What are the reason of fall of terminal voltage of a D.C.Shunt generator?

1 Answer

Answer :

As the load current increases, the terminal voltage tends todrop due to increased current and drop in voltage due to internalwinding resistance.

Related questions

Description : The simplest method of controlling the terminal voltage of compound-wound DC generator is with a _____________. A. hand-operated field rheostat connected in series with the shunt field circuit B. ... in series with the load D. balance coil diverting neutral current through the shunt field

Last Answer : Answer: A

Description : A dc shunt generator has a speed of 800 rpm when delivering 20 A to the load at the terminal voltage of 220V. If the same machine is run as a motor it takes a line current of 20A from 220V supply. The speed of ... . (B) more than 800 rpm. (C) less than 800 rpm. (D) both higher or lower than 800 rpm.

Last Answer : (C) less than 800 rpm.

Description : The terminal voltage of a DC shunt generator drops on load because of all of the following except : (A) Armature reaction (B) Armature resistance drop (C) Commutation (D) Field weakening due to armature reaction and armature resistance drop

Last Answer : (D) Field weakening due to armature reaction and armature resistance drop

Description : An open shunt field in a direct current machine may be located by connecting the field circuit to an external power source, equal to the rated field voltage or less, and tested with a voltmeter from ... C. any suitable ground to any available line lead D. any field pole to each field coil lead

Last Answer : Answer: A

Description : One method of testing for a reversed shunt field coil in a DC generator or motor is by connecting the field to a direct current source, at reduced field rated voltage, and test for ... placed near each field C. test lamp across adjacent fields D. copper jumper across the interpole connections

Last Answer : Answer: B

Description : Shunt generator gives full voltage on load and the voltage drop as the load on the generator a. Decreases b. Increases c. Remains the same d. None of above 

Last Answer : Shunt generator gives full voltage on load and the voltage drop as the load on the generator a. Decreases b. Increases c. Remains the same d. None of above 

Description : A shunt generator develops stable output voltage if (A) magnetization characteristic is linear (B) magnetization characteristic is non-linear (C) the field winding resistance is more than the critical resistance (D) the residual magnetism is equal to zero

Last Answer : A shunt generator develops stable output voltage if magnetization characteristic is non-linear

Description : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave?

Last Answer : A sinusoidal voltage of 5 Hz is applied to the field of a shunt generator. The armature voltage wave will be of 5 Hz.

Description : When paralleling two alternators using three synchronizing lamps, the flickering of all three lamps becomes progressively slower and slower. This means the ______________. A. frequency of the incoming ... the bus D. terminal voltage of the incoming alternator is approaching that of the bus

Last Answer : Answer: A

Description : Which of the terms listed best describes a compound-wound DC generator having a higher voltage at no load than at full load? A. Flat compounded B. Over compounded C. Under compounded D. Terminal compounded

Last Answer : Answer: C

Description : A compound generator has a no-load voltage of 250 volts and a full-load voltage of 230 volts, and therefore, is considered to be _____________. A. flat compounded B. over compounded C. under compounded D. terminal compounded

Last Answer : Answer: C

Description : What are the factors, which varies terminal voltage of generator?

Last Answer : a) Voltage drop due to resistance (Ra drop). This is negligible. b) Voltage drops due to leakage reactance (XL). c) Voltage drops due to armature reaction. 

Last Answer : In a level compounded D.C. generator, full load terminal voltage is equal to no-load terminal voltage.

Last Answer : In over compounded generator, full load terminal voltage is more than no load terminal voltage.

Description : Which of the listed electrical devices is represented by the symbol shown in the illustration? EL-0055 A. Fixed resistance resistor B. Coil with magnetic core C. DC motor or generator shunt field D. Transformer

Last Answer : Answer: D

Description : A shunt-wound DC generator is one in which the shunt field windings are in parallel with the _____________. A. commutator B. brushes C. armature D. all of the above

Last Answer : Answer: D

Description : A DC shunt generator has its field windings connected in _____________. A. series with the series windings B. parallel with the field rheostat C. series with the armature windings D. parallel with the armature windings

Last Answer : Answer: D

Description : A variable shunt, connected across the series field coils of a DC compound wound generator, to permit adjustment of the degree of compounding, is called a _____________. A. divider B. diverter C. converter D. rheostat

Last Answer : Answer: B

Description : A booster is a (a) series wound generator (b) shunt wound generator (c) synchronous generator (d) none of the above

Last Answer : (a) series wound generator

Description : A booster is a (a) series wound generator (b) shunt wound generator (c) synchronous generator (d) none of the above

Last Answer : (a) series wound generator

Description : Draw the connection diagram of long shunt differential D.C. compound generator.

Last Answer : Ans:

Description : To conduct load test on a dc shunt motor, it is coupled to a generator which is identical to the motor. The field of the generator is also connected to the same supply source as the motor. The armature of generator is ... value of this load resistance is  (A) 1.0 (B) 0.98 (C) 0.96 (D) 0.94

Last Answer : To conduct load test on a dc shunt motor, it is coupled to a generator which is identical to the motor. The field of the generator is also connected to the same supply source as the motor. ... obtain rated armature current in both motor and generator. The p.u value of this load resistance is 0.96

Description : The external characteristic of a shunt generator can be obtained directly from its – characteristic   1. internal 2. open-circuit 3. load-saturation 4. Performance 

Last Answer : The external characteristic of a shunt generator can be obtained directly from its open-circuit characteristic

Description : In a DC shunt generator working on load, the brushes are moved forward in the direction of rotation, as a result of this, commutation will   (a) Improve but terminal voltage will fall   (b) ... will fall   (c) Improve and terminal voltage will rise   (d) worsen and terminal voltage will rise 

Last Answer : In a DC shunt generator working on load, the brushes are moved forward in the direction of rotation, as a result of this, commutation will Improve but terminal voltage will fall 

Description :  If shunt generator delivers 100 A at 200 V, and the resistance of the shunt field and armature are 100 ohm and 0.01 ohm respectively, the generated e.m.f. will be : -  a) 212 V b) 205 V c) 210 V d) 201.02 V

Last Answer :  If shunt generator delivers 100 A at 200 V, and the resistance of the shunt field and armature are 100 ohm and 0.01 ohm respectively, the generated e.m.f. will be : - 201.02 V

Description :  An 8 pole lap wound DC shunt generator is supplying 295A to a load. The field current of the generator is 5A. The current per parallel path is: -  a) 300A b) 200A c) 150A d) 37.5A

Last Answer :  An 8 pole lap wound DC shunt generator is supplying 295A to a load. The field current of the generator is 5A. The current per parallel path is: - 37.5A

Last Answer : A cumulatively compounded long shunt generator when operating as a motor would be differentially compounded long shunt.

Description : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be?

Last Answer : The e.m.f. induced in the armature of a shunt generator is 600 V. The armature resistance is 0.1 ohm. If the armature current is 200 A, the terminal voltage will be 580 V.

Description : A shunt generator running at 1000 r.p.m. has generated e.m.f. as 200 V. If the speed increases to 1200 r.p.m., the generated e.m.f. will be nearly?

Last Answer : 200V/E2 = 1000/1200 E2= 240 V

Description : Hysteresis in a direct current generator is indicated by _____________. A. arcing at the brushes B. pulsating terminal current C. heating of the armature core D. hunting and over control

Last Answer : Answer: C

Description : Which of the following is FALSE ? (A) The grammar S ⟶ aSb|bSa|SS|∈, where S is the only non-terminal symbol and ∈ is the null string, is ambiguous. (B) SLR is powerful than LALR. (C) An LL(1) parser is a top-down parser. (D) YACC tool is an LALR(1) parser generator.

Last Answer : (B) SLR is powerful than LALR.

Description : The steady-state fault current during a 3 phase terminal fault on a generator is limited by: (1) Transient reactance of the generator (2) Sub-transient reactance of the generator (3) Synchronous reactance of the generator (4) DC off—set during the instant of the fault

Last Answer : 1

Description : The terminal characteristics of a dc generator suitable for electric welders is (A) separately excited generator (B) shunt generator (C) series generator (D) differentially compounded generator

Last Answer : The terminal characteristics of a dc generator suitable for electric welders is differentially compounded generator

Description : A short in the shunt field of a DC motor is best located by _____________. A. visual inspection of the commutator B. applying AC voltage to each field coil and measuring the voltage drop across ... using a growler and hacksaw blade D. isolating each coil from the others and using a megohmmeter

Last Answer : Answer: B

Description : The direction of rotation of the winch shown in the illustration is changed by reversing the _____________. EL-0102 A. direction of current through the shunt field B. polarity of voltage at 'S1' and 'S2' C. direction of current through the armature D. polarity of voltage at 'L1' and 'L2'

Last Answer : Answer: C

Description : When 220V dc shunt alternator generating the voltage at rated value. If direction of rotation is reversed, then alternator will a) Build up its voltage with same polarity b) Build up its voltage with opposite polarity c) No build up of voltage d) None

Last Answer : Ans: No build up of voltage

Description : Voltage feed back amplifier is a a) Shunt-Shunt b) Shunt-Series c) Series-Shunt d) Series- Series

Last Answer : Ans: Shunt-Shunt

Description : A shunt-type voltage regulator is connected in serial/parallel (which one) with the load resistance.

Last Answer : In parallel.

Description : A shunt type voltage regulator is connected in series/parallel with the load resistance.

Last Answer : Parallel

Description : An ammeter has a full-scale deflection current of 100mA. If the same ammeter is used to measure a full-scale current of 1.0ampere, what is the value of the shunt resistor in ohms if the voltage across the meter is 9.0 volts?

Last Answer : 10 ohms

Description : A d.c. shunt motor runs at no load speed of 1140 r.p.m. At full load, armature reaction weakens the main flux by 5% whereas the armature circuit voltage drops by 10%. The motor full load speed in r.p.m. is (A) 1080 (B) 1203 (C) 1000 (D) 1200

Last Answer : (A) 1080

Description : In order to reduce the harmful effects of harmonics on the A.C. side of a high voltage D.C. transmission system ______are provided. (A) synchronous condensers (B) shunt capacitors (C) shunt filters (D) static compensators

Last Answer : Ans: C Xc= 1/ ωc

Description : A permanent magnet moving coil instrument gives full scale deflection of 25mA when a voltage of 75mV is applied across it. Calculate: (i) Resistance of shunt required for full scale deflection of 150 A. (ii) Series resistance for full scale deflection of 500 V.

Last Answer : Answer :

Description : With the help of neat circuit diagram, explain the operation of voltage shunt type feedback amplifier.

Last Answer : Diagram:  Fig. shows common emitter transistor amplifier with a feedback resistor RF connected between its output and input terminals. This is collector to base biasing when the input signal is ... As IS = If + Ii it is shunt type therefore it voltage shunt negative feedback amplifier.

Description : An unsaturated dc shunt motor runs at its rated speed when rated voltage is applied to it. If the supply voltage to the motor is reduced by 25%, the speed of the motor  (a) Increases by 25% (b) Remains the same (c) Decreases by 25% (d) Decrease only slightly by an amount less than 25% 

Last Answer : An unsaturated dc shunt motor runs at its rated speed when rated voltage is applied to it. If the supply voltage to the motor is reduced by 25%, the speed of the motor Remains the same

Description : With 100 % inductive shunt compensation, the voltage profile is flat for?

Last Answer : With 100 % inductive shunt compensation, the voltage profile is flat for zero loading of line.

Last Answer : The mechanical power developed by a shunt motor will be maximum when the ratio of back e.m.f. to applied voltage is 0.5.

Description : How long will it take a skydiver to fall 1000 at terminal velocity?

Last Answer : Terminal velocity, if you are flat toward the ground is about180 feet per second; so time is distance/speed = 1000 feet/180 =5.5 seconds. If you roll up like a ball terminal velocity may be ashigh as 280 feet per second. and time would be about 3.5seconds.

Description : Assertion : Resistance of an ammeter is less than the resistance of a milliammeter. Reason : Value of shunt required in case of ammeter is more than a

Last Answer : Assertion : Resistance of an ammeter is less than the resistance of a milliammeter. Reason : Value of ... . If Assertion is false but Reason is true.

Description : Cathode rays in a discharge tube are made up of electrons emitted from the plate that is connected to the negative terminal of the DC voltage source.

Last Answer : Cathode rays in a discharge tube are made up of electrons emitted from the plate that is connected to the negative terminal of the DC voltage source.