Direct water cooling of rotor winding presents
(a) no mechanical difficulties
(b) lesser mechanical difficulties
(c) greater mechanical difficulties
(d) none of the above

1 Answer

Answer :

(c) greater mechanical difficulties

Related questions

Description : cooling is the process of dissipating the armature and field winding losses to a cooling medium circulating within the winding insulation wall (a) Direct (b) Indirect (c) Conventional (d) Any ofthe above

Last Answer : (a) Direct

Description : In direct cooled system using hydrogen both stator and rotor conductors are made (a) solid (b) hollow (c) perforated (d) any ofthe above

Last Answer : (b) hollow

Description : With direct water cooling it is possible to have ratings of about (a) 200 MW (b) 300 MW (c) 400 MW (d) 600 MW

Last Answer : (d) 600 MW

Description : Machines cooled by direct cooling method may be called (a) "supercharged" (b) "inner cooled" (c) "conductor cooled" (d) any of the above

Last Answer : (d) any of the above

Description : In self cooled motors the cooling time constant is about ______ than the heating time constant because cooling conditions are worse at standstill. (a) 2 to 3 times greater (b) 3 to 4 times greater (c) 4 to 5 times greater (d) none of the above

Last Answer : (a) 2 to 3 times greater

Description : The noise produced by a ______ cooled machine is less as the rotor moves in a medium of smaller density. (a) air (b) hydrogen (c) either (a) or (b) (d) none of the above

Last Answer : (b) hydrogen

Description : The high voltage winding is usually which of the following type ? (a) Cylindrical winding with circular conductors (b) Cross-over winding with either circular or small rectangular conductors (c) Continuous disc type winding with rectangular conductors (d) All of the above types

Last Answer : (d) All of the above types

Description : The winding where dummy coils are used is sometimes called (a) duplex winding (b) triplex winding (c) forced winding (d) none of the above

Last Answer : (c) forced winding

Description : The distance between the starts of two consecutive coils measured in terms of coil sides is called (a) front pitch (b) winding pitch (c) commutator pitch (d) back pitch

Last Answer : (b) winding pitch

Description : The value of exciting or magnetizing current depends upon which of the following factors ? (a) Total m.m.f. required (b) The number of turns in the exciting winding (c) The way in which the winding is distributed (d) All of the above

Last Answer : (d) All of the above

Description : A current density of _____ is ilsed for large power transformers with forced circulation of oil or with water cooling coils (a) 1.5 to 2.5 A/mm2 (b) 3.5 to 4.5 A/mm2 (c) 4.0 to 5.0 A/mm2 (d) 5.4 to 6.2 A/mm2

Last Answer : (d) 5.4 to 6.2 A/mm2

Description : Transformers with a capacity of upto _____ have a cooling radiator system with natural cooling (a) 2 MVA (b) 5 MVA (c) 7.5 MVA (d) 10 MVA

Last Answer : (d) 10 MVA

Description : The time taken by the machine to attain 0.632 of its final steady temperature rise is called (a) heating time constant (b) cooling time constant (c) either (a) or (b) (d) none of the above

Last Answer : (a) heating time constant

Description : With conventional hydrogen cooling it is possible to increase the rating of a single unit to (a) 50 MW (b) 100 MW (c) 200 MW (d) none ofthe above

Last Answer : (c) 200 MW

Description : Which ofthe following is an advantage of hydrogen cooling ? (a) Increase in efficiency (b) Increase in ratings (c) Increase in life (d) Smaller size of coolers (e) All ofthe above

Last Answer : (e) All ofthe above

Description : Multiple inlet system of air cooling of turbo-alternators can be used for machines of rating upto (a) 10 MW (b) 30 MW (c) 60 MW (d) 150 MW

Last Answer : (c) 60 MW

Description : Which ofthe following methods is used for air cooling of turbo-alternators ? (a) One sided axial ventilation (b) Two sided axial ventilation (c) Multiple inlet system (d) All ofthe above

Last Answer : (d) All ofthe above

Description : Which of the following is the basic consideration in the design of insulation ? (a) Electrical considerations (b) Mechanical considerations (c) Thermal considerations (d) All of the above

Last Answer : (d) All of the above

Description : ______is extensively used for those portions of magnetic circuit which carry steady flux and need superior mechanical properties ? (a) Grey cast-iron (b) Cast steel (c) High carbon steel (d) Stainless steel

Last Answer : (b) Cast steel

Description : The design of mechanical parts is particularly important in case of _____ speed machines. (a) low (b) medium (c) high (d) any of the above

Last Answer : (c) high

Description : In a D.C. machine the number of brush arms is _____ the number of poles. (a) less than (b) equal to (c) greater than (d) none of the above

Last Answer : (b) equal to

Description : In transformers using hot rolled steel, the cross-section of the yoke is made about _____ greater than that of the core (a) 5 percent (b) 10 percent (c) 15 percent (d) 30 percent (e) none of the above

Last Answer : (c) 15 percent

Description : The resistivity of water should not be less than (a) 10 Q m (b) 100 Q m (c) 1000 Q m (d) 2000 Q m

Last Answer : (d) 2000 Q m

Description : In D.C. machines the number of slots per pole usually lies (a) between 2 to 4 (b) between 6 to 8 (c) between 9 to 16 (d) between 20 to 30

Last Answer : (c) between 9 to 16

Description : In D.C. machines the usual limit of slot pitch is (a) between 5 to 10 mm (b) between 10 to 15 mm (c) between 15 to 20 mm (d) between 25 to 35 mm

Last Answer : (d) between 25 to 35 mm

Description : Which of the following methods may be adopted to reduce the effects of armature reaction ? (a) Increase in length of air gap at pole tips (b) Increasing reluctance of pole tips (c) Compensating windings (d) Interpoles (e) All of the above

Last Answer : (e) All of the above

Description : The operation of a D.C. machine with large air gap lengths is comparatively (a) quiet (b) noisy (c) either of the above (d) none of the above

Last Answer : (a) quiet

Description : In D.C. machines, the ____ in field mmf results in increase in size and cost of machines. (a) increase (b) decrease (c) either of the above (d) none of the above

Last Answer : (a) increase

Description : In D.C. machines, ir order to prevent excessive distortion of field form by the armature reaction, the field mmf must be made (a) equal to that of armature mmf (b) less in comparison with the arma¬ture mmf (c) large in comparison with the arma-ture mmf (d) none of the above

Last Answer : (c) large in comparison with the arma-ture mmf

Description : D.C. machines designed with a large value of air gap length have (a) worst, ventilation (b) poor ventilation (c) better ventilation (d) none of the above

Last Answer : (c) better ventilation

Description : In D.C. machines the width of the duct is usually (a) 4 mm (b) 6 mm (c) 8 mm (d) 10 mm

Last Answer : (d) 10 mm

Description : In a D.C. machine, the value of peripheral speed should not, normally, exceed (a) 10 m/s (b) 20 m/s (c) 30 m/s (d) 40 m/s

Last Answer : (c) 30 m/s

Description : In a D.C. machine the current per brush arm should not be more than (a) 100 A (6) 200 A (e) 300 A (d) 400 A

Last Answer : (d) 400 A

Description : The weight of copper of both armature and field windings decreases with _____ in number of poles. (a) increase (b) decrease (c) either of the above (d) none of the above

Last Answer : (a) increase

Description : Which of the following problem arises in D.C. motors which are fed from thyristor bridge circuits ? (a) Increased I R losses (b) Increased core losses (c) Poor commutation (d) Change in motor parameters (e) All of the above

Last Answer : (e) All of the above

Description : ________ is the common method of applying brushes to the commntator. (a) Radial (b) Trailing (c) Reaction (d) All of the above

Last Answer : (d) All of the above

Description : Which of the following brushes can be used for high values of current density ? (a) Metal graphite brushes (b) Hard carbon brushes (c) Electro-graphitic brushes (d) Natural graphite brushes

Last Answer : (a) Metal graphite brushes

Description : _____ brushes are fragile and cause excessive wear of commutator, (a) Natural graphite (b) Hard carbon (c) Electro graphitic (d) Metal graphite

Last Answer : (a) Natural graphite

Description : is usually used for brush rockers (a) Mild steel (b) Copper (c) Aluminium (d) Cast-iron

Last Answer : (d) Cast-iron

Description : The laminations of the armature of a D.C. machine are usually _____ thick. (a) 0.1 to 0.2 mm (b) 0.2 to 0.3 mm (c) 0.3 to 0.4 mm (d) 0.4 to 0.5 mm

Last Answer : (d) 0.4 to 0.5 mm

Description : The stator of a D.C. machine comprises of (a) main poles (6) interpoles (c) frame (d) all of the above

Last Answer : (d) all of the above

Description : D.C. servomotors are used in (a) purely D.C. control systems (6) purely AC. control systems (c) both D.C. and AC. control systems (d) none of the above

Last Answer : (a) purely D.C. control systems

Description : Which of the following in an application of D.C. motors? (a) Traction (b) Drives for process industry (c) Battery driven vehicles (d) Automatic control (e) All of the above

Last Answer : (e) All of the above

Description : The surge phenomenon is particularly important in case of (a) low voltage transformers (b) medium voltage transformers (c) high voltage transformers (d) any of the above

Last Answer : (c) high voltage transformers

Description : The cylindrical windings using circular conductors are used for current rating of (a) upto 20 A (b) upto 40 A (c) upto 60 A (d) upto 80 A

Last Answer : (d) upto 80 A

Description : The insulation between windings and grounded core and the insulation between the windings of the same phase is called (a) minor insulation (b) major insulation (c) either of the above (d) none of the above

Last Answer : (b) major insulation

Description : A practical formula for determining the thickness of insulation between low voltage and high voltage windings is (a) 1 + 0.2 kVmm (6) 2 + 0.5 kVmm (c) 4 + 0.7 kV mm (d) 5 + 0.9 kV mm

Last Answer : (d) 5 + 0.9 kV mm

Description : For large power transformers, self oil cooled type or air blast type which of the following values of current density may be used ? (a) 1.0 to 1.2 A/mm2 (b) 1.5 to 2.0 A/mm2 (c) 2.2 to 3.2 A/mm2 (d) 3.2 to 4.2 A/mm2

Last Answer : (c) 2.2 to 3.2 A/mm2

Description : For 275 kV transformers, using cold rolled grain oriented steel, which of the following values of flux density may be used? (a) 1.0 Wb/m2 (b) 1.1 Wb/m2 (c) 1.3 Wb/m2 (d) 1.6 Wb/m2 (e) None of the above

Last Answer : (d) 1.6 Wb/m2

Description : The usual values of maximum flux densities for distribution transformers using hot rolled silicon steel are (a) 0.5 to 0.8 Wb/m2 (b) 0.8 to 1.0 Wb/m2 (c) 1.1 to 1.35 Wb/m2 (d) 1.4 to 1.8 Wb/m2

Last Answer : (c) 1.1 to 1.35 Wb/m2