Please Log in or Register for more.


123 views

1 Answer

Answer :

For starting a D.C. motor a starter is required because it limits the starting current to a safe value.

Like 0 like

Please log in or register to answer this question.

Related Questions


Why starter is required for starting an induction motor?

Show More

114 views 0 answers








Last Answer : A direct online starter is used for starting motors up to 5 H.P.

Show More

83 views 1 answer








Last Answer : The starting resistance of a D.C. motor is generally low.

Show More

169 views 1 answer







Explain the necessity of starter for D.C. motor. State various types of D.C. motor starter. 
Last Answer : Necessity of Starter for D.C. Motor: Armature current is given by equation Ia = (V−Eb)/Ra i) If the motor is at standstill or rest, back emf Eb is zero (as Eb= ZNP/(60A), at start speed N ... . Types of D.C. motor starters: i) Two point starter ii)Three point starter iii) Four point starter

Show More

305 views 1 answer







Which type of starter is used to start the DC motor?

Show More

77 views 0 answers







Why a dc series motor has a high starting torque?
Last Answer : motor

Show More

86 views 1 answer







In a double squirrel cage induction motor, good starting torque is produced as (A) Large current flows through the outer high resistance winding. (B) Large current flows through the inner high ... the outer high resistance winding. (D) Large current flows through the inner low resistance winding.
Last Answer : In a double squirrel cage induction motor, good starting torque is produced as Large current flows through the outer high resistance winding.

Show More

136 views 1 answer








Last Answer : For the same H.P. rating and full load speed, following motor has poor starting torque differentially compounded.

Show More

164 views 1 answer








Last Answer : The starting winding of a single-phase motor is placed in stator.

Show More

115 views 1 answer








Last Answer : If starting winding of a single-phase induction motor is left in the circuit, it will draw excessive current and overheat.

Show More

234 views 1 answer








Last Answer : Starting winding of a single phase motor of a refrigerator is disconnected from the circuit by means of a magnetic relay.

Show More

215 views 1 answer







How is a three phase cage induction motor self starting?
Last Answer : Any type of induction motor is self starting. Because the reason for torqe production require two flux displaced by some angle theta.If theta is constant with time then torqe will be constant;if ... torqe also pulsating. In induction motor this angle theta is not pulsating.so it is self starting 

Show More

158 views 1 answer







Is induction motor is self starting?
Last Answer : Single phase induction motor is not self starting. Three phase induction motor is self starting.

Show More

111 views 1 answer








Last Answer : Capacitor start motor has high torque in starting

Show More

133 views 1 answer








Last Answer : In a manual shunt motor starter over load relay is connected in series and no volt relay in parallel with the load.

Show More

76 views 1 answer







List different starting methods of three phase synchronous motor. Explain any one of them.
Last Answer : Different Starting Methods of Three Phase Synchronous Motor: As synchronous motor is not self starting, different methods of starting are as follows: 1) By using an Induction (Pony) motor 2) ... . The rotor gets pulled into synchronism and starts running at constant speed as a synchronous motor. 

Show More

157 views 1 answer








Last Answer : The value of starting capacitor of a fractional horse power motor will be 300 uF .

Show More

98 views 1 answer








Last Answer : A centrifugal switch is used to disconnect starting winding when motor has picked up about 50 to 70 per cent of rated speed.

Show More

875 views 1 answer








Last Answer : The rotor developed by a single-phase motor at starting is zero.

Show More

89 views 1 answer








Last Answer : In a capacitor start motor, the phase displacement between starting and running winding can be nearly 90°.

Show More

207 views 1 answer







A synchronous motor can be made self starting by providing?
Last Answer : A synchronous motor can be made self-starting by providing damper bar.

Show More

131 views 1 answer







Why does induction motor have high starting current?
Last Answer : In induction motor , the flux produce is quadrature to the applied voltage. Since when we are going to start motor , there is no flux present inside . So in order to lets say compensate it ... times of current to further increase flux. So that is reason for high starting current in induction motor

Show More

143 views 2 answers








Last Answer : At the instant of starting when a D.C. motor is put on supply, it behaves like a low resistance circuit.

Show More

130 views 1 answer







As there is no back e.m.f. at the instant of starting a D.C. motor, in order to prevent a heavy current from flowing though the armature circuit?
Last Answer : As there is no back e.m.f. at the instant of starting a D.C. motor, in order to prevent a heavy current from flowing though the armature circuit a resistance is connected in series with armature.

Show More

187 views 1 answer








Last Answer : Three point starter can be used for both shunt and compound motor.

Show More

98 views 1 answer








Last Answer : A three point starter is considered suitable for shunt as well as compound motors.

Show More

185 views 1 answer







What is an auto transformer starter?

Show More

70 views 0 answers








Last Answer : Sparking, is discouraged in a D.C. motor because commutator gets damaged.

Show More

159 views 1 answer







Describe the reason of using dc series motor for electric trains.
Last Answer : Electric trains require an inverse torque speed characteristics for proper operation. That is a higher torque is required at start (when speed is nil or low) and as the train picks up ... torque - speed characteristics of DC series motors match, these motors are suitable for electric trains

Show More

142 views 1 answer







A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be
Last Answer : A 240 V, dc shunt motor draws 15 A while supplying the rated load at a speed of 80 rad/s. The armature resistance is 0.5 W and the field winding resistance is 80 W. The net Voltage across armature resistance at the time of plugging will be 474 V

Show More

481 views 1 answer







A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is
Last Answer : A 200 V dc shunt motor is running at 1000 rpm and drawing a current of 10 A. Its armature winding resistance is 2 Ohm. It. is braked by plugging. The resistance to be connected in series with armature to restrict armature current to 10 A, is 36 Ohm

Show More

331 views 1 answer







In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is :
Last Answer : In a 2 kW, 200 V, 1000 rpm. DC series motor the torque at full load was found to be 0.3 N -m. The torque at half full load in N -m is : 0.075

Show More

109 views 1 answer







The function of a brush and commutator arrangement in a dc motor is to  (1) produce unidirectional torque (2) produce unidirectional current in the armature (3) help in changing the direction of rotation of the armature (4) reduce sparking
Last Answer : The function of a brush and commutator arrangement in a dc motor is to produce unidirectional torque

Show More

2.5k views 1 answer








Last Answer : If a D.C. motor designed for 40°C ambient temperature is to be used for 50°C ambient temperature, then the motor is to be derated by a factor recommended by manufacturer and select the next higher H.P. motor.

Show More

97 views 1 answer








Last Answer : For a D.C. shunt motor if the excitation is changed torque will change but power will remain constant.

Show More

168 views 1 answer







The speed of a D.C. motor can be controlled by varying  1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above
Last Answer : The speed of a D.C. motor can be controlled by varying  1. Its flux per pole 2. Resistance of armature circuit 3. Applied voltage 4. All of the above

Show More

389 views 1 answer








Last Answer : In case the back e.m.f. and the speed of a D.C. motor are doubled, the torque developed by the motor will remain unchanged.

Show More

228 views 1 answer








Last Answer : The speed of a D.C. shunt motor can be increased by increasing the resistance in field circuit.

Show More

134 views 1 answer








Last Answer : The armature voltage control of D.C. motor provides constant torque drive.

Show More

92 views 1 answer








Last Answer : The armature torque of the D.C. shunt motor is proportional to armature current.

Show More

210 views 1 answer








Last Answer : As the load is increased the speed of D.C. shunt motor will reduce slightly.

Show More

142 views 1 answer








Last Answer : In a differentially compounded D.C. motor, if shunt field suddenly opens the motor will first stop and then run in opposite direction as series motor.

Show More

94 views 1 answer








Last Answer : Flywheel is used with D.C. compound motor to reduce the peak demand by the motor, compound motor will have to be cumulatively compounded.

Show More

353 views 1 answer








Last Answer : D.C. Series motor is generally preferred for cranes and hoists.

Show More

120 views 1 answer








Last Answer : (b) Clostridium butylicum Lipase Removal of oil stains

Show More

107 views 1 answer








Last Answer : Sparking at the commutator of a D.C. motor may result in damage to commutator segments, damage to commutator insulation, increased power consumption.

Show More

228 views 1 answer








Last Answer : If a D.C. shunt motor is working at no load and if shunt field circuit suddenly opens this will result in excessive speed, possibly destroying armature due to excessive centrifugal stresses.

Show More

122 views 1 answer








Last Answer : Cumulatively compounded D.C. motor will be suitable along with flywheel for intermittent light and heavy loads.

Show More

175 views 1 answer








Last Answer : Differentially compounded D.C. motor has got maximum self loading property.

Show More

77 views 1 answer








Last Answer : The current drawn by the armature of D.C. motor is directly proportional to the torque required.

Show More

582 views 1 answer






Show More⇦ PreviousNext ⇨