is not well register, there is unbalance load, uneven harvesting and exclusive clogging of crops on the knife A) Vertical conveyor reaper B) MOVER C) Reaper binder D) Potato digger elevator.

1 Answer

Answer :

MOVER

Related questions

Description : To separate grains from the harvested crop and provide clean grain without much loss and damage which called as A) Potato digger elevator B) Groundnut digger shaker C) Reaper binder D) Threshing

Last Answer : Threshing

Description : A potato digger elevator can be mounted to a tractor with hp. a) 10-15 hp b) 20-25 hp c) 50-70 hp d) None of the above

Last Answer : 20-25 hp

Description : The main function of potato digger elevator is a) Digging of potatoes b) Windrowing of potatoes b) Both (A) & (B) c) None of these

Last Answer : Both (A) & (B)

Description : Vertical conveyor reaper is mostly used for paddy and………... b. Soybean c. Ground nut d. None of above

Last Answer : Ans-    a. wheat

Description : Capacity of vertical conveyor reaper is A) 0.1-0.9 ha/h B) 10-20 ha/h C) 0.4-0.6 ha/h D) 1-2 ha/h

Last Answer : 0.4-0.6 ha/h

Description : In vertical conveyor reaper, the crop to be harvested are guided by a) Star wheel b) Reel c) Row divider d) Cutter bar

Last Answer : Star wheel

Description : enght of cutter bar for the tractor operated mower or vertical conveyor reaper is..... (a) 1.5-3.0m (b) 3.0-4.5m (c)4.5-5.5m (d) >5.5m

Last Answer : (a) 1.5-3.0m

Description : Reaper is used for a.) Plowing b.) Harvesting and threshing. c.) Cutting crops. d.) Cutting and windrow.

Last Answer : d.) Cutting and windrow.

Description : Vertical transportation of materials can be done by a/an (A) Apron conveyor (B) Pneumatic conveyor (C) Bucket elevator (D) Both (B) & (C)

Last Answer : (D) Both (B) & (C)

Description : are the labelling of cutter bar. a) Shoe, ledger plate, wearing plate, knife, knife section, etc. b) Star wheel, engine, cage wheel, etc. c) both A & B d) Conveyor belt, cutter bar, rivers, etc

Last Answer : Shoe, ledger plate, wearing plate, knife, knife section, etc.

Description : It is a machine to cut herbage crops and leave them in a swath. b. thrasher c. Reaper. d. None of above

Last Answer : Ans-                                                                             a. Mower

Description : is the range of capacity of Vertical Conveyer reaper a) 0.1- 0.5 ha/h b) 0.4-0.6 ha/h c) 10-15 ha/h d) None of the above

Last Answer :  0.4-0.6 ha/h

Description : Harvesting of wheat with bullock drawn reaper and making bundles could require a) 2 persons b) 3 persons c) 4 persons d) 5 person

Last Answer : a) 2 persons

Description : Raw materials are charged in the iron blast furnace using (A) Bucket elevator (B) Skip hoist (C) Screw conveyor (D) None of these

Last Answer : (B) Skip hoist

Description : The most suitable equipment for the transportation of 200 mesh size particles is a (A) Bucket elevator (B) Pneumatic conveyor (C) Screw conveyor (D) Belt conveyor

Last Answer : (B) Pneumatic conveyor

Description : For transporting pasty material, one will use a/an (A) Apron conveyor (B) Belt conveyor (C) Screw conveyor (D) Bucket elevator

Last Answer : (C) Screw conveyor

Description : Which of the following mechanical conveyors does not come under the division ‘carriers’? (A) Belt conveyor (B) Bucket elevator (C) Screw conveyor

Last Answer : (C) Screw conveyor

Description : It is a machine designed for harvesting ,threshing,separating, cleaning and collecting grains while moving through standing crops. a. Weeder b. thresher d. None of above

Last Answer : Ans-          c. COMBINE

Description : machine designed for harvesting, threshing , cleaning and collecting grains while moving through standing crops. a) Combine b) Self operated VCR c) Power roller thresher d) Post harvesting technology

Last Answer : Combine 

Description : What is balanced load and unbalance load?

Last Answer : Balanced load In a three-phase system the power factors and the phase current or line currents of the 3-phase are equal, then that load is called balanced load. Unbalance load If the three-phases have different power factors and the phase current, then the load is called the unbalance load.

Description : in disc harrow, It prevents disc from clogging. a. Feeder c.Jointer d. None of the above.

Last Answer : Ans - b. Spacer

Description : This type blades in rotary tiller are Suitable for deep tillage in relatively clean ground, but clogging and wrapping of trashes on the tynes and shafts. a. L c. straight d. None of the above

Last Answer : Ans-  b. twisted

Description : prevents disc from clogging. i. Scraper. c) slide disc ii. Spikal tooth. d) spring tooth

Last Answer : Scraper

Description : Disc plough works in loose soil also without much clogging. a) True b) False

Last Answer : True

Description : Which of the following is the process of the pre-processing stage? a.Remove support b.Checking 3D CAD data c.De-powdering loose material d.Dip in a binder to strengthen the part

Last Answer : b.Checking 3D CAD data

Description : The reaper in a tractor can be raised or lowered by a) Mechanically b) Pneumatic system c) Hydraulic system d) Electric system

Last Answer : Hydraulic system

Description : Need for irrigation is on account of, A. Seasonal Rainfall. B. Uneven distribution of rainfall. C. Different water needs of crops. D. All the above.

Last Answer : D. All the above.

Description : How well known is that flushable wipes are clogging the sewers?

Last Answer : I thought I had “baby products” in topics box in there, I must have touched something by accident.

Description : The power developed in prime mover of power operated sprayer is a) 1 to 5 HP b) 5 to 10 HP c) 10 to 20 HP d) None of the above

Last Answer : 1 to 5 HP

Description : is the prime mover in which the direction of travel and its control for field operation is performed by the operator walking behind it. A. Power tiller C. Tillage B. Disc plough D. Rotary tiller

Last Answer : Power tiller

Description : . Tractor engine is used as A. General purpose C. Special purpose B. Prime mover. D. None of the above

Last Answer : Prime mover

Description : From the following which material handling equipment is used in Robot centered layout of FMS a.Industrial Robot b.Conveyor systems c.Rail guided vehicle system d.None of the above

Last Answer : a.Industrial Robot

Description : From the following which material handling equipment is used in ladder layout of FMS a.Conveyor systems b.AGVS c.Both A & B d.None of the above

Last Answer : c.Both A & B

Description : The division of the reactive KVA load between paralleled AC generators is initiated by the ______________. A. prime mover governors B. voltage regulators C. phase balance relay D. proportioner

Last Answer : Answer: B

Description : If the energy input is significantly reduced to the prime mover of one shipboard alternator operating in parallel with others, that alternator will _____________. A. continue to operate at no load B. lose ... overspeed C. begin to motorize and then trip out D. slow down and operate at reduced load

Last Answer : Answer: C

Description : In the illustrated electronic governor, the circuit card connected to the potential and current transformers is for ________. EL-0046 A. increasing the signal strength to the governor to ... from motorization D. conditioning the load through the use of a magnetic amplifier current transformer

Last Answer : Answer: A

Description : A reverse-current relay will prevent AC generator motorization by ____________. A. automatically redirecting the load B. automatically speeding up the prime mover C. tripping the panel board main switch D. tripping the generator circuit breaker

Last Answer : Answer: D

Description : Automatic voltage regulators provided on switchboards function to _____________. A. regulate the AC load on the generator B. protect the switchboard from high voltage C. govern prime mover speed to control voltage D. vary the field excitation to the generators

Last Answer : Answer: D

Description : The standard method of controlling the output voltage of a 440 volt, 60 Hz, AC generator is accomplished by adjusting the ____________. A. prime mover speed droop B. number of poles C. alternator field excitation D. load on the alternator

Last Answer : Answer: C

Description : The power factor of an AC generator operating singularly is determined by the __________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage

Last Answer : Answer: A

Description : The power factor at which a paralleled AC generator operates is usually adjusted by the _____________. A. connected load B. prime mover speed C. field excitation D. generator's rated voltage

Last Answer : Answer: C

Description : The output voltage of a 440 volt, 60 Hz AC generator is controlled by the ______________. A. load on the alternator B. load on the prime mover C. speed of the prime mover D. exciter output voltage

Last Answer : Answer: D

Description : As load is added to an AC generator provided with constant field excitation, the prime mover slows down with the effect of ____________. A. lowering frequency and lowering generated ... C. increasing frequency and lowering generated voltage D. lowering frequency and increasing generated voltage

Last Answer : Answer: A

Description : The division of the kilowatt load between two AC generators operating in parallel is controlled by the settings and characteristics of the _____________. A. voltage regulators B. field rheostats C. reverse power relays D. prime mover governors

Last Answer : Answer: D

Description : Kilowatt load is divided between two AC generators operating in parallel by _____________. A. adjusting the governor controls B. varying the excitation voltage C. increasing both prime mover speeds simultaneously D. decreasing both prime mover speeds simultaneously

Last Answer : Answer: A

Description : The output voltage of a 440 volt, 60 hertz, AC generator is controlled by the _____________. A. prime mover speed B. exciter output voltage C. load on the alternator D. number of poles

Last Answer : Answer: B

Description : Uneven wear of the commutator surface on a direct current propulsion motor can be caused by _____________. A. rapid change in load B. excessive operation at light load C. incorrect brush staggering D. unequal pole spacing

Last Answer : Answer: C

Description : The capacity of a belt conveyor depends upon two factors. If one is the cross-section of the load, the other is the __________ of the belt. (A) Speed (B) Thickness (C) Length (D) None of these

Last Answer : (A) Speed

Description : The purpose of providing expansion bellows in the shell of tubular exchanger is to (A) Increase the heating load (B) Impart structural strength (C) Account for the uneven expansion of shell and tube bundles (D) Facilitate increase of shell length, if needed

Last Answer : (C) Account for the uneven expansion of shell and tube bundles