The biggest advantage of T-T connection over the V-V connection of 3-phase power transformation is that it provides. 

1.a set of balanced voltages under load 2.a true 3-phase, 4-wire system 3.a higher ratio of utilization 4.more voltages 

2 Answers

Answer :

The biggest advantage of T-T connection over the V-V connection of 3-phase power transformation is that it provides. a true 3-phase, 4-wire system

Answer :

3 a higher ratio of utilization

Related questions

Description : AT-T connection has higher ratio of utilizax that n a V - V connection only when  1. Identical transformers are used  2. Load power factor is leading  3. Load power factor is unity  4. Non-identical transformers are used 

Last Answer : AT-T connection has higher ratio of utilizax that n a V - V connection only when Non-identical transformers are used 

Description : In conversion of 3-phase to 2-phase supply with T connection, the transformation ratio of the teaser will be__ times to that of main transformer: a) 1.732 b) 1.15 c) 0.866 d) Unity

Last Answer : Ans: C

Last Answer : Advantages of three phase transformer over bank of single phase transformers:  For identical magnitudes of power transformation, i) Saving in copper conductor. ii) Saving in electromagnetic core material. ... material such as insulating oil. v) Saving in overall cost. vi) Higher efficiency.

Description : What advantage has the star connection over the delta connection ?

Last Answer : A. Each star connection transformer is wound for only 57.7% of line voltage . In hv transmission, this admits of much smaller transformer being built for high voltage than possible with delta connection, because of less insulation.

Description : The chemical potential of a component (μi) of a phase is the amount by which its capacity for doing all work, barring work of expansion is increased per unit amount of substance added for an infinitesimal addition at constant temperature and ... , nj (C) (∂H/∂ni)S, P, nj (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Last Answer : What is the power factor when a single phase watt meter operating on 200 V and 5 A for 5 hours makes 2016 revolutions and the meter constant in revolution is 420? A) 0.04 B) 1.04 C) 0.96 D) None of these

Description : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is (A) 216 V (B) 226 V (C) 234 V (D) 236 V

Last Answer : A 230 V/460 V single-phase transformer operating at 20 A and unity power factor has primary referred resistance of 0.2 Ω and reactance of 0.5 Ω. The approximate primary induced emf is 226 V

Description : In a balanced 3 -phase 200 V circuit, the line current is 115.5 A. When the power is measured by two wattmeter method, one of the wattmeters reads 20 kW and the other one reads zero. What is the power factor of the load ?

Last Answer : In a balanced 3 -phase 200 V circuit, the line current is 115.5 A. When the power is measured by two wattmeter method, one of the wattmeters reads 20 kW and the other one reads zero. What is the power factor of the load ?  0.5

Description : A single-phase ac voltage source has 200 V rms and a system connected consumes an active power of 300 W. What is the reactive power consumed by the system if 2.5 A rms current is drawn ?  (a) 100 VAR (b) 200 VAR (c) 300 VAR (d) 400 VAR

Last Answer : A single-phase ac voltage source has 200 V rms and a system connected consumes an active power of 300 W. What is the reactive power consumed by the system if 2.5 A rms current is drawn ? 400 VAR

Description : Name two methods for measurement of low, medium and high resistance. Give one advantage and one limitation of V- I method.

Last Answer : Methods for measurement of low resistance:  1. Ammeter voltmeter method  2. Kelvin's bridge method  3. Ohm meter method  4. Potentiometer method  5. Digital/analog multi-meter ... must be infinity for perfectly accurate measurement which is not possible.  2. Connection errors.

Description : Explain MCB and ELCB with connection diagram supplying single phase load. 

Last Answer : OR OR Explanation: * MCB provides short circuit protection. * MCB provides overload protection * ELCB provides earth fault protection. * MCB is in series with ... occurs, the ELCB cuts off the power within the time of 0.1 sec. automatically to protect the personnel. 

Description : for Delta-Star connection of 3-phase transformer: i) Draw the connection diagram ii) List any two advantages of this connection iii) State its area of application. 

Last Answer : Disadvantages: i) In this type of connection, the secondary voltage is not in phase with the primary. Hence it is not possible to operate this connection in parallel with star-star or delta-delta ... iv) As line current is equal to phase current the conductor size of winding should be large. 

Description : State what is the significance of conducting phasing out test on a 3-phase transformer? Explain its procedure with a suitable connection diagram.

Last Answer : -Short primary & secondary winding of other phases expect the one under test. -Connect voltmeter to secondary winding. -A small DC current is circulated through the primary winding through ... . -The test repeated for finding out remaining concerned secondary windings in the same manner.

Last Answer : Advantages of open delta connection of 3-phase transformer:  1. When one of the phase in case of delta-delta bank is out of order by any reason, the service will be continued till ... demand in future (about 33%) will be supplied by converting open delta connection to delta-delta connection.

Description : The line voltage EL in a star connection is equal to.... (Ep = phase voltage)

Last Answer : The line voltage EL in a star connection is equal to √3 .Ep (Ep = phase voltage)

Description : Which of the following 3-phase connection of a transformer causes interference with the neighbouring communication lines:  (A) Delta-Star (B) Star-Delta (C) Delta-Delta (D) Star-Star

Last Answer : Which of the following 3-phase connection of a transformer causes interference with the neighbouring communication lines: Star-Star

Description : The Diamond Model assumes that: a) Multinational firms must develop global strategies based only on home demand conditions. b) Multinational firms must pay less attention to global consumers than domestic ... a firm plays a key role in shaping that firm's competitive advantage in global markets.

Last Answer : The national home base of a firm plays a key role in shaping that firm's competitive advantage in global markets.

Description : Hand-portable phase sequence indicators should be used when ____________. A. installing a new synchroscope B. preparing to make the shore power connection C. replacing a defective solenoid D. all of the above

Last Answer : Answer: B

Description : What is the advantage is obtained in the delta connection ?

Last Answer : A. When three transformer are obtained in delta, one may be removed and two remaining unit will carry 57.7% of the original three phase load and thus maintain the continuity of supply.

Description : What should be kVA rating of each transformer in V-V bank when three phase balanced load is 40 kVA ? (A) 19 (B) 28 (C) 37 (D) 23

Last Answer : What should be kVA rating of each transformer in V-V bank when three phase balanced load is 40 kVA ? (A) 19 (B) 28 (C) 37 (D) 23

Description : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Last Answer : What is the slip (as a percentage) when a 6 pole single phase induction motor operating on 220 V and 60 Hz is rotating at speed of 1140 rpm? A) 60% B) 5% C) 10% D) None of these

Description : When a V-V three phase transformer system is converted into a Δ-Δ system, increase in capacity of the system is (A) 86.6% (B) 50% (C) 57.7% (D) 73.2%

Last Answer : When a V-V three phase transformer system is converted into a Δ-Δ system, increase in capacity of the system is 73.2%

Description : At a particular instant, the R-phase voltage of a balanced 3-phase system is + 30 V, and the Y-phase voltage is – 90 V. The voltage of B-phase at that instant is (A) + 120 V (B) – 120 V (C) – 60 V (D) + 60 V

Last Answer : At a particular instant, the R-phase voltage of a balanced 3-phase system is + 30 V, and the Y-phase voltage is – 90 V. The voltage of B-phase at that instant is + 60 V

Description : The primary turns of a 444 V/222 V, 50 Hz single-phase transformer with a core cross-sectional area of 100 cm2, and a maximum flux density of 1.0 T is (A) 100 (B) 200 (C) 222 (D) 400

Last Answer : The primary turns of a 444 V/222 V, 50 Hz single-phase transformer with a core cross-sectional area of 100 cm2, and a maximum flux density of 1.0 T is 200

Description : A 12 -pole, 440 V, 50 Hz, 3 -phase synchronous motor takes a line current of 100 A at 0.8 pf leading. Neglecting losses, the torque developed will be

Last Answer : A 12 -pole, 440 V, 50 Hz, 3 -phase synchronous motor takes a line current of 100 A at 0.8 pf leading. Neglecting losses, the torque developed will be 1165 Nm

Description : Consider the following statements regarding three-phase transformers in Open -Delta (V -V) connections :  1. Being a temporary remedy when one transformer forms of Delta -Delta system is &imaged, and removed from service.  ... and 2 only (b) 1 and 3 only (c) 2 and 3 only (d) 1, 2 and 3

Last Answer : Consider the following statements regarding three-phase transformers in Open -Delta (V -V) connections :  1. Being a temporary remedy when one transformer forms of Delta -Delta system is &imaged, and removed from service.  ... and 2 only (b) 1 and 3 only (c) 2 and 3 only (d) 1, 2 and 3

Description : The meter constant of a single-phase 230 V induction watt hour meter is 400 revolutions per kWh. The speed of the meter disc for a current of 10 A of 0.9 pf lagging will be

Last Answer : The meter constant of a single-phase 230 V induction watt hour meter is 400 revolutions per kWh. The speed of the meter disc for a current of 10 A of 0.9 pf lagging will be 13.80 rpm

Description : One single-phase energy meter operating on 230 V and 5 A for 5 hours makes 1940 revolutions. Meter constant is 400 rev/kWh. The power factor of the load is

Last Answer : One single-phase energy meter operating on 230 V and 5 A for 5 hours makes 1940 revolutions. Meter constant is 400 rev/kWh. The power factor of the load is 0.8

Description : A two-phase generator is connected to two 90Ω load resistors. Each coil generates 120 V ac. The value of current flowing through the common neutral line will be: A. 1.33 A B. 1.88 A C. 2.66 A D. 1.77 A

Last Answer : A two-phase generator is connected to two 90Ω load resistors. Each coil generates 120 V ac. The value of current flowing through the common neutral line will be: 1.77 A

Description : RMS value of rectangular wave of period T, having a value of +V for a duration T1(

Last Answer : a

Description : How to share data connection with other devices on Samsung Galaxy V -Biology

Last Answer : answer:

Description : How to share data connection with other devices on Samsung Galaxy V Plus -Biology

Last Answer : answer:

Description : How to share data connection with other devices on Samsung Galaxy Tab 3 V -Biology

Last Answer : answer:

Description : A single phase, half-wave, controlled rectifier has 400 sin (314 t) as the input voltage and R as the load. For a firing angle of 60° for the SCR, the average output voltage is   (a) 240/π (b) 400/π (c) 300/π (d) 200/π 

Last Answer : C

Description : A three-phase synchronous motor has a terminal voltage of 460 V and a terminal current of 120 A at a power factor of 0.95 lagging, synchronous reactance of 1.68 ohm and the field current is 47 A. The field to armature mutual ... _____________.      (a). 20mH   (b). 16mH   (c). 24mH   (d). 22mH

Last Answer : 22

Description : A solar cell of 350 V is feeding power to an ac supply of 440 V, 50 Hz through a 3-phase fully controlled bridge converter. A large inductance is connected in the dc circuit to maintain the dc current at 20 A ... thyristor will be reverse biased for a period of  (A) 125o (B) 120o (C) 60o (D) 55o

Last Answer : A solar cell of 350 V is feeding power to an ac supply of 440 V, 50 Hz through a 3-phase fully controlled bridge converter. A large inductance is connected in the dc circuit to maintain the ... the solar cell resistance is 0.5 Ohm ,then each thyristor will be reverse biased for a period of 125o

Description : A single-phase, 230 V, 50 Hz ac mains fed step down transformer (4:1) is supplying power to a half-wave uncontrolled ac-dc converter used for charging a battery (12 V dc) with the series current limiting resistor being 19.04 Ohm. The charging current is  (A) 2.43 A (B) 1.65 A (C) 1.22 A (D) 1.0 A

Last Answer : A single-phase, 230 V, 50 Hz ac mains fed step down transformer (4:1) is supplying power to a half-wave uncontrolled ac-dc converter used for charging a battery (12 V dc) with the series current limiting resistor being 19.04 Ohm. The charging current is 1.0 A

Description : A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the ... the motor will be (A) 23.06 kW (B) 24.11 kW (C) 25.01 kW (D) 26.21 kW

Last Answer : A 400 V, 50 Hz 30 hp, three-phase induction motor is drawing 50 A current at 0.8 power factor lagging. The stator and rotor copper losses are 1.5 kW and 900 W respectively. The friction and windage losses are 1050 W and the core losses are 1200 W. The air-gap power of the motor will be 25.01 kW

Description : Joe and Sally were sitting in their family room one night. While Joe was watching T.V, his wife Sally was reading. All of a sudden the power went out and Joe decided to go to bed, but Sally kept on reading. With no use of artificial light, Sally kept on reading. How? -Riddles

Last Answer : Sally was blind, she was reading a book by Braille.

Description : Electric power a. V×I b. W/t c. V 2 /I d. E2 /t

Last Answer : . V×I

Description : Which of the following statements about a three-phase wye connection is correct? A. The line current is 1.73 times the phase current. B. The phase current is 1.73 times the line current. C. The line voltage is 1.73 times the phase voltage. D. The phase voltage is 1.73 times the line voltage.

Last Answer : Answer: C

Description : What will happen if transformer in parallel connection have different phase sequence ?

Last Answer : If the phase sequence is in an incorrect manner, in every cycle each pair of phases will get short-circuited.

Description : Explain with the neat circuit diagram only the scott connection scheme for conversion of three phase supply to two phase supply. Name one application of the same.

Last Answer : Three-phase to Two-phase Transformation (Scott Connection of Transformers): Working: i) Scott connection can be used for three-phase to two-phase conversion using two single-phase transformers ... a 3-phase system with a two-phase system with the flow of power in either direction. 

Description : Write the relation between phase and line current, phase and line voltage for Star connection.

Last Answer : Line voltage is equal to root three times of phase voltage and line and phase currents are equal in star connection

Description : Which three-phase connection can be used in a transformer to introduce a phase difference of 30o between its output and corresponding input line voltages  (A) Star-Star (B) Star-Delta (C) Delta-Delta (D) Delta-Zigzag

Last Answer : Which three-phase connection can be used in a transformer to introduce a phase difference of 30o between its output and corresponding input line voltages  (A) Star-Star (B) Star-Delta (C) Delta-Delta (D) Delta-Zigzag

Description : The transformer connection which has gained considerable popularity to serve 3-phase equipment and single phase lighting load is • Star/Star • Delta/Delta • Delta/Star • Star/Delta

Last Answer : The transformer connection which has gained considerable popularity to serve 3-phase equipment and single phase lighting load is Delta/Star

Last Answer : Direction of rotation of a split phase motor can be reversed by reversing the connection of either running winding or starting winding.

Description : What is a three phase connection?

Last Answer : RYB, 440 volt/phase

Description : How might Stacey feel when T. J. comes to the Logan house in the middle of the night Describe a connection that helps you answer the question.?

Last Answer : I think Stacy was upset because of what happened earlier

Description : Where do I find the "connection manager" so I can to the AT & T modem as instructed ?

Last Answer : i am trying to make a wireless connection via instructions from my AT & T provider. I was instructed to go to the connection manager--where do I find this?