Write the significance of load factor?

1 Answer

Answer :

Higher load factor means greater average load, resulting in greater number of units
generated for a given maximum demand. Thus, the standing charges, which are
proportional to maximum demand and independent of number of units generated, can be
distributed over a large number of units supplied and therefore overall cost per unit of
electrical energy generated will be reduced.

Related questions

Description : Define load factor.

Last Answer : Load factor is the ratio of average demand to the maximum demand during a certain period of time and is applicable to both generating equipment and receiving equipment. Load factor = Average demand/Maximum demand

Description : Write short note on load duration curve?

Last Answer : When the load elements of a load curve are arranged in the order of descending magnitudes, the curve thus obtained is called load duration curve. The load curve is obtained from the same data as ... the values of load factor and diversity factor, lower will be the overall cost per unit generated.

Description : What is the difference between base load and peak load?

Last Answer : The unvarying load which occurs almost the whole day is known as base load. The various demands of load over and above the base load is the peak load.

Description : What is mean by base load?

Last Answer : The unvarying load which occurs almost the whole day on the station is known as base load.

Description : What is load curve?

Last Answer : The curve showing the variation of load on the power station with reference to time is known as a load curve.

Description : What are the important types of power factor tariff?

Last Answer : (i) kVA maximum demand tariff (ii) sliding rate tariff (iii) kWh and kVAR tariff

Description : What is plant use factor?

Last Answer : It is defined as the ratio of kwh generated to the product of plant capacity and number of hours for which the plant is in operation.

Description : Define capacity factor.

Last Answer : It is the ratio of average demand to plant capacity

Description : What are the causes of low power factor?

Last Answer : The following are the causes of low power factor otors are of induction type which have low lagging power factor. These motors work at a power factor which is extremely small on light load 0 ... KW of all electrical devices installed at the consumer's premises and connected to the supply system.

Description : What do you mean by utilization factor?

Last Answer : It is a measure of the utility of the power plant capacity and is the ratio of maximum demand to the rated capacity of the power plant. It is always less than unity. Utilization factor = Maximum ... exceeds unity, it means that the load has been carried in excess of rated capacity of the plant.

Description : Define diversity factor.

Last Answer : Diversity factor is defined as the state of being dissimilar to one another. It is defined as the ratio of sum of the maximum demands of individual consuming units in a group during a specified period ... than one. If the diversity factor is higher, the cost per unit of generation will be lesser.

Description : What is three part tariff?

Last Answer : The total charge comprised of fixed charge made during billing period, charge per kW of maximum demand and charge per kWh of energy consumed.

Description : What are the important points to be taken into consideration while selecting the size and number of units?

Last Answer : variable demands from time to time. The nature of these demands can be seen from the load curve. The load variation is greater with a poorer load factor. units is per decided from the annual ... be a spare generating unit so that repairs and overhauling of the working units can be carried out.

Description : Define energy audit.

Last Answer : Energy Audit means studying the energy consumption pattern in the utilities or equipments by obtaining necessary data analyse the same to identify the areas where wastages or loses occur and suggest ... avoid wastages or loss and also other consumption measures to ensure efficient use of energy.

Description : What are the objectives of tariff?

Last Answer : Electrical energy is sold at such a rate so that it not only returns the cost but also earns reasonable profit. Therefore, a tariff must cover the following items: transmitting and distributing equipment. equipment. costs etc.

Description : What are the methods for determining depreciation charges?

Last Answer : The decrease in the value of the power plant equipment and building due to constant use is known as depreciation. The cost of depreciation will depend on the size and type of equipment ... equals the cost of equipment. The methods commonly used for determination of annual depreciation charges are

Description : Explain the term depreciation.

Last Answer : The decrease in the value of the power plant equipment and building due to constant use is known as depreciation. In practice, every power station has a useful life ranging from fifteen to thirty years ... of the plant. This reduction in the value of plant every year is known as annual depreciation.

Description : What do you mean by Economics of power generation?

Last Answer : The art of determining the per unit i.e. one KWh cost of production of electrical energy is known as Economics of power generation.

Description : What is the significance of load factor in electrical?

Last Answer : It helps to understand the behavior of the electrical system.Normally if rating of a device say a motor is 11 KW, it is notnecessary that it consumes 11 kw all the time. The loadingconditions may vary during its running.

Description : When load factor and diversity factor increases ___________ a) cost of electricity decreases b) cost of electricity also increases c) cost of electricity remains same d) cost of electricity increases exponential

Last Answer : Ans: A

Description : A transformer has negative voltage regulation when its load power factor is- (a) Zero (b) Unity (c) Leading (d) Lagging

Last Answer : Ans: C

Description : Three factors responsible for the change in voltage as load is applied to an AC generator are: 1) the drop in resistance in the armature circuit, 2) the change in flux, and 3) the ____________. A. armature winding speed B. inductance load drop C. coil pitch factor D. armature reactance voltage drop

Last Answer : Answer: D

Description : Which of the following statements is correct concerning the motor performance curves and data table shown in the illustration? EL-0006 A. The motor RPM at full load is 1737 RPM. B. The motor draws 12.62 kw ... If the motor was developing 10 HP its power factor would be 0.92. D. All of the above.

Last Answer : Answer: D

Description : If the excitation of an alternator operating in parallel is decreased below normal, its _____________. A. power factor will change in the lagging direction B. power factor will change in the leading direction C. ampere load will be greatly increased D. kilowatt load will be greatly decreased

Last Answer : Answer: B

Description : A three-phase alternator is operating at 450 volts, 250 amps at 0.6 power factor. If the power factor increases to 0.8, the kw load potential will increase by _____________. A. 38.525 kw B. 116.91 kw C. 155.88 kw D. 194.85 kw

Last Answer : Answer: A

Description : To remove an alternator operating in parallel with another unit from the main electrical bus, you must FIRST _________. A. adjust the power factor on both units B. set the desired voltage on ... C. open the circuit breaker on the outgoing alternator D. remove the load from the outgoing alternator

Last Answer : Answer: D

Description : After closing the circuit breaker to place two similar alternators in parallel, the NEXT step is to balance the _____________. A. power factor B. voltage load C. kilowatt load D. ampere load

Last Answer : Answer: C

Description : The true power indicated by a wattmeter depends on the current flow through the load, the magnitude of the potential across the load, and the _____________. A. power factor of the load B. angle of coil displacement C. inertia of the movable coil D. high resistance from the load

Last Answer : Answer: A

Description : The most practical way to control the voltage output of an AC generator is to vary the _____________. A. number of windings B. speed of the rotating field C. strength of the rotating magnetic field D. power factor of the load

Last Answer : Answer: C

Description : The operator of electrical motors should keep a constant check on the loads they carry because _____________. A. low loads necessitate frequent insulation cleaning B. exceeding nameplate values shortens ... wasted if full loading is not utilized D. power factor correction methods are load dependent

Last Answer : Answer: B

Description : Which of the following meters uses a shunt connected in series with the load, but parallel with the meter movement? A. voltmeter B. power factor meter C. wattmeter D. ammeter

Last Answer : Answer: D

Description : The true power indicated by the pointer movement of a wattmeter depends on the current flow through the load, the magnitude of the potential across the load, and the ____________. A. power factor of the ... B. angle of coil displacement C. inertia of the movable coil D. high resistance from the load

Last Answer : Answer: A

Description : Which of the listed meters uses a shunt connected in series with the load, but parallel with the meter movement? A. Voltmeter B. Power factor meter C. Ammeter D. Wattmeter

Last Answer : Answer: C

Description : The power factor of an AC generator operating singularly is determined by the __________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage

Last Answer : Answer: A

Description : If the excitation is increased to one of two alternators operating in parallel, the _____________. A. power factor will change in the lagging direction B. power factor will change in the leading direction C. kilowatt load will be greatly increased D. ampere load will be greatly decreased

Last Answer : Answer: A

Description : The power factor at which a paralleled AC generator operates is usually adjusted by the _____________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage

Last Answer : Answer: C

Description : To equalize the power factor of two alternators operating in parallel, the ____________. A. field excitation of both units is adjusted B. governors of both units are adjusted C. phase sequence is altered D. kilowatt load is evenly divided

Last Answer : Answer: A

Description : Using illustrated chart, when will the power factor be least efficient? EL-0006 A. When the motor is operating at full load. B. When the percentage of slip is greatest. C. When there is no load on the motor. D. the power factor is the same from no-load to locked rotor.

Last Answer : Answer: C

Description : Which of the following statements is true concerning all three-phase alternators? A. Each has three separate but identical armature windings acted on by one system of rotating magnets. B. Each has one ... The three phases always provide power to the load through three sets of slip rings and brushes.

Last Answer : Answer: A

Description : Regarding an AC generator connected to the main electrical bus; as the electric load and power factor vary, a corresponding change is reflected in the generator armature reaction. These changes in ... . governor speed droop setting B. voltage regulator C. balance coil D. phase-balance relay

Last Answer : Answer: B

Description : What is the power factor of an alternator at no load?

Last Answer : Answer:At no load Synchronous Impedance of the alternator is responsible for creating angle difference. So it should be zero lagging like inductor.

Description : Which power plant has high load factor?

Last Answer : Answer:All base load power plants have a high load factor. If we use high efficiency power plants to supply the base load,we can reduce the cost of generation.Hydel power plants have a higher efficiency than thermal & nuclear power plants.

Description : During No load why the power factor of the transformer is very low ?

Last Answer : Current flowing through the transformer consists of two components. Magnetizing current (Im) which is in quadrature (90 0 ) to the applied voltage and in phase current which is in phase to the applied voltage ... power factor of transformer during no load condition will by in the order of 0.1 to 0.2

Description : During No load why the power factor of the transformer is very low ?

Last Answer : A. Current flowing through the transformer consists of two components. Magnetizing current (Im) which is in quadrature (900) to the applied voltage and in phase current which is in phase to the applied voltage ... factor of transformer during no load condition will by in the order of 0.1 to 0.2

Description : Discuss the effect of acceleration factor in load flow study.

Last Answer : The acceleration factor is a real quantity and it modify the magnitude of voltage alone.

Description : What is the effect of increased load on power factor of induction motor?

Last Answer : Power factor of an induction motor increases with loading.

Description : Define the following: Average demand, Maximum demand, Demand factor, Load factor.

Last Answer : Average Demand: the average power requirement during some specified period of time of considerable duration is called the average demand of installation. Maximum Demand: The maximum demand of an installation ... Load Factor: It is defined as the ratio of the average power to the maximum demand.

Description : Which of the following plant is having lowest load factor? a) Diesel Plant b) Pumped storage Plant c) Thermal Plant d) Nuclear Plant

Last Answer : Ans: Diesel Plan

Description : A synchronous motor is operating on no-load at unity power factor. If the field current is increased, power factor will become (A) Leading & current will decrease (B) Lagging & current will increase. (C) Lagging & current will decrease. (D) Leading & current will increase.

Last Answer : Ans: A Initially synchronous motor is operating at no load and unity power factor. When field current increases, the excitation will increase. Therefore, p.f will be leading and current will be I CosĪ¦ < I

Description : A two-winding single phase transformer has a voltage regulation of 4.5% at full-load and unity power-factor. At full-load and 0.80 power-factor lagging load the voltage regulation will be (A) 4.5%. (B) less than 4.5%. (C) more than 4.5%. (D) 4.5% or more than 4.5%.

Last Answer : (C) more than 4.5%.