1 Answer

Answer :

In a separately excited generator supplying rated load the armature reaction is always present.

Related questions

Description : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ (A) directly proportional to α and Φ (B) ... proportional to α and inversely proportional to Φ (D) directly proportional to Φ and inversely proportional to α

Last Answer : The no-load speed of a single-phase SCR bridge converter fed separately excited dc motor operating at a firing delay angle, α and flux, Φ directly proportional to α and inversely proportional to Φ

Description : A separately excited dc motor operating in first quadrant is fed from 3-phase semi -converter free -wheeling diode is open circuited, then the motor :  (A) can be operated in first quadrant (B) ... in first & second quadrants (C) can be operated in first & fourth quadrants (D) cannot be operated

Last Answer : A separately excited dc motor operating in first quadrant is fed from 3-phase semi -converter free -wheeling diode is open circuited, then the motor : can be operated in first & fourth quadrants

Description : Separately Excited DC motor

Last Answer : Separately Excited DC motor

Last Answer : A separately excited generator as compared to a self-excited generator is amenable to better voltage control, more stable, has exciting current independent of load current.

Description : The armature reaction in a synchronous generator supplying leading power factor load is (A) magnetizing (B) demagnetizing (C) demagnetizing and cross-magnetizing (D) magnetizing and cross-magnetizing

Last Answer : The armature reaction in a synchronous generator supplying leading power factor load is magnetizing and cross-magnetizing

Last Answer : Armature reaction in a generator results in demagnetisation of leading pole tip and magnetisation of trailing pole tip.

Last Answer : The demagnetising component of armature reaction in a D.C. generator reduces generator e.m.f.

Description : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave?

Last Answer : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave will be of 5 Hz.

Description : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be?

Last Answer : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be 580 V.

Last Answer : The armature core of a D.C. generator is usually made of silicon steel.

Description : For a D.C. generator when the number of poles and the number of armature conductors is fixed, then which winding will give the higher e.m.f. ?

Last Answer : Wave winding

Description : If the load of the normally excited synchronous motor is increased the power factor will?

Last Answer : If the load of the normally excited synchronous motor is increased the power factor will become lagging.

Last Answer : In a level compounded D.C. generator, full load terminal voltage is equal to no-load terminal voltage.

Last Answer : In over compounded generator, full load terminal voltage is more than no load terminal voltage.

Last Answer : An over excited synchronous motor on noload is known as synchronous condenser.

Description : Why synchronous machine is called doubly excited machine?

Last Answer : Armature windings of synchronous machines either deliver 3 phase AC or absorb 3 phase AC source,  whereas field windings are energized from DC source. Thus due to presence of AC on armature and DC on field windings, synchronous machines are often referred as doubly excited machines.

Description : If the field of synchronous motor is under excited, power factor will be?

Last Answer : If the field of synchronous motor is under excited, power factor will be lagging.

Description : A large AC generator, supplying power to an infinite bus, has a sudden short-circuit occurring at its terminals. Assuming the prime mover input and the voltage behind the transient reactance to remain constant immediately after the fault, acceleration of the generator rotor is

Last Answer : A large AC generator, supplying power to an infinite bus, has a sudden short-circuit occurring at its terminals. Assuming the prime mover input and the voltage behind the transient reactance ... , acceleration of the generator rotor is inversely proportional to the moment of inertia of the machine

Last Answer : The critical resistance of the D.C. generator is the resistance of field.

Description : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be?

Last Answer : If residual magnetism is present in a D.C. generator, the induced e.m.f. at zero speed will be zero.

Last Answer : A 220 V D.C. generator is run at full speed without any excitation. The open circuit voltage will be about 2 V.

Last Answer : In case of a flat compounded generator voltage remains constant irrespective of the load.

Last Answer : An exciter for a turbo generator is a shunt generator.

Last Answer : In a D.C. generator in case the resistance of the field winding is increased, then output voltage will decrease.

Last Answer : A D.C. generator can be considered as rotating amplifier.

Last Answer : A cumulatively compounded long shunt generator when operating as a motor would be differentially compounded long shunt.

Last Answer : In a D.C. generator, the critical resistance refers to the resistance of field.

Last Answer : Flashing the field of D.C. generator means creating residual magnetism by a D.C. source.

Last Answer : If a D.C. generator fails to build up the probable cause could not be field resistance less than the critical resistance.

Description : The purpose of providing dummy coils in a generator is?

Last Answer : The purpose of providing dummy coils in a generator is to provide mechanical balance for the rotor.

Description : A shunt generator running at 1000 r.p.m. has generated e.m.f. as 200 V. If the speed increases to 1200 r.p.m., the generated e.m.f. will be nearly?

Last Answer : 200V/E2 = 1000/1200 E2= 240 V

Last Answer : In a D.C. generator the magnetic neutral axis coincides with the geometrical neutral axis, when there is no load on|he generator.

Last Answer : The e.m.f. generated in a D.C. generator is directly proportional to speed of armature.

Last Answer : In a D.C. generator the number of mechanical degrees and electrical degrees will be the same when number of poles is 2.

Last Answer : D.C. generator generally preferred for charging automobile batteries is long shunt compound generator.

Last Answer : In a D.C. generator the ripples in the direct e.m.f. generated are reduced by using carbon brushes of superior quality.

Last Answer : Welding generator will have lap winding.

Last Answer : If brushes of a D.C. generator are moved in order to bring these brushes in magnetic neutral axis, there will be crossmagnetisation as well as demagnetising.

Last Answer : In case of a 4-pole D.C. generator provided with a two layer lap winding with sixteen coils, the pole pitch will be 8.

Last Answer : In a D.C. generator, the iron losses mainly take place in armature rotor.

Last Answer : The condition for maximum efficiency for a D.C. generator is variable losses equal to constant losses.

Last Answer : The total losses in a well designed D.C. generator of 10 kW will be nearly 500 W.

Description : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is

Last Answer : A 200 V DC machine supplies 20 A at 200 V as a generator. The armature resistance is 0.2 Ohm. If the machine is now operated as a motor at same terminal voltage and current but with the flux increased by 10%, the ratio of motor speed to generator speed is 0.87

Description : Why is the armature of DC generator laminated?

Last Answer : The armature of DC generator is laminated to reduce eddy current losses.

Last Answer : In D.C. generators on no-load, the air gap flux distribution in space is flat topped.

Description : The fall in speed of a dc generator due to increase in load can be corrected by  (1) cooling the armature.. (2) increasing the excitation. (3) reducing the load voltage. (4) increasing the input to the prime mover

Last Answer : It   can  be  corrected  by  increasing  the  input  to  the  prime  mover.

Description : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load  (A) The armature current increases and the power factor decreases  (B) The armature ... but is lagging  (D) The armature current decreases and the power factor increases and is leading

Last Answer : In a synchronous generator if the excitation increased from a low value to normal value, with a fixed load The armature current decreases and the power factor increases and is leading

Description : In a synchronous generator delivering lagging power factor load  (1) the excitation emf leads terminal voltage by the power angle (2) the excitation emf lags terminal voltage by the power angle (3) ... by the power factor angle (4) excitation emf lags the terminal voltage by the power factor angle

Last Answer : In a synchronous generator delivering lagging power factor load the excitation emf leads terminal voltage by the power angle

Description : What Do You Think About Your Solia Flat Iron?

Last Answer : Ask on Craigslist BeFo. Your odds of getting a meaningful response would seem to be better there. Really, flat irons are pretty simple devices. They just produce heat and transfer it to the iron surface. ... of years. I think that is a pathetic life span for such a simple device. Just saying.