Copper shading is provided in energy meter to 

(A) Bring flux exactly in quadrature with applied voltage (B) To increase speed of aluminium disc (C) To count the rotation (D) To balance the system from vibration 

1 Answer

Answer :

A

Related questions

Last Answer : The adjustment of position of shading bands, in an energy meter is done to provide friction compensation.

Description : Why shading rings provided in armature core of ac contactor. Why not for dc contactor? 

Last Answer : Because the force developed is not steady in ac therefore contacts will chatter but if shading ring is used force developed becomes steady due to splitting of phases of flux, therefore contacts becomes bounce free and humming sound reduces.  

Description : How does an artist address a subjects fixed color with its appearance in a world of shading and perspective?

Last Answer : Yes, very much so. I know that it has been recommended that if you are going to work from a photograph, not to use flash photography when you are first learning. Flash photography destroys a lot of ... really there. Taking a flat image and giving it depth, that is what creative license is all about.

Description : Are you an artist? if so, how do you apply shading to your drawing, painting, sculptures, ect.?

Last Answer : I don't do cross hatching much, but I know the more crosses/lines you do, the darker that area will look, and the more spaced out they are, the lighter it will look. For painting, I found it was ... you know where to shade, or at least picture where the light source would be if you don't have one.

Last Answer : any Specific Area Of electricity Demand Production Or Supply In comparison More If Then Electricity Subcenter In favor of Demand To meet Possible Is No. Then Subcenter Authority Something Specific In ... Or Something Of time For Electricity Connection Isolated By Gives This one Load Shading Says.

Description : If you were drawing a map of your state what colar shading might you use?

Last Answer : red green

Description : What is a map that uses shading to show elevations called?

Last Answer : It is a shaded relief map.

Description : Excessive humming of AC contactors may be caused by ______________. A. burnt arc shields B. shorted armature coils C. a broken shading coil D. high voltage

Last Answer : Answer: C

Description : A loud buzzing noise in an AC controller is probably caused by _____________. A. poor contact with the overload relay B. an incorrectly sized heater C. a broken shading coil D. abnormal starting current

Last Answer : Answer: C

Description : If the contacts of a motor starter or controller fail to drop out when the 'stop' button is depressed the ____________. A. contacts are carrying excessive current B. contacts have become welded together C. shading coil is broken D. shading coil is loose

Last Answer : Answer: B

Description : Shading coils are installed on AC full-voltage starters to _____________. A. eliminate contact chatter B. dissipate opening contact arcs C. delay current build up in the holding coil D. protect the motor windings from momentary starting current overload

Last Answer : Answer: A

Description : A shading coil used in an AC magnetic controller, functions to _____________. A. reduce vibration and noise in the contactor B. prevent flux buildup in the operating coil C. eliminate arcing when the contacts close D. energize the operating coil and 'pull in' the contacts

Last Answer : Answer: A

Description : A molded-case circuit breaker provides protection against short circuits by using a/an ________________. A. electromagnet B. shading coil C. arc quencher D. burn away strip

Last Answer : Answer: A

Description : A molded-case breaker provides protection against short circuits by using a/an ____________. A. shading coil B. arc quencher C. electromagnet D. holding coil

Last Answer : Answer: C

Description : What is the use of shading ring in a pole motor?

Last Answer : The shading coil causes the flux in the shaded portion to lag behind the flux in unshaded portion of pole. This gives in effect a rotation of flux across the pole face and under the influence of this moving flux a staRting torque is developed.

Description : To change the font size in order to display more text or other data A. Border B. Shading C. Shrink to fit D. Printing area

Last Answer : A. Border

Last Answer : In a shaded pole motor, the shading coil usually consist of a single turn of heavy copper wire which is short-circuited and carries only induced current.

Description : A switchboard, for a AC electrical distribution system, will be provided with which of the following components? A. Frequency meter. B. Ammeter C. Voltmeter D. All of the above

Last Answer : Answer: D

Description : The working of a meter is based on the use of a permanent magnet. In order to protect the meter functioning from stray magnetic fields (a) meter is surrounded by strong magnetic fields (b) a soft ... is used (c) a plastic shielding is provided (d) a shielding of anon-magnetic material is used

Last Answer : (b) a soft iron shielding is used

Description : Indication post for detonator should be provided at a distance of ---------meter and --------- meter for BG level crossing a) 400 meters in 800 meters b) 500 meters and 1200 meters c) 600 meters and 1200 meter * d)600 meters and 1000 meters

Last Answer : c) 600 meters and 1200 meter *

Last Answer : In a dynamo-meter type of moving coil instrument a swamping resistance is provided inorder to: Provide equal time constant for moving coil and fixed coil, when used for ac measurement

Description : Why bimetallic washers provided in aluminium copper transition joints?

Last Answer : To avoid galvanic corrosion failure.  

Description : Service connections to consumers houses, are generally provided with (A) Copper pipes (B) Hume pipes (C) Galvanised iron pipes (D) P.V.C. pipe

Last Answer : (C) Galvanised iron pipes

Description : Draw a block diagram of electronic energy meter. Write function of each block.

Last Answer : Electronic Energymeter  Functions of components/blocks: - CT reduces current to reasonable value for current scaling network. - Voltage & current scaling networks reduce proportionally the voltage ... ADC converts the square wave frequency analog output to display the energy in watthour.

Description : State the function and shape of following parts used in induction type energy meter: i) Series magnet ii) Shunt magnet iii) Al disc iv) Brake magnet

Last Answer : i) Series magnet: produce flux proportional to current (load current) of circuit and interact in the aluminum disc with flux produced by voltage magnet for torque production. Its shape is like letter U.  ii) ... : brakes the motion of the aluminum disc or slows it down. Its shape is like letter C. 

Description : State the meaning of creeping error in 1 phase energy meter.

Last Answer : Creeping error: It is defined as the slow and continuous rotation of the disc of the energy-meter when only pressure coil is energized with no current in the current coil (load current = 0). ... magnet on this iron wire is sufficient to prevent continues rotation of the disc on no load condition.

Description : Draw a neat sketch of 1-ph induction type energy meter and write operating principle of it. 

Last Answer : Operating Principal:- The disc is placed between the two-flux due to pressure coil and flux due to current coil, which will set up torque on the disc which is proportional to power causing the ... is proportional to voltage, the second carries a current coil so its flux is proportional to current.

Description : Draw and describe working of electronic energy meter.

Last Answer : working of electronic energy meter:- 1. CT reduces current to reasonable value for current scaling network. 2. Voltage & current scaling networks reduce proportionally the voltage & ... The ADC converts the square wave frequency analog output to display the energy in watthour. 

Description : What is meant by energy meter constant?

Last Answer : Energy Meter Constant  A fixed value which is used when converting meter readings to actual energy use, especially when potential transformers and similar types of equipment are used in metering. For example, K=--------rev/Kwh

Description : With neat diagram explain calibration of energy meter by direct loading method.

Last Answer : Calibration of Energy Meter by Direct Loading Method:  There are three methods for testing/calibration:  1. Long period dial test  2. Using rotary sub- standard meter  3. Using precision grade instruments  All ... of substandard meter in kWh  Then % error = [(D - DS)/DS] x 100

Description : Why energy meter is integrating type measuring instrument?

Last Answer : Energy Meter is Integrating Type Measuring Instrument: Energy meter is used for measurement of energy, which is obtained by integration (summation) of power supplied over the particular time duration, hence it the integrating type measuring instrument. 

Description : Write any two advantages of digital energy meter.

Last Answer : Advantages of Digital Energy Meter: 1) Easy to read. 2) High accuracy 3) High resolution. 4) No frictional losses as there are no moving parts. 5) No requirement for external adjustments. 6) Large ... due to absence of moving parts. 7) Highly efficient. 8) Very much compact. 9) Good reliability.

Description : List any four errors in induction type energy meter. Give method of compensation for each.

Last Answer : Errors in Induction Type Energy Meter with their Compensation:  1) Error due to friction: This error can be compensated by the additional shading band provided on the shunt electromagnet.  2) Phase ... error: This error can be compensated by providing a flux diverter' to the current magnet. 

Description : For controlling the vibration of the disc of ac energy meter, damping torque is produced by

Last Answer : For controlling the vibration of the disc of ac energy meter, damping torque is produced by Eddy current

Description : The current coil of a single-phase energy meter is wound on (a) One limb of the laminated core (b) Both the limbs of the laminated core with same number of turns (c) Both the limbs of the laminated core with different number of turns (d) The centre of the limb on the laminated core

Last Answer : The current coil of a single-phase energy meter is wound on Both the limbs of the laminated core with same number of turns

Description : One single-phase energy meter operating on 230 V and 5 A for 5 hours makes 1940 revolutions. Meter constant is 400 rev/kWh. The power factor of the load is

Last Answer : One single-phase energy meter operating on 230 V and 5 A for 5 hours makes 1940 revolutions. Meter constant is 400 rev/kWh. The power factor of the load is 0.8

Description : In an induction type energy meter, the steady speed attained by the rotating disc is  1. Proportional to the deflecting torque. 2. Proportional to the resistance of the path of eddy currents. 3. ... 4. Inversely proportional to the square of brake magnet flux.  Which of the above are correct ?

Last Answer : In an induction type energy meter, the steady speed attained by the rotating disc is 1. Proportional to the deflecting torque. 2. Proportional to the resistance of the path of eddy currents. 3. Inversely proportional to ... brake magnet flux. Which of the above are correct ? 1, 2, 3 and 4 

Description : A single phase energy meter has a constant of 1200 revolution/kWh. When a load of 200 W is connected, the disc rotates at 4.2 revolutions per min. If the load is on for 10 hours, the meter records an excess of   (a) 0.1 kWh (b) 0.2 kWh (c) 1.0 kWh (d) 2.0 kWh 

Last Answer : 2

Description : The major cause for creeping in energy—meter is:  (1) Over compensation for friction (2) Vibrations (3) Stray magnetic fields (4) Excessive voltage across the potential coil

Last Answer : The major cause for creeping in energy—meter is: Over compensation for friction.

Description : An energy meter has a constant of 600 rev/kWh. If the meter makes 10 revolutions in 20 s, what is the load in kW?  (A) 0.75 kW (B) 1.5 kW (C) 3 kW (D) 6 kW 

Last Answer : 1.5 kW 

Last Answer : The series magnet of a single phase Energy meter consists of coil of thick wire of few turns.