1 Answer

Answer :

Large internal faults are protected by merz price percentage differential protection.

Related questions

Last Answer : Impedance relays are used for phase faults on long line.

Last Answer : A transmission line is protected by distance protection, time graded and current graded overcurrent protection.

Description : Thyristor can be protected from over voltages by using

Last Answer : Thyristor can be protected from over voltages by using Voltage clamping device

Description : Write down the steps involved for internal thread cutting on lathe machine.

Last Answer : Steps involved for internal thread cutting on lathe machine  1) Hole is first bored to the root diameter of the thread. 2) Tool is fixed on the tool post or on the boring bar adjusted the angle of ... the start. 10) Keep going until the calculated depth of cut has been reached on the top slide.

Description : List the types of Internal wiring in residential installations –

Last Answer : 1) Cleat wiring 2) Batten wiring 3) Wooden casing capping wiring 4) PVC conduit wiring 5) PVC casing capping wiring 6) Concealed wiring

Description : State the concept of internal voltage drop.

Last Answer : Concept of internal voltage drop: Every practical source offers some opposition to the current due to its internal parts or components. e.g. a 12V battery has electrodes made up of conducting ... internal voltage drop, the terminal voltage of practical voltage source is always less than its emf. 

Description : Define the following terms as referred to battery. a) E.M.F b) Internal resistance c) Ah efficiency d) WAh efficiency

Last Answer : a) E.M.F : The electromotive force of a battery is defined as the energy spent or the work done in taking a unit positive charge around the complete circuit of the battery i.e., in ... input required to restore the initial state of charge, under specified conditions, is called Watt-hr efficiency.

Description : What is internal voltage drop and terminal voltage?

Last Answer : It is not permissible to just connect the positive terminal to the negative terminal of a cell with a copper wire. It will overheat and get damaged. This happens because the electromotive force (emf) ... than the nominal voltage (emf) of the cell and this lower voltage is called terminal voltage.

Description : The internal resistances of an ideal current source, and an ideal voltage source are, respectively, (A) 0, ∞ (B) ∞, ∞ (C) ∞, 0 (D) 0,0

Last Answer : The internal resistances of an ideal current source, and an ideal voltage source are, respectively, ∞, 0

Description : Sketch internal design of 4x3 ROM.

Last Answer : The internal design of 4x3 ROM

Description : For maximum transfer of power, internal resistance of the source should be?

Last Answer : For maximum transfer of power, internal resistance of the source should be equal to load resistance.

Last Answer : Yes BJT have internal capacitances.

Description : EPROM internal structure

Last Answer : EPROM (Erasable Programmable ROM): EPROM stands for Erasable Programmable ROM.Data is stored in EPROM memory cell as an electrostatic charge on highly insulated conductor. The charge can remain for ... figure shows EPROM memory cell consisting of a single NMOS filed effect transistor. 

Description : Large internal faults are protected by (a) merz price percentage differential protection (b) mho and ohm relays (c) horn gaps and temperature relays (d) earth fault and positive sequence relays

Last Answer : (a) merz price percentage differential protection

Description : State and explain the faults occur in the transformers.

Last Answer : Sr. No. Type of fault Explanation 1 Earth fault Due to breakdown of insulation between live conducting parts such as winding, terminals etc. and earthed metallic parts such as ... place and few turns of the same winding are shortcircuited, the inter-turn fault takes place.

Description : What are causes of faults in power system? State any four harmful effects of faults.

Last Answer : Causes of Faults in the Power System:  1) Breaking of Conductors: It is one of major causes of faults. Breaking of conductors is due to excessive heat or because of mechanical stresses ... maintenance of machines / equipment / lines / protective system leads to faults in the power system.

Description : Protection of transformer from all types of faults is by using (A) over current relay (B) differential relay (C) distance relay (D) Buchholz relay

Description : Reactance relays are employed for Phase faults in : (A) Short lines (B) Medium lines (C) Long lines (D) Any line

Last Answer : Reactance relays are employed for Phase faults in : Short lines

Description : Ungrounded neutral transmission system is not recommended because of system (a) insulation being overstressed due to over voltages (b) insulation overstress may lead to failure and subsequent phase to phase faults (c) being inadequately protected against ground fault (d) all of the above

Last Answer : (d) all of the above

Description : How the alternator can be protected from inter-turn fault?

Last Answer : Inter-turn fault Protection: Figure shows scheme for one phase only. It is identical for other phases. Under normal working condition, the two currents in the stator winding sections (S1 and S2) are ... relay coil to operate it, leading to isolation of the alternator from the power system.

Description : How Transformer Protection provided for internal faults?

Last Answer : 1.Bucholz Relay (1st Stage Alarm and 2nd Stage Trip) 2.Sudden Pressure Relay (1st Stage Alarm and 2nd Stage Trip) 3.Pressure Relief Valve (1st Stage Alarm and 2nd Stage Trip) 4.Pressure Switch ... 8.Gas Temperature Indicator (Alarm) 9.Silicon Breather (Passive - no alarm) 10.Smoke Detector (Alarm)

Description : What are the tests done to minimize internal faults?

Last Answer : 1.Dissolved Gas Analysis (DGA): Faults due to arcing, high current breakdown of oil, localized sparking, partial discharge of oil, localized overheating or hot spots, etc. causes ... Over current relays with under voltage blocking 6.Zero sequence protection. 7.Negative phase sequence protection

Description : Protection scheme for internal faults in a three phase star delta connected transformer

Description : Differential relays detect internal faults in 3-phase transformers by (A) zero sequence currents (B) positive sequence currents (C) negative sequence currents (D) both positive and negative sequence currents

Description : For internal faults in generator, the primary protection is provided by (1) Earth fault relay (2) Differential relay (3) Induction type inverse definite minimum time relay (4) Definite minimum time relay 

Description : Python Scipy : Segmentation Faults when slicing (splitting into train and test sets) large csr_matrix -Web-Development

Last Answer : answer:

Description : What type of mountains form at large-scale normal faults where the footwall and hanging wall spread apart from each other?

Last Answer : What is the answer ?

Description : Describe the accessibility modifier “protected internal”. 

Last Answer : It is available to classes that are within the same assembly and derived from the specified base class.

Description : What is protected internal accessibility?

Last Answer : Access is restricted to types derived from the containing class or from files within the same assembly.

Description : Describe the accessibility modifier “protected internal”. 

Last Answer : It is available to classes that are within the same assembly and derived from the specified base class.

Description : Describe the accessibility modifier protected internal. 

Last Answer : It’s available to derived classes and classes within the same Assembly (and naturally from the base class it’s declared in). 

Description : 8096 write-protected mode, no code can write to memory address between __. a) 2020 to 3FFFH b) 8000 to FFFFH c) 2000 to 3FFFH d) 2020 to 202FH 17. If the __ pin is ___ , then we have the option ... b) EA, low, internal, external c) EA, high, external, internal d) EA, low, external, internal

Last Answer : c) EA, high, external, internal

Description : A loss of excitation protection scheme for large generating unit employs A) under frequency relays B) offset Mho relay C) reactance relay D) percentage differential relay

Last Answer : A loss of excitation protection scheme for large generating unit employs offset Mho relay

Last Answer : Interruption of large currents by relay requires arc suppressing blow out coils, wide separation of the opened contacts, high speed opening of contacts.

Description : A large size synchronous generator is protected against overloads by   (a) over current relay (b) mho relay (c) temperature sensitive relay (d) Buchholz relay

Description : Write faults of cable TV.

Description : Write general kind of faults with the recorder/player.

Description : What are the faults and how will you rectify them if a DC shunt motor does not start?

Description : Is it true that it's hard for people to realize their own faults?

Last Answer : I still think you should have just taken it back to the school that you took it from. I wouldn't have taken someone else's bag home to begin with. Maybe she isn't the only one not seeing ... or face them. Sometimes they realize their faults some time after the event. Hindsight is 20/20, you know.

Description : Are you willing to admit your driving faults?

Last Answer : answer:I have poor peripheral vision, as well as dyscalculia - which affects my ability to distinguish left from right, as well as accurately judge distance. As a result, I am an exceptionally cautious ... a garage spot and walk an extra block than park on the street in front of my destination.