What should I know before hiring a residential office mover?

1 Answer

Answer :

There are serveral things you should know before hiring a residential office mover. One concern is that the mover is licensed, bonded, and insured. That way, if items are lost or damaged you will be more likely to be compensated for your losses or damages. Additionally, check local review websites or the Better Business Bureau to see what kind of reputation a company has before entrusting your valuables to them.

Related questions

Description : What office work jobs are currently hiring in my area?

Last Answer : Well, there are many offices and buildings that are constantly looking for people to hire and recruiting employees. However, I would recommend attending a workshop to get better acquainted with the job.

Description : What should I know about a caterer before hiring them for a wedding?

Last Answer : Ask them about their rates. Try to find people who has experiences with caterers and ask them if they could suggest to you some of the one they have dealt with. Before you decide to hire a ... history. If that particular caterer has a good reputation for customer sercice, then you should hire them.

Description : What should I know before hiring an Accounting consultant?

Last Answer : You should know what the consultant's credentials are. Also, you might want to check their references from past employers.

Description : What kind of jobs require a background check before hiring?

Last Answer : The majority of jobs require a background check before hiring. Almost any job working with children will require one. Also any federal or state administered job requires a mandatory check. However, even your basic jobs like Shop Rite and McDonald's will require a background check.

Description : Questions to Ask Before Hiring a Sitter?

Last Answer : Hiring a sitter remains an important and stressful decision for parents. Before hiring anyone to watch your precious children, ask potential sitters seven questions to determine their experience and ... reliability and skill of a sitter then confidently enjoy a relaxing night on the town.

Description : Hiring House Painters Before Selling Your Home?

Last Answer : In today's economy, real estate in not selling the way it used to. The home seller needs to do everything he can to make his home more attractive to prospective buyers. One way he can do this is to hire ... is, a fresh coat of paint by a team of great house painters, might sell a home in less time!

Description : When you and another car come to an unmarked intersection in a residential area, and the other car gets there a few seconds before you do and stops, what do you do?

Last Answer : Totally unmarked ?Like no signage at all? no light, no stop sign, no yield sign? The other driver is treating it like a four way stop,which is safe, and probably expecting other drivers to do ... first driver was still playing safe to see if the other driver would stop or just plow right through.

Description : Long Distance Mover?

Last Answer : form_title=Long Distance Mover form_header=Are you ready for your new adventure? Leave the moving to the professionals when you are going a long distance. How many total miles is the move?=_ Do you have any large ... Yes () No () Not Sure When do you require the help of the long distance movers?=_

Description : The division of the reactive KVA load between paralleled AC generators is initiated by the ______________. A. prime mover governors B. voltage regulators C. phase balance relay D. proportioner

Last Answer : Answer: B

Description : Voltage failure of an AC generator may be caused by ____________. A. failure of the exciter generator B. a tripped bus circuit breaker C. high mica segments on the stator bus bar D. excessive prime mover speed

Last Answer : Answer: A

Description : The prime mover of an AC two pole main propulsion generator drives the generator at 3600 RPM. If the main propulsion motor has 80 poles, what will be the propeller speed? A. 45 RPM B. 80 RPM C. 90 RPM D. 180 RPM

Last Answer : Answer: C

Description : In the illustration, the signal from the device connected to terminals 18 and 19 is __________. EL-0046 A. prime mover speed feedback B. loss of control alarm when comparing with the input signal ... slip between the prime mover and the alternator D. to shut down the prime mover if overspeeding

Last Answer : Answer: A

Description : Which of the methods listed is used to start a AC generator turning? A. Residual magnetism remaining in the field poles. B. Residual magnetism remaining in the field coils. C. Residual magnetism remaining in the armature. D. Rotation by a mechanical prime mover.

Last Answer : Answer: D

Description : On electrical generators one of the bearings is isolated from the bedplate. This insulating block should not be painted and must be kept clean to ___________. A. protect operating personnel from shock ... the prime mover as it warms up D. eliminate shaft currents to prevent damaging the bearings

Last Answer : Answer: D

Description : If the bearings of an electrical generator are failing more frequently than expected and the lubricating oil is sludging then you should ______________. A. check the connections to the output leads B. ... replace the bearing with a sealed roller type D. replace the thrust bearing of the prime mover

Last Answer : Answer: B

Description : If air gap readings for an electical generating machine have changed significantly from the last reading, you should check _________. A. the bearings B. insulation readings and machine cleanliness C. the prime mover thrust bearing D. the field coil bolts for the proper torque values

Last Answer : Answer: A

Description : If the energy input is significantly reduced to the prime mover of one shipboard alternator operating in parallel with others, that alternator will _____________. A. continue to operate at no load B. lose ... overspeed C. begin to motorize and then trip out D. slow down and operate at reduced load

Last Answer : Answer: C

Description : In the illustration, the contacts between terminals 26 and 27 should be closed when _________. EL-0046 A. using one generator in isochronous mode only B. using two or more generators in ... through varying loads in parallel or single operation D. the circuit breaker is closed for that generator

Last Answer : Answer: C

Description : In the illustrated electronic governor, the circuit card connected to the potential and current transformers is for ________. EL-0046 A. increasing the signal strength to the governor to ... from motorization D. conditioning the load through the use of a magnetic amplifier current transformer

Last Answer : Answer: A

Description : A reverse-current relay will prevent AC generator motorization by ____________. A. automatically redirecting the load B. automatically speeding up the prime mover C. tripping the panel board main switch D. tripping the generator circuit breaker

Last Answer : Answer: D

Description : The voltage developed by an AC generator is controlled by varying the ____________. A. speed of the prime mover B. AC excitation to the field C. DC excitation to the field D. DC excitation of the voltage regulator

Last Answer : Answer: C

Description : Automatic voltage regulators provided on switchboards function to _____________. A. regulate the AC load on the generator B. protect the switchboard from high voltage C. govern prime mover speed to control voltage D. vary the field excitation to the generators

Last Answer : Answer: D

Description : The standard method of controlling the output voltage of a 440 volt, 60 Hz, AC generator is accomplished by adjusting the ____________. A. prime mover speed droop B. number of poles C. alternator field excitation D. load on the alternator

Last Answer : Answer: C

Description : The voltage output of an AC generator is accurately controlled by _____________. A. changing the sensitivity of the prime mover to large changes in voltage B. varying the reluctance of the air gap C. varying the DC exciter voltage D. shorting out part of the armature windings

Last Answer : Answer: C

Description : The power factor of an AC generator operating singularly is determined by the __________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage

Last Answer : Answer: A

Description : The power factor at which a paralleled AC generator operates is usually adjusted by the _____________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage

Last Answer : Answer: C

Description : To increase the frequency of an operating AC generator, you should ____________. A. increase the field excitation B. decrease the field excitation C. increase the number of magnetic poles D. increase the speed of the prime mover

Last Answer : Answer: D

Description : The frequency of an AC generator is adjusted by means of the ____________. A. main alternator field rheostat B. exciter field rheostat C. prime mover governor control D. equalizing reactor

Last Answer : Answer: C

Description : Prior to starting an AC generator prime mover, the voltage regulator cutout switch should be placed in the __________. A. manual position B. bus neutral position C. raise voltage position D. transfer position

Last Answer : Answer: A

Description : The output voltage of a 440 volt, 60 Hz AC generator is controlled by the ______________. A. load on the alternator B. load on the prime mover C. speed of the prime mover D. exciter output voltage

Last Answer : Answer: D

Description : As load is added to an AC generator provided with constant field excitation, the prime mover slows down with the effect of ____________. A. lowering frequency and lowering generated ... C. increasing frequency and lowering generated voltage D. lowering frequency and increasing generated voltage

Last Answer : Answer: A

Description : The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the _____________. A. voltage regulators B. field rheostats C. reverse power relays D. prime mover governors

Last Answer : Answer: D

Description : Kilowatt load is divided between two AC generators operating in parallel by _____________. A. adjusting the governor controls B. varying the excitation voltage C. increasing both prime mover speeds simultaneously D. decreasing both prime mover speeds simultaneously

Last Answer : Answer: A

Description : A constant output voltage from an AC generator is maintained by the _____________. A. prime mover governor B. exciter generator C. voltage regulator D. reverse power relay

Last Answer : Answer: C

Description : In an AC synchronous motor electric propulsion plant, propeller speed is controlled by varying the _____________. A. prime mover speed B. electric coupling field strength C. number of energized main motor poles D. propulsion generator field strength

Last Answer : Answer: A

Description : The output voltage of a 440 volt, 60 hertz, AC generator is controlled by the _____________. A. prime mover speed B. exciter output voltage C. load on the alternator D. number of poles

Last Answer : Answer: B

Description : What happens if speed of prime mover is changed keeping excitation of alternator constant?

Last Answer : If speed of prime mover is changed, the speed of alternator also changes hence frequency also changes. The frequency increase with increase in steam input and hence speed and vise versa.

Description : What happens if excitation of alternator is changed keeping speed of prime mover constant?

Last Answer : The emf induced will be changed and hence terminal voltage will also change. The terminal voltage will increase with increase in excitation and vise versa.

Description : A strategy that is best regardless of what rival players do is called a. First-mover advantage b. A Nash equilibrium strategy c. Tit-for-tat d. A dominant strategy

Last Answer : d. A dominant strategy

Description : is not well register, there is unbalance load, uneven harvesting and exclusive clogging of crops on the knife A) Vertical conveyor reaper B) MOVER C) Reaper binder D) Potato digger elevator.

Last Answer : MOVER

Description : The power developed in prime mover of power operated sprayer is a) 1 to 5 HP b) 5 to 10 HP c) 10 to 20 HP d) None of the above

Last Answer : 1 to 5 HP

Description : is the prime mover in which the direction of travel and its control for field operation is performed by the operator walking behind it. A. Power tiller C. Tillage B. Disc plough D. Rotary tiller

Last Answer : Power tiller

Description : . Tractor engine is used as A. General purpose C. Special purpose B. Prime mover. D. None of the above

Last Answer : Prime mover

Description : What type of prime mover requires a specially designed high-speed alternator?

Last Answer : Steam turbine.

Description : Why the concept of ‘Innovation’ is required in the business? a. To get first mover advantage b. Utmost Consumer Satisfaction c. To acquire larger market share d. All of the above

Last Answer : d. All of the above

Description : What is the significance of business environment? A. First Mover Advantage. B. Competition. C. Information. D. Globalization.

Last Answer : A. First Mover Advantage.

Description :  The driving power from the prime-mover driving the alternator is lost but the alternator remains connected to the supply network; the field supply also remains on. The alternator will: A) ... as a synchronous motor but will rotate in a reverse direction to that corresponding to generator action 

Last Answer : The driving power from the prime-mover driving the alternator is lost but the alternator remains connected to the supply network; the field supply also remains on. The alternator will: behave as a synchronous motor and will rotate in the same direction

Description : An 8 pole wound rotor induction motor operating on 60 Hz supply is driven at 1800 r.p.m. by a prime mover in the opposite direction of revolving magnetic field. The frequency of the rotor current is (a) 30 Hz (b) 60 Hz (c) 120 Hz (d) 180 Hz 

Last Answer : 30 Hz As the frequency of the rotor is given by  F= N*P/120 so from the above equation the frequency of the rotor current can be easily calculated  i.e. 1800×8/120=30 Hence the required value of rotor frequency is 30 Hz