In wound rotor alternator, reactive power is maximum at a load angle of 

1 Answer

Answer :

In wound rotor alternator, reactive power is maximum at a load angle of 0o

Related questions

Description : A alternator is delivering power to a balanced load at unit power factor. The phase angle between the line voltage and the line current is? (A) 90° (B) 60° (C) 30° (D) 0° 

Last Answer : A alternator is delivering power to a balanced load at unit power factor. The phase angle between the line voltage and the line current is 30°

Description : The speed of a wound-rotor induction motor _____________. A. will be fixed by the number of field poles B. can be varied by a rheostat-type control C. can only be synchronous speed at full load D. can only attain synchronous speed at no load

Last Answer : Answer: B

Description : For a 210 MW, turbo-alternator in a thermal power plant, the possible specifications of rotor diameter, stator core length, and number of poles, respectively, are (A) 4.4 m, 1.2 m, 12 (B) 1.2 m, 4.4 m, 2 (C) 4.4 m, 1.2 m, 24 (D) 1.2 m, 4.4 m, 8

Last Answer : For a 210 MW, turbo-alternator in a thermal power plant, the possible specifications of rotor diameter, stator core length, and number of poles, respectively, are 1.2 m, 4.4 m, 2

Description : A 6 pole 3-phase wound-rotor induction machine is driven by another machine at 1800 rpm. The rotor of the induction machine is connected to a 50Hz system. If the mechanical rotation of the rotor is in the same direction as the rotor winding flux rotation, then frequency of the stator voltage will be

Last Answer : A 6 pole 3-phase wound-rotor induction machine is driven by another machine at 1800 rpm. The rotor of the induction machine is connected to a 50Hz system. If the mechanical rotation of ... the same direction as the rotor winding flux rotation, then frequency of the stator voltage will be 140 Hz.

Description : In power system, if a voltage controlled bus is treated as a load bus then which one of the following limits would be violated? a) Voltage b) Active power c) reactive power d) Phase angle

Last Answer : a) Voltage

Description : In load flow studies of a power system, a voltage control bus is specified by a) Real power and reactive power b) Reactive power and voltage magnitude c) Voltage and voltage phase angle d) Real power and voltage magnitude

Last Answer : d) Real power and voltage magnitude

Description : Which of the following types of motors is often designed for use in correcting power factor? A. Polyphase B. Wound-rotor C. Induction D. Synchronous

Last Answer : Answer: D

Description : A motor which can conveniently be operated at lagging as well as leading power factors is the (A) squirrel cage induction motor. (B) wound rotor induction motor. (C) synchronous motor. (D) DC shunt motor.

Last Answer : (C) synchronous motor.

Description : The reactive power drawn by a motor from an AC generator is the power which is _____________. A. used to establish the magnetic field of the motor B. lost in overcoming friction in the ... by current flow through the windings D. transmitted directly through the rotor shaft to perform useful work

Last Answer : Answer: A

Description : Is the ship's alternator Star wound or Delta wound?

Last Answer : Refer Dennis T Hall

Description : What is meant by load angle of an Alternator?

Last Answer : The phase angle introduced between the induced emf phasor, E and terminal voltage phasor , U during the load condition of an Alternator is called load angle.

Description : In the illustration, the assembly labeled 2 is a ________. EL-0001 A. wound rotor and shaft for a single phase induction motor B. conduction rotor and shaft for a polyphase induction motor C. ... cage rotor and shaft for a polyphase motor D. squirrel cage rotor for a single phase induction motor

Last Answer : Answer: C

Description : In D.C. motor construction, commutating windings are wound on _________________. A. opposite main poles B. interpoles C. adjacent main poles D. the rotor core

Last Answer : Answer: B

Description : In the construction of D.C. motors, parts of both the series and shunt fields are wound on the _____________. A. opposite main pole B. rotor core C. interpole D. same main pole

Last Answer : Answer: D

Description : A characteristic of a wound-rotor induction motor, with a high resistance rotor winding, is _____________. A. low starting torque B. high starting torque C. high speed D. low starting voltage

Last Answer : Answer: B

Description : Reversing any two of the three rotor leads on a wound-rotor induction motor will _____________. A. increase motor performance B. decrease motor performance C. reverse the motor rotation D. have no effect on the direction of rotation or motor performance

Last Answer : Answer: D

Description : A single-phase induction motor having a relatively high starting torque, is the ___________. A. shaded pole motor B. wound-rotor motor C. capacitor-start motor D. resistance-start motor

Last Answer : Answer: C

Description : What type of rotor is used in split-phase motors? A. Drum B. Salient pole C. Squirrel-cage D. Wound-rotor

Last Answer : Answer: C

Description : Which of the following physical characteristics does a wound-rotor induction motor possess that a squirrel cage motor does not? A. Slip rings B. End rings C. A centrifugal switch D. End plates

Last Answer : Answer: A

Description : The variable resistance placed in the rotor circuit of a wound-rotor induction motor provides for __________. A. speed control B. frequency control C. voltage control D. use as a split-phase motor

Last Answer : Answer: A

Description : A motor using a rheostat in the motor circuit to vary the speed is called a ____________. A. squirrel-cage induction motor B. regenerative braking motor C. wound-rotor induction motor D. synchronous motor

Last Answer : Answer: C

Description : Methods to control speed of Wound Rotor Motors?

Last Answer : The speed of wound rotor motors are changed by changing the slip of the motor. This can be achieved by: Varying the stator line voltage Varying the resistance in the rotor circuit Inserting and varying a foreign voltage source in the rotor circuit

Description : Why wound rotor construction is adopted?

Last Answer : The wound rotor has the facility of increasing the rotor resistance through slip rings. High value of rotor resistance is needed during starting to get a high value of starting torque.

Description : Where is a rotor wound AC motor used?

Last Answer : For starting heavy torques, mostly used on portable machines and small winches.

Description : An 8 pole wound rotor induction motor operating on 60 Hz supply is driven at 1800 r.p.m. by a prime mover in the opposite direction of revolving magnetic field. The frequency of the rotor current is (a) 30 Hz (b) 60 Hz (c) 120 Hz (d) 180 Hz 

Last Answer : 30 Hz As the frequency of the rotor is given by  F= N*P/120 so from the above equation the frequency of the rotor current can be easily calculated  i.e. 1800×8/120=30 Hence the required value of rotor frequency is 30 Hz

Description : Which of the following problems will occur if the circuit breaker of the incoming alternator is closed and it is 180° out of phase with the loaded alternator when paralleling? A. The rotor of the ... The rotor of the incoming alternator will stop. D. Both alternators will parallel 180° out of phase.

Last Answer : Answer: B

Description : Loss of or weak residual magnetism in an alternator or generator can be corrected for by _________________. A. running the rotor in the opposite direction for 5 minutes B. allowing the generator ... rheostat fully counterclockwise D. using a storage battery or battery charger to 'flash' the field

Last Answer : Answer: D

Description : The frequency output of an operating alternator is controlled by the _____________. A. relative speed of the rotor poles B. number of turns of wire in the armature coil C. strength of the magnets used D. output voltage

Last Answer : Answer: A

Description : Why alternator rotor is made of solid iron?  

Last Answer : Because, rotor flux = DC continuous No iron loss problems. 

Description : The full load torque of an electric motor is the __________. A. minimum torque developed by the motor accelerating from stop to full speed B. turning moment exerted by the motor at rated load ... and frequency D. turning moment exerted by the motor from any rotor angular position at any load

Last Answer : Answer: B

Description : A permanent magnet stepper motor with 8 poles in stator and 6 poles in rotor will have a step angle of (a) 7.5° (b) 15° (c) 30° (d) 60°

Last Answer : d

Description :  An 8 pole lap wound DC shunt generator is supplying 295A to a load. The field current of the generator is 5A. The current per parallel path is: -  a) 300A b) 200A c) 150A d) 37.5A

Last Answer :  An 8 pole lap wound DC shunt generator is supplying 295A to a load. The field current of the generator is 5A. The current per parallel path is: - 37.5A

Description : In a 3 -phase alternator, if there is only magnetizing armature reaction, the load is :  (A) capacitive (B) inductive (C) resistive (D) inductive and resistive

Last Answer : In a 3 -phase alternator, if there is only magnetizing armature reaction, the load is : capacitive 

Description : The current from the stator of an alternator is taken out to the external load circuit through: (A) slip rings (B) commutator segments (C) solid connections (D) carbon brushes

Last Answer : D  is correct

Description : The voltage of a particular bus can be controlled by controlling the a) Active power of the bus b) Reactive power of the bus c) Phase angle d) All of the above

Last Answer : b) Reactive power of the bus

Description : Which of the following statements are true? i) reactive current is necessary to build up the flux for the magnetic field of inductive devices ii) some portion of reactive current is converted into work iii) the cosine of angle ... called power factor a) i & iv b) ii & iii c) i & iii d) iii & iv

Last Answer : a) i & iv

Description : If the excitation of an alternator operating in parallel is decreased below normal, its _____________. A. power factor will change in the lagging direction B. power factor will change in the leading direction C. ampere load will be greatly increased D. kilowatt load will be greatly decreased

Last Answer : Answer: B

Description : An alternator operating in parallel begins to vibrate severely and eventually trips out on the reverse power relay. The cause of the vibration was a result of ______________________. A. the ... C. the alternator was operating out of synchronism D. flashover at the alternator collector rings

Last Answer : Answer: C

Description : A three-phase alternator is operating at 450 volts, 250 amps at 0.6 power factor. If the power factor increases to 0.8, the kw load potential will increase by _____________. A. 38.525 kw B. 116.91 kw C. 155.88 kw D. 194.85 kw

Last Answer : Answer: A

Description : To remove an alternator operating in parallel with another unit from the main electrical bus, you must FIRST _________. A. adjust the power factor on both units B. set the desired voltage on ... C. open the circuit breaker on the outgoing alternator D. remove the load from the outgoing alternator

Last Answer : Answer: D

Description : Why is it a good practice to have the frequency of the incoming alternator adjusted slightly higher than that of the loaded alternator when paralleling two alternators? A. This allows the oncoming machine to ... line. C. The reverse power relay is prevented from activating. D. All of the above.

Last Answer : Answer: D

Description : In the illustration, if one of the devices labeled 'TURB' should fail the ___________. EL-0003 A. device labeled 'EXC' will drive the alternator B. device labeled 'BKR' for that ... -alternator D. emergency generator should automatically start and be placed on line to supply emergency load centers

Last Answer : Answer: B

Description : What is the power factor of an alternator at no load?

Last Answer : Answer:At no load Synchronous Impedance of the alternator is responsible for creating angle difference. So it should be zero lagging like inductor.

Description :  An 8-pole alternator runs at 750 rpm and supplies power to a 6-pole induction motor which has a full load slip of 3 percent. The full load speed of the induction motor will be: A) 1000 rpm B) 920 rpm C) 950 rpm D) 970 rpm

Last Answer : An 8-pole alternator runs at 750 rpm and supplies power to a 6-pole induction motor which has a full load slip of 3 percent. The full load speed of the induction motor will be: 970 rpm

Description : What will be the reactive power and bus voltage whan the generator bus is treated as load bus.

Last Answer : When the generator bus is treated as load bus, the reactive power of the bus is equated to the limit it has violated, and the previous iteration value of bus voltage is used for calculating current iteration value.

Description : In a load flow analysis of a power system, the load connected at a bus is represented as a) Constant current drawn from the bus b) Constant impedance connected at the bus c) Voltage and frequency dependent sources at the boss d) Constant real and reactive power drawn from the bus

Last Answer : d) Constant real and reactive power drawn from the bus

Description : The voltage control in electric supply networks in required on account of which of the following reasons ? (a) Adjustment of voltage at consumers premises within statutory limits (b) Control of ... daily and seasonal voltage variations in accordance with variations of load (d) All of the above

Last Answer : (d) All of the above

Description : Draw the circuit diagram for:- i) Measurement of active power in 3-phase load circuit using two wattmeter. ii) Measurement of reactive power in 3-phase load circuit using one wattmeter.

Last Answer : (i) Measurement of active power in 3- phase load circuit using two- wattmeter: (ii) Measurement of reactive power in 3- phase load circuit using one wattmeter

Description : Using illustrated chart, when will the power factor be least efficient? EL-0006 A. When the motor is operating at full load. B. When the percentage of slip is greatest. C. When there is no load on the motor. D. the power factor is the same from no-load to locked rotor.

Last Answer : Answer: C