Write the formula from Star to Delta ?

1 Answer

Answer :

Answer : Dividing the product of the resistors connected to the star by dividing the resistors of the opposite arm by taking two together, the quotient is equal to the value of each resistor connected.

Related questions

Description : What is Delta Connection ?

Last Answer : When three resistors are connected in such a way that a closed loop is formed by connecting the first end of one resistor to the second end of the other resistor and a line or lead is drawn from each connection point then it is called delta connection.

Description : Write the limitations of Kelvin's formula ?

Last Answer : As sometimes the cross section of the wire is so low that the regulation increases as the voltage drop increases . Increases , interest and waste change as space and time change.

Description : Write Kelvin's formula ?

Last Answer : In the case of energy transport , the cross-section of the lowest cost line conductor will occur only when the annual waste and interest cost is equal to the annual waste cost .

Description : Write the formula for inductive reaction ?

Last Answer : Formula for inductive reactance: XL = 2τƒL . It depends on the frequency and inductance of the coil. Since the inductance of a coil is constant, its inductive reactance changes at a rate proportional to the change in frequency.

Description : Draw the star and delta connection. State any one conversion formula.

Last Answer : star and delta connection

Description : What is Star Connection ?

Last Answer : When three ends of three resistors are connected to a point and the other three ends are taken out to connect three lines or leads, it is called a star connection.

Description : Transformer is based on which formula ?

Last Answer : It is based on Faraday's formula. Now the question may arise that Mr. Faraday said that in order to occupy a magnetic field with another coil, one of them must move. Tachara flux will not be obsessed ... DC. So it does not have to be shaken separately. Because its waves tend to be self-evident.

Description : What is the formula of lens ?

Last Answer : The direction of the electric current induced by the electromagnetic induction will be such that the flow will always interfere with the cause of the current.

Description : What is the formula for synchronous speed ?

Last Answer : Synchronous speed formula Ns = 120f / p

Description : What is Lenz's formula ?

Last Answer : The induced current flowing through the conductive wire due to the induced electromagnetic ball creates a magnetic field around the conductor wire , which prevents the origin of the induced current through it (i.e. the changing magnetic field).

Description : When does the formula of resistance apply ?

Last Answer : When it is necessary to know the resistance of a conductor, the resistance formula is required.

Description : What is the formula for determining the power in a circuit ?

Last Answer : The formula for circuit power is P = V * I watt here , P is power V is voltage I is current.

Description : What is the formula for diagnosing voltage deficiency ?

Last Answer : The formula for determining voltage deficit is V = IR

Description : What is the formula for determining the efficiency of generator ?

Last Answer : Generator efficiency = (effective power * 100) / given power

Description : What is the formula for motor efficiency ?

Last Answer : Motor efficiency = (output / input) 100

Description : What is Ohm's voltage formula ?

Last Answer : : Current flowing through a conductor at a constant temperature is proportional to the voltage across the two ends of the conductor. Or the current flowing through a conductor at a constant ... to the voltage difference between the two ends of that conductor and disproportionate to the resistance.

Description : Write different font names or different short circuit font names ?

Last Answer : There are two main types of short circuit faults. Namely- 1. Semantic faults and 2. Asymmetrical font Symmetrical fault - a) Short circuit three phases together b) Short circuit asymmetrical fault with three ... result c) Double line to ground font d) Two phase one Circuit and third phase earth.

Description : Write the maximum power transfer theorem ?

Last Answer : The maximum power transfer from a DC source to a resistive load will occur only when the internal resistance is equal to the series resistance connected to the load resistance source .

Description : Write the Thebin Theorem ?

Last Answer : The current of a load resistance connected to two points of a complex network consisting of multiple sources of EMF and resistance will be the same if the load is connected to a single fixed source of EMF .

Description : Write the types of modulation and demodulation ?

Last Answer : There are three main types of modulation. Namely: (a) Amplitude modulation: The modulation in which the amplitude of the carrier signal changes according to the modulating frequency is called ... the carrier signal changes according to the modulating frequency is called phase modulation.

Description : Write the use of diode ?

Last Answer : : Use of diode The use of diode is given below: (a) Acts as rectifier. (B) Acts as a dimulator or detector. (C) Acts as a switch. (D) Used in wave shaping circuits.

Description : Write the use of ginner diode ?

Last Answer : : Ginner diodes are used in the following places: (a) for DC voltage stabilizer and regulation. (B) To limit the amplitude of AC voltage. (C) Analog circuits. (D) Used in power circuits and ... diode is used in clippers circuit. (G) Ginner diodes are used in clipper clamper and protector circuits.

Description : Write the use of LED ?

Last Answer : The use of LEDs is highlighted below: (a) For digital display on decaed instruments. (B) In digital watch. (C) On the computer. (D) In all the techniques in which invisible light is used. ... in image sensing circuit. (G) LED is used in silica fiber optical cable in optical communication circuit .

Description : Write the properties of LED ?

Last Answer : LED features ( i) Fast on-off switching. ( ii) It is longevity. ( iii) Voltage consumption is low. ( iv) Gallium arsenide is used to obtain infrared algae.

Description : Write using photo diode ?

Last Answer : : Use of photo diode (a) to operate the relay circuit , ( b) to read the punch card of the computer fast , ( c) to automatically control the angle system , ( d) to determine the number ... , ( F) are used for controlling photoelectric resistors , ( g) are used for voltage and heat control systems.

Description : Write the properties of photo diode ?

Last Answer : : Features of photo diode ( i) It works based on Ala. ( ii) When the temperature is high, the resistance decreases , resulting in more current flowing. ( iii) When the light is low, the resistance increases , so the current flows less.

Description : Write the use of UPS ?

Last Answer : UPS is used to provide uninterrupted power supply to computer , medical equipment, and electrical devices, and to protect the device from voltage regulation , overvoltage , and undervoltage .

Description : Write speaker usage ?

Last Answer : The speaker is used in the following cases. Namely: (a) Used to convert amplified electrical energy into human audible sound energy. (B) For the production of sound waves in radio and ... sound in public address system , tape recorder , computer amplifier. (D) Used in telecommunication equipment.

Description : What equipment are star delta starters used in?

Last Answer : Star Delta starter is used to start the AC motors with rating generally higher than 11 kw, depending upon the type of load.

Description : If P is the power of a star connected system then what will be power of an equivalent delta connected system? A..P B. 3P C. P/3 D. None of the above

Last Answer : Ans: A

Description : Disadvantages of Star-Delta Starting of Induction motor?

Last Answer : In Star-Delta starting induction motor stator is connected in star connection for starting after picking up speed it is connected to delta connection. When induction motor is connected in star connection ... . This also results in reduced starting torque (1/3 times compared to delta connection).

Description : What advantage has the star connection over the delta connection ?

Last Answer : A. Each star connection transformer is wound for only 57.7% of line voltage . In hv transmission, this admits of much smaller transformer being built for high voltage than possible with delta connection, because of less insulation.

Description : Why Delta Star Transformers are used for Lighting Loads?

Last Answer : A. For lighting loads, neutral conductor is must and hence the secondary must be star winding.This lighting load is always unbalanced in all three phases. To minimize the current unbalance in the primary we use delta winding in the primary. So delta / star transformer is used for lighting loads.

Description : What is the difference between delta-delta, delta-star transformer?

Last Answer : A. Delta-delta transformer is used at generating station or a receiving station for Change of Voltage (i,e) generally it is used where the Voltage is high & Current is low whereas Delta-star ... star neutral is taken as a return path and this configuration is used for Step down voltage phenomena.

Description : Why Delta Star transformer Are Used For Lighting Loads?

Last Answer : For lighting loads, neutral conductor is must and hence the secondary must be star winding. and this lighting load is always unbalanced in all three phases. To minimize the current unbalance in the primary we use delta winding in the primary. So delta / star trformer is used for lighting loads.

Description : Why input transformer of PUPS module 1 is delta-delta and module 2 is delta-star?

Last Answer : With the help of this arrangement, combined DC output from both chargers is equivalent to that from a 12-pulse rectifier. Advantage of 12-pulse rectifier is that the mains current is fairly close ... phase angle difference 30-degree between module 1 output and module 2 output give 12-pulse output. 

Description : Why delta – delta CT’s are used for star – star transformer differential protection?

Last Answer : Say primary neutral is not solidly earthed. Then for any earthfault on secondary terminal, the primary current distribution is so for external fault, the differential is likely to operate if sequence current ... into relay. The 2:1:1 distribution is possibly only for core type or delta tertiary.

Description : State the voltage and current relation in star and delta connection. 

Last Answer : In star connection line current is equal to the phase current and line voltage is √3 times that of phase voltage. In delta connection line voltage is equal to the phase voltage and line current is √3 times that of phase current. 

Description : What are the value of voltage and current in star connection and in delta connection?

Last Answer : Star connection a. IL = IPh. b. VL = √3 VPh. ∴ VPh = VL/√3. Note: in star connection we are getting neutral point and we can able to measure the phase as well as line voltage. Delta connection a. VL = VPh. b. IL = √3 IPh. ∴ IPh = IL/√3.

Description : What are the advantages of star-delta starter with induction motor?

Last Answer : The main advantage of using the star delta starter is reduction of current during the starting of the motor. Starting current is reduced to 3-4 times of current of Direct online starting Hence the starting current is reduced , the voltage drops during the starting of motor in systems are reduced

Description : Why Delta Star Transformers are used for Lighting Loads?

Last Answer : For lighting loads, neutral conductor is must and hence the secondary must be star winding and this lighting load is always unbalanced in all three phases.  To minimize the current unbalance in the primary we use delta winding in the primary So delta / star transformer is used for lighting loads.

Description : Why star delta starter is preferred with induction motor?

Last Answer : Star delta starter is preferred with induction motor due to following reasons: Starting current is reduced 3-4 times of the direct current due to which voltage drops and hence it causes less ... caused. In addition, starting torque is increased and it prevents the damage of motor winding.

Description : What is star / delta ?*

Last Answer : In star VL = √3 VΦ In delta VL = VΦ

Description : Is the alternator connected star or delta

Last Answer : Look up in Dennis T Hall. Also in your ship ask E/O. Normally star.

Description : If a motor is wound star and you want to change to delta what should you do?

Last Answer : Open the terminal connection box. Remove the shorting link connecting the common connection (star) point of A2, B2 and C2. With the 3 phase windings marked A1A2, B1B2, C1C2, connect A2 to B1, B2 to C1 and C2 to A1.

Description : Is the ship's alternator Star wound or Delta wound?

Last Answer : Refer Dennis T Hall

Description : What is the meaning of Star winding/ Delta winding?

Last Answer : Refer Dennis T Hall

Description : In a three phase transformer, if the primary side is connected in star and secondary side is connected in delta, what is the angle difference between phase voltage in the two cases. (A) delta side lags by -30°. (B) star side lags by -30°. (C) delta side leads by 30°. (D) star side leads by -30°.

Last Answer : Ans: C This is vector group and has +30° displacement. Therefore, delta side leads by +30°.

Description : Convert the delta network into equivalent star network.

Last Answer : Delta to start network R1 = 4x6/ 4+6+2 = 24/12 =2/1= 2Ω R2 = 2x6/ 4+6+2 = 12/12= 1 = 1Ω R3 = 4x 2/ 4+6+2 = 8/12= 2/3= 0.66Ω

Description : Derive an expression for delta to star transformation. 

Last Answer : For delta network the resistance between the terminals 1 and 2 consists of R12 in parallel with  (R23+R31) Hence ,the resistance between the terminals 1 and 2 is In case of star network the ... equation( ii) from( i),we get Adding equations (iii) and( iv),we have