induction motor is called pull in torque.

Description : What are the effects of hunting?

Last Answer : Loses synchronism Develops mechanical stress on rotor shaft Increase machine losses Increase temperature of machine

Description : What is hunting?

Last Answer : The sudden changes of load on synchronous motor set up oscillations in the rotor. Such oscillation of rotor about its new equilibrium position is called hunting.

Description : What is the function of damper winding?

Last Answer : To provide starting torque To prevent or minimize hunting

Description : A synchronous motor is operating on no-load at unity power factor. If the field current is increased, power factor will become (A) Leading & current will decrease (B) Lagging & current will increase. (C) Lagging & current will decrease. (D) Leading & current will increase.

Last Answer : Ans: A Initially synchronous motor is operating at no load and unity power factor. When field current increases, the excitation will increase. Therefore, p.f will be leading and current will be I CosΦ < I

Last Answer : In case of a reluctance motor, when the load is increased so that it cannot maintain synchronous speed the motor will run as induction motor.

Description : A four-pole 60-hertz induction motor has a synchronous speed of 1800 RPM and a slip of 4 percent at full load. What will be its full load speed? A. 1728.0 RPM B. 1730.7 RPM C. 1800.0 RPM D. 1872.0 RPM

Last Answer : Answer: A

Description : The speed of a wound-rotor induction motor _____________. A. will be fixed by the number of field poles B. can be varied by a rheostat-type control C. can only be synchronous speed at full load D. can only attain synchronous speed at no load

Last Answer : Answer: B

Description : A salient pole synchronous motor is running at no load. Its field current is switched off. The motor will (A) come to stop. (B) continue to run at synchronous speed. (C) continue to run at ... more than the synchronous speed. (D) continue to run at a speed slightly less than the synchronous speed.

Last Answer : (B) continue to run at synchronous speed.

Description : A single phase Hysteresis motor (A) can run at synchronous speed only (B) can run at sub synchronous speed only (C) can run at synchronous and super synchronous speed (D) can run at synchronous and sub synchronous speed

Last Answer : Ans: A The rotor revolves synchronously because the rotor poles magnetically lock up with the revolving stator poles of opposite polarity

Description : The synchronous speed for a 3 phase 6-pole induction motor is 1200 rpm. If the number of poles is now reduced to 4 with the frequency remaining constant, the rotor speed with a slip of 5% will be _________. (A) 1690 rpm (B) 1750 rpm (C) 1500 rpm (D) 1710 rpm

Last Answer : (D) 1710 rpm

Description : The speed-torque characteristics of a DC series motor are approximately similar to those of the _________motor. (A) universal (B) synchronous (C) DC shunt (D) two-phase

Last Answer : Ans: A Universal motor has same characteristics as DC series motor and also known as an a.c series motor.

Description : In a 3-phase synchronous motor (A) the speed of stator MMF is always more than that of rotor MMF. (B) the speed of stator MMF is always less than that of rotor MMF. (C) the speed of ... speed while that of rotor MMF is zero. (D) rotor and stator MMF are stationary with respect to each other.

Last Answer : Ans: D Because, Motor is magnetically locked into position with stator, the rotor poles are engaged with stator poles and both run synchronously in same direction Therefore, rotor & stator mmf are stationary w.r.t each other.

Description : The effect of carrying field excitation excessively high on a synchronous motor will result in a _____________. A. tendency for the motor to fall out of step B. tendency for the motor to overspeed C. tendency for the motor to overheat D. loss of motor speed regulation

Last Answer : Answer: C

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Description : What is the effect of increased load on power factor of induction motor?

Last Answer : Power factor of an induction motor increases with loading.

Description : A three phase, salient pole synchronous motor is connected to an infinite bus. It is operated at no load a normal excitation. The field excitation of the motor is first reduced to zero ... First increases and then decreases steeply (C) First decreases and then increases steeply (D) Remains constant

Last Answer : B

Description : A three-phase synchronous motor connected to ac mains is running at full load and unity power factor. lf its shaft load is reduced by half and field current is held constant then its new power factor will be

Last Answer : Leading

Description : A 3~phase synchronous motor, connected to infinite bus, is operating at no load at normal excitation. The field excitation of the motor is first decreased to zero and then increased in the ... 2) First decrease and then increase, (3) Increases continuously (4) First increase and then decreased

Last Answer : A 3~phase synchronous motor, connected to infinite bus, is operating at no load at normal excitation. The field excitation of the motor is first decreased to zero and then increased in the reverse direction. The armature current of the synchronous motor will: Increases continuously.

Description : Which of the listed motors will operate at the highest RPM, assuming that each operates at the same frequency? A. A four-pole synchronous motor under normal load. B. A four-pole induction motor under ... A six-pole synchronous motor under normal load. D. A six-pole induction motor under full load.

Last Answer : Answer: A

Description : A four pole, 60 Hz, three-phase synchronous motor comes up to 1760 RPM when started as an induction motor. What is the percent slip after the rotor field is energized? A. 0 B. 1.1 C. 2.2 D. 3.3

Last Answer : Answer: A

Description : The direction of propeller shaft rotation in a turbo-electric synchronous propulsion drive motor is changed by reversing the _____________. A. polarity of the propulsion motor B. polarity of the propulsion generator C. phase sequence of power to the motor D. phase sequence of power to the generator

Last Answer : Answer: C

Description : A shaded-pole motor is a ____________. A. synchronous motor B. three-phase induction motor C. compound-wound motor D. single-phase induction motor

Last Answer : Answer: D

Description : A 3 phase 50 Hz induction motor has full load speed of 970 rpm. Calculate no of poles and slip frequency.

Last Answer : The number of poles in an induction motor can be calculated using the following formula: No. of poles = (120 * frequency) / speed In this case, the number of poles would be calculated as follows: No. of poles = ( ... ) - 50 Hz = 8.08 Hz So the motor has 6 poles and a slip frequency of 8.08 Hz.

Description : If a three-phase induction motor is operated under a light load and it develops an open in one of its supply lines, the motor will _____________. A. continue to run, but will vibrate and have reduced ... speed up due to the reduced number of poles C. run cooler due to reduced current flow D. stop

Last Answer : Answer: A

Description : A split-phase induction squirrel-cage motor will not come up to speed, even though the rated voltage, rated frequency, and rated load are applied. The suspected trouble could be due to _____________. A. a faulty centrifugal switch B. broken rotor bars C. worn bearings D. all of the above

Last Answer : Answer: D

Description : If the centrifugal switch or relay used for cutting out the starting winding of a split-phase induction motor fails to open once the motor is in operation, the _____________. A. motor will overspeed B ... C. motor will immediately stall under load D. motor torque will be above normal at rated speed

Last Answer : Answer: B

Description : The frequency of the rotor current in a 3 phase 50 Hz, 4 pole induction motor at full load speed is about (A) 50 Hz. (B) 20 Hz. (C) 2 Hz. (D) Zero.

Last Answer : (C) 2 Hz.

Description : The effect of increasing load on a synchronous motor running with normal excitation is (A) Increase both its Ia and power factor. (B) Decrease Ia, but increase power factor. (C) Increase Ia, but decrease power factor (D) Decrease both Ia and power factor.

Last Answer : The effect of increasing load on a synchronous motor running with normal excitation is Increase Ia, but decrease power factor

Description : If the synchronous speed of a 12 pole, polyphase, induction motor operating at 60 Hz were 600 RPM, how many poles will be required in a similar motor operating at the same frequency but having a synchronous speed of 900 RPM? A. 4 B. 6 C. 8 D. 18

Last Answer : Answer: C