Which of the following statements concerning electrical cables is correct? A. Where they pass through watertight bulkheads, they should be fitted with watertight stuffing boxes. B. Electric cable coverings should never be grounded. C. Electrical cables must be rigidly held in place by welding of armored cable, or glued in place where nonmetallic insulation is used. D. All of the above.

1 Answer

Answer :

Answer: A  

Related questions

Description : All electric cables passing through watertight bulkheads must be _____________. A. installed with watertight stuffing tubes B. grounded on both sides of the bulkhead C. fitted with unions on each side of the bulkhead D. welded on both sides of the bulkhead

Last Answer : Answer: A

Description : When electrical cables penetrate watertight bulkheads, _______________. A. they should be grounded on either side of the bulkhead B. they must be bent to a radius of six diameters C. a watertight stuffing tube capable of accepting packing should be employed D. they should be secured by a clamp

Last Answer : Answer: C

Description : Which of the following is/are true concerning electric power operated watertight door systems? A. Each motor driven door must use the main bus as its source of power. B. Each distribution panel for ... to permit quick activation of the system. D. Each system must have a separate branch circuit.

Last Answer : Answer: D

Description : How many categories of nonmetallic protective coverings are there?

Last Answer : Three

Description : Which of the following statements best describes the material known as varnished cambric? A. Felted asbestos sealed with varnish. B. Cotton cloth coated with insulating varnish. C. Rubber ... Paper impregnated with mineral oil, specially wrapped with nonmetallic tape, and coated with varnish.

Last Answer : Answer: B

Description : Routine maintenance of dry-type transformers should include ____________. A. cleaning the windings, if accessible, with a vacuum cleaner or very low pressure air B. measuring and recording the winding ... . making sure that the units are close to bulkheads or corners to protect them from damage

Last Answer : Answer: A

Description : Which of the following statements is correct concerning the circuits in a sound powered telephone system? A. The ringing circuit is composed of only one common wire to ground. B. The common ... connected to each station. D. The talking and calling circuits are electrically dependent upon each other.

Last Answer : Answer: B

Description : Complete maintenance of electrical motors should include periodic checks for machine _____________. A. vibration B. watertight integrity C. speed droop D. reactive power

Last Answer : Answer: A

Description : Which of the following electric motors would be the safest and most reliable to use on the main deck of a vessel in foul weather conditions? A. Sealed motors B. Drip proof motors C. Enclosed motors D. Watertight motors

Last Answer : Answer: D

Description : According to Coast Guard Regulations (46 CFR), which of the following systems must be arranged so as to be energized by the final emergency power source? A. at least one light in the ... operated watertight door system C. each charging panel for temporary emergency batteries D. all of the above

Last Answer : Answer: D

Description : A stress which develops within an object when it attempts to expand or contract in response to a temperature changes, but cannot, due to being held rigidly in place.  a. elongation  b. thermal stress  c. expansion contraction  d. thermal expansion

Last Answer : thermal stress

Description : What is the most common type of nonmetallic material used to protect wires and cables?

Last Answer : Fibrous Braid.

Description : Copper is often used as an electrical conductor because it _______________. A. has high resistance at low temperatures B. has a highly polished surface C. is able to pass current with little opposition D. holds insulation together well

Last Answer : Answer: C

Description : While starting a main propulsion synchronous motor, the ammeter pegs out at maximum and then returns to the proper value after synchronization. This indicates the _____________. A. motor has started ... field windings are grounded C. slip rings are dirty D. power transmission cables are grounded

Last Answer : Answer: A

Description : What is the difference between flexible armored cable and flexible metal conduit?

Last Answer : Armored electrical cable contains insulated electrical servicewires protected by a flexible steel covering. Metallic Conduit is atube or pipe though which we lay electrical cable.(Most commonlylighting cables).

Description : In preparing to take insulation resistance readings on a main generator, the windings should be grounded for about 15 minutes prior to the test to _____________. A. allow accurate zeroing of the meter ... the windings D. help the windings to cool to the same temperature as the ground test connection

Last Answer : Answer: C

Description : When a megohmmeter is being used on a alternating current machine, the meter pointer will dip toward 'zero' and then gradually rise to the true resistance value if the motor insulation is _____________. A. grounded B. good C. shorted D. dirty

Last Answer : Answer: B

Description : Before testing insulation with a megohmmeter, the windings of large machines should be grounded for about 15 minutes just prior to the test as the ______________. A. insulation may be damaged ... number of leakage paths D. larger machines may acquire a charge of static electricity during operation

Last Answer : Answer: D

Description : Before testing insulation with a megohmmeter, the windings of large machines should be grounded for about 15 minutes just prior to the test, because the ___________. A. static charge of the machine ... number of leakage paths C. insulation may be damaged D. insulation may be covered with moisture

Last Answer : Answer: A

Description : In the cables, sheaths are used to (a) prevent the moisture from entering the cable (b) provide enough strength (e) provide proper insulation (d) none of the above

Last Answer : (a) prevent the moisture from entering the cable

Description : Accidental grounds in a shipboard electrical system must be repaired as soon as possible as they will ____________. A. result in immediate power outages B. damage circuit breakers C. appear on the ground detection system D. damage insulation and may cause outages

Last Answer : Answer: D

Description : A galvanometer is an instrument used to measure ___________. A. thickness of galvanized metal B. resistance of electrical wiring insulation C. very small amounts of current or voltage D. quantity of galvans in an electric circuit

Last Answer : Answer: C

Description : An insulation resistance test is performed on a particular piece of electric equipment. In addition to the resistance reading, what information listed below should be entered in the electrical log? A. ... D. The complete nameplate data from the resistance test instrument used to obtain the reading.

Last Answer : Answer: B

Description : What state of matter consists of particles held together firmly but not rigidly?

Last Answer : Feel Free to Answer

Description : Which of the following statements is true concerning a polyphase synchronous propulsion motor? A. The motor is started as an induction motor. B. Resistance is gradually added to the rotor circuit. C. ... is held below the rated current. D. The field winding is energized for starting purposes only.

Last Answer : Answer: A

Description : I want to sleep grounded. What is the difference between a bed pad, a half-sheet, and a fitted sheet? Is one more effective than the other?

Last Answer : In the Earthing book, we used the generic term bed pad to ed pad to describe a variety of Earthing sleep describe a variety of Earthing sleep systems developed by Clint Ober over the years. There are currently ... 3) the universal mat which can also be used on the floor or in floor or in the bed.

Description : What Is Meant By Insulation Voltage In Cables? Explain It?

Last Answer : It is the property of a cable by virtue of it can withstand the applied voltage without rupturing it is known as insulation level of the cable.

Description : The size of a conductor used in power cables depends on the (A) operating voltage. (B) power factor. (C) current to be carried. (D) type of insulation used.

Last Answer : (C) current to be carried.

Description : Which of the following statements is true concerning the cleaning of electrical contacts? A. Compressed air should be used to blow out metallic dust. B. Magnetic brushes should be used to remove ... contact resistance. D. Delicate parts should be cleaned with a brush and an approved safety solvent.

Last Answer : Answer: D

Description : During its operation, loud buzzing and resultant welding of contacts of a magnetic relay may be caused by __________. A. overheating of the contactor coil B. low voltage on the operating coil C. low insulation resistance to ground D. lubrication of the contact bearing points

Last Answer : Answer: B

Description : Coast Guard Regulations (46 CFR) require each switchboard to have ___________. A. non-conductive deck covering at the frount B. non-conductive deck coverings at the rear C. a name plate for each circuit breaker D. all the above

Last Answer : Answer: D

Description : What is the proper procedure for suppressing electrical noise in a mobile station? A. Apply shielding and filtering where necessary B. Insulate a all plain sheet metal surfaces from each other C. ... -static spray liberally to all nonmetallic D. Install filter capacitors in series with all dc wiring

Last Answer : A. Apply shielding and filtering where necessary

Description : The final step in testing a circuit for a ground involves the use of a megohmmeter. A grounded switch or cable will be indicated by a megohmmeter reading of ____________. A. 'zero' B. infinity C. steady in the high range D. unsteady in the low range

Last Answer : Answer: A

Description : A grounded switch or cable will be indicated by a megohmmeter reading of _____________. A. infinity B. 'zero' C. being unsteady in the high range D. being unsteady in the low range

Last Answer : Answer: B

Description : Explain briefly about armouring for an under grounded cable. 

Last Answer : Armouring is required to protect the cores from mechanical damage.  

Description : Which of the listed faults cannot be eliminated, EXCEPT by turning or grinding a commutator with a rigidly supported tool? A. Sparking brushes B. Eccentricity C. High mica D. Blackened commutator

Last Answer : Answer: B

Description : If deck machinery is expected to be idle for an extended period of time you should____________. A. have electrical safety gloves available in case of electrical shock before running B. perform ... run at regular intervals to inusre correct operation and to renew the internal coating of lubrication

Last Answer : Answer: D

Description : Air gap readings should be taken periodicly on electrical generation equipment to __________. A. determine the amount of varnish that can be applied to correct insulation problems B. determine the ... field coil bolts and correct lateral adjustment of the field coils D. increase machine efficiency

Last Answer : Answer: B

Description : Grounds occurring in electrical machinery as a result of insulation failure may result from _____________. A. deterioration through extended use B. excessive heat C. extended periods of vibration D. all of the above

Last Answer : Answer: D

Description : Why must the glass with paper glued to it be transparent?

Last Answer : Feel Free to Answer

Description : Which of the following statements is true concerning the operation of two alternators in parallel? A. The cycles per second of each alternator are the same. B. Both alternator governors must be set ... be the same on each alternator. D. The load must always be divided equally between alternators.

Last Answer : Answer: A

Description : Which of the following statements concerning nickel-cadmium batteries is true? A. When mixing electrolyte always add acid to the water. B. Nickel-cadmium batteries can be charged and ... The electrolyte of an idle nickel-cadmium battery must be replaced monthly to maintain battery condition.

Last Answer : Answer: C

Description : The proper way to apply plastic electrical tape to an electric cable splice is to _____________. A. apply tape to the braided cover, but avoid touching it B. wind the tape so that each turn overlaps ... tape in one non-overlapping layer only D. heat the tape with a soldering iron for good bonding

Last Answer : Answer: B

Description : The insulation between windings and grounded core and the insulation between the windings of the same phase is called (a) minor insulation (b) major insulation (c) either of the above (d) none of the above

Last Answer : (b) major insulation