The distance between the starts of two consecutive coils measured in terms of coil
sides is called
(a) front pitch
(b) winding pitch
(c) commutator pitch
(d) back pitch

1 Answer

Answer :

(b) winding pitch

Related questions

Description : When the two coil sides forming a coil are spaced exactly one pole pitch apart they are said to be of (a) short pitch (b) full pitch (c) either of the above (d) none of the above

Last Answer : (b) full pitch

Description : The winding where dummy coils are used is sometimes called (a) duplex winding (b) triplex winding (c) forced winding (d) none of the above

Last Answer : (c) forced winding

Description : _____ brushes are fragile and cause excessive wear of commutator, (a) Natural graphite (b) Hard carbon (c) Electro graphitic (d) Metal graphite

Last Answer : (a) Natural graphite

Description : A current density of _____ is ilsed for large power transformers with forced circulation of oil or with water cooling coils (a) 1.5 to 2.5 A/mm2 (b) 3.5 to 4.5 A/mm2 (c) 4.0 to 5.0 A/mm2 (d) 5.4 to 6.2 A/mm2

Last Answer : (d) 5.4 to 6.2 A/mm2

Description : In D.C. machines the usual limit of slot pitch is (a) between 5 to 10 mm (b) between 10 to 15 mm (c) between 15 to 20 mm (d) between 25 to 35 mm

Last Answer : (d) between 25 to 35 mm

Description : The high voltage winding is usually which of the following type ? (a) Cylindrical winding with circular conductors (b) Cross-over winding with either circular or small rectangular conductors (c) Continuous disc type winding with rectangular conductors (d) All of the above types

Last Answer : (d) All of the above types

Description : The value of exciting or magnetizing current depends upon which of the following factors ? (a) Total m.m.f. required (b) The number of turns in the exciting winding (c) The way in which the winding is distributed (d) All of the above

Last Answer : (d) All of the above

Description : Direct water cooling of rotor winding presents (a) no mechanical difficulties (b) lesser mechanical difficulties (c) greater mechanical difficulties (d) none of the above

Last Answer : (c) greater mechanical difficulties

Description : cooling is the process of dissipating the armature and field winding losses to a cooling medium circulating within the winding insulation wall (a) Direct (b) Indirect (c) Conventional (d) Any ofthe above

Last Answer : (a) Direct

Description : Dummy coil should not be used in (a) small machines (b) large machines (c) either (a) or (b) (d) none of the above

Last Answer : (b) large machines

Description : The change in flux linkages can be caused in which ofthe following ways ? (a) The flux is constant with respect to time and is stationary and the coil moves through it (b) The coil is stationary with ... above occure together, i.e., the coil moves through a time varying field (d) All ofthe above

Last Answer : (d) All ofthe above

Last Answer : In case of a 4-pole D.C. generator provided with a two layer lap winding with sixteen coils, the pole pitch will be 8.

Description : Pitch of coil is defined as axial distance in compressed state of the coil. a) Yes b) It is measured in uncompressed state c) It is same in uncompressed or compressed state d) None of the listed

Last Answer : b) It is measured in uncompressed state

Description : If uncompressed length of spring is 40mm and number of coils 10mm, then pitch of coil is? a) 4 b) 40/9 c) 40/11 d) None of the mentioned

Last Answer : b) 40/9

Description : When troubleshooting motor controllers, a shorted relay or contactor coil is often indicated by _______________. A. a resistance reading of 'infinity' on an ohmmeter B. charred insulation and/or a blown ... of the coil's leads to ground D. a higher-than-normal voltage reading across the winding

Last Answer : Answer: B

Description : Three factors responsible for the change in voltage as load is applied to an AC generator are: 1) the drop in resistance in the armature circuit, 2) the change in flux, and 3) the ____________. A. armature winding speed B. inductance load drop C. coil pitch factor D. armature reactance voltage drop

Last Answer : Answer: D

Description : In which condition the axial distance between two adjacent coils is called as pitch? a. Compressed condition b. Uncompressed condition c. Both a. and b. d. None of the above

Last Answer : b. Uncompressed condition

Description : The insulation between windings and grounded core and the insulation between the windings of the same phase is called (a) minor insulation (b) major insulation (c) either of the above (d) none of the above

Last Answer : (b) major insulation

Description : The time taken by the machine to attain 0.632 of its final steady temperature rise is called (a) heating time constant (b) cooling time constant (c) either (a) or (b) (d) none of the above

Last Answer : (a) heating time constant

Description : Machines cooled by direct cooling method may be called (a) "supercharged" (b) "inner cooled" (c) "conductor cooled" (d) any of the above

Last Answer : (d) any of the above

Description : In D.C. motor construction, the armature coils' ends are _______________. A. soldered to the commutator bar risers B. imbedded into core slots C. crimped together with brush pigtails D. spliced with the field windings

Last Answer : Answer: A

Description : A generator has been exposed to water and is being checked for its safe operation. Therefore, it is necessary to _______________. A. check for shorted coils with a growler B. take moisture readings with a ... a megger D. ground the commutator, or slip rings and run it at half load for 12 hours

Last Answer : Answer: C

Last Answer : In a A.C. series motor armature coils are usually connected to commutator through resistance.

Description : Which ofthe following methods is used for air cooling of turbo-alternators ? (a) One sided axial ventilation (b) Two sided axial ventilation (c) Multiple inlet system (d) All ofthe above

Last Answer : (d) All ofthe above

Description : In D.C. machines the number of slots per pole usually lies (a) between 2 to 4 (b) between 6 to 8 (c) between 9 to 16 (d) between 20 to 30

Last Answer : (c) between 9 to 16

Description : Which of the following methods may be adopted to reduce the effects of armature reaction ? (a) Increase in length of air gap at pole tips (b) Increasing reluctance of pole tips (c) Compensating windings (d) Interpoles (e) All of the above

Last Answer : (e) All of the above

Description : The operation of a D.C. machine with large air gap lengths is comparatively (a) quiet (b) noisy (c) either of the above (d) none of the above

Last Answer : (a) quiet

Description : In D.C. machines, the ____ in field mmf results in increase in size and cost of machines. (a) increase (b) decrease (c) either of the above (d) none of the above

Last Answer : (a) increase

Description : In D.C. machines, ir order to prevent excessive distortion of field form by the armature reaction, the field mmf must be made (a) equal to that of armature mmf (b) less in comparison with the arma¬ture mmf (c) large in comparison with the arma-ture mmf (d) none of the above

Last Answer : (c) large in comparison with the arma-ture mmf

Description : D.C. machines designed with a large value of air gap length have (a) worst, ventilation (b) poor ventilation (c) better ventilation (d) none of the above

Last Answer : (c) better ventilation

Description : In D.C. machines the width of the duct is usually (a) 4 mm (b) 6 mm (c) 8 mm (d) 10 mm

Last Answer : (d) 10 mm

Description : In a D.C. machine, the value of peripheral speed should not, normally, exceed (a) 10 m/s (b) 20 m/s (c) 30 m/s (d) 40 m/s

Last Answer : (c) 30 m/s

Description : In a D.C. machine the current per brush arm should not be more than (a) 100 A (6) 200 A (e) 300 A (d) 400 A

Last Answer : (d) 400 A

Description : In a D.C. machine the number of brush arms is _____ the number of poles. (a) less than (b) equal to (c) greater than (d) none of the above

Last Answer : (b) equal to

Description : The weight of copper of both armature and field windings decreases with _____ in number of poles. (a) increase (b) decrease (c) either of the above (d) none of the above

Last Answer : (a) increase

Description : Which of the following problem arises in D.C. motors which are fed from thyristor bridge circuits ? (a) Increased I R losses (b) Increased core losses (c) Poor commutation (d) Change in motor parameters (e) All of the above

Last Answer : (e) All of the above

Description : ________ is the common method of applying brushes to the commntator. (a) Radial (b) Trailing (c) Reaction (d) All of the above

Last Answer : (d) All of the above

Description : Which of the following brushes can be used for high values of current density ? (a) Metal graphite brushes (b) Hard carbon brushes (c) Electro-graphitic brushes (d) Natural graphite brushes

Last Answer : (a) Metal graphite brushes

Description : is usually used for brush rockers (a) Mild steel (b) Copper (c) Aluminium (d) Cast-iron

Last Answer : (d) Cast-iron

Description : The laminations of the armature of a D.C. machine are usually _____ thick. (a) 0.1 to 0.2 mm (b) 0.2 to 0.3 mm (c) 0.3 to 0.4 mm (d) 0.4 to 0.5 mm

Last Answer : (d) 0.4 to 0.5 mm

Description : The stator of a D.C. machine comprises of (a) main poles (6) interpoles (c) frame (d) all of the above

Last Answer : (d) all of the above

Description : D.C. servomotors are used in (a) purely D.C. control systems (6) purely AC. control systems (c) both D.C. and AC. control systems (d) none of the above

Last Answer : (a) purely D.C. control systems

Description : Which of the following in an application of D.C. motors? (a) Traction (b) Drives for process industry (c) Battery driven vehicles (d) Automatic control (e) All of the above

Last Answer : (e) All of the above

Description : The surge phenomenon is particularly important in case of (a) low voltage transformers (b) medium voltage transformers (c) high voltage transformers (d) any of the above

Last Answer : (c) high voltage transformers

Description : The cylindrical windings using circular conductors are used for current rating of (a) upto 20 A (b) upto 40 A (c) upto 60 A (d) upto 80 A

Last Answer : (d) upto 80 A

Description : A practical formula for determining the thickness of insulation between low voltage and high voltage windings is (a) 1 + 0.2 kVmm (6) 2 + 0.5 kVmm (c) 4 + 0.7 kV mm (d) 5 + 0.9 kV mm

Last Answer : (d) 5 + 0.9 kV mm

Description : Which of the following is the basic consideration in the design of insulation ? (a) Electrical considerations (b) Mechanical considerations (c) Thermal considerations (d) All of the above

Last Answer : (d) All of the above

Description : For large power transformers, self oil cooled type or air blast type which of the following values of current density may be used ? (a) 1.0 to 1.2 A/mm2 (b) 1.5 to 2.0 A/mm2 (c) 2.2 to 3.2 A/mm2 (d) 3.2 to 4.2 A/mm2

Last Answer : (c) 2.2 to 3.2 A/mm2

Description : For 275 kV transformers, using cold rolled grain oriented steel, which of the following values of flux density may be used? (a) 1.0 Wb/m2 (b) 1.1 Wb/m2 (c) 1.3 Wb/m2 (d) 1.6 Wb/m2 (e) None of the above

Last Answer : (d) 1.6 Wb/m2

Description : The usual values of maximum flux densities for distribution transformers using hot rolled silicon steel are (a) 0.5 to 0.8 Wb/m2 (b) 0.8 to 1.0 Wb/m2 (c) 1.1 to 1.35 Wb/m2 (d) 1.4 to 1.8 Wb/m2

Last Answer : (c) 1.1 to 1.35 Wb/m2