There are two huge cooling towers close to building site of reactor __ and __ of the Chernobyl Power Plant.
a. 1&3
b. 4&5
c. 2&5
d. 1&4

1 Answer

Answer :

4&5

Related questions

Description : . There are two huge cooling towers close to building site of reactor __ and __ of the Chernobyl Power Plant. a. 1&3 b. 4&5 c. 2&5 d. 1&4

Last Answer : b. 4&5

Description : An important safety feature required at U.S. nuclear power plants that was not present at the Chernobyl Power Plant in the Soviet Union was the: w) reactor x) cooling water y) control rods z) containment building

Last Answer : ANSWER: Z -- CONTAINMENT BUILDING

Description : The hyperboloid cooling towers are often associated __ a. with nuclear power plants b. Used in some coal-fired plants c. In some large chemical and other industrial plants. d. All of the above.

Last Answer : All of the above

Description : How many cooling towers are there near a reactor a) 1 b) 4 c) 5 d) 2

Last Answer : b) 4

Description : . _____ type of cooling towers are used with nuclear power plants. a. Cross flow b. Natural draft c. Hyperbolic d. None of above

Last Answer : Hyperbolic

Description : Common applications of Cooling towers include a. Cooling the circulating water used in oil refineries b. petrochemical and other chemical plants c. thermal power stations d. All of the above.

Last Answer : All of the above.

Description : Natural draft cooling towers are mainly used in the _____. • Steel industry • Fertilizer industry • Alumina industry • Power stations

Last Answer : Power stations

Description : The hyperbolic cooling towers are associated with ……. and …….. power plants. a) electrical, thermal c) thermal, nuclear b) nuclear, electrical d) none of above

Last Answer : thermal, nuclear

Description : The __________ that are present depend on cooling tower building material, as well. Cooling towers are built of concrete, wood, plastic or metal. a. Heat b. Pollutants c. Cold d. All of Above

Last Answer : b. Pollutants

Description : World's worst radioactive pollution was caused by nuclear reactor disaster which occured in (A) Arizona (U.S.A.) (B) Chernobyl (undivided U.S.S.R.) (C) Pennsylvania (U.S.A.) (D) Moscow (U.S.S.R.)

Last Answer : (B) Chernobyl (undivided U.S.S.R.)

Description : There are _______main types of cooling towers that are defined by how water or air passes through them. a. One b. Two c. Three d. Four

Last Answer : three

Description : In hyperboloid cooling towers the material is filled at 1. Tower’s bottom 2. Tower’s top 3. Near tower 4. None of above

Last Answer : Tower’s top

Description : Cooling towers operate through a ____process that efficiently cools the already cycled water to be reused. 1. Heat exchange 2. Heat expand 3. Heat transfer 4. None of above

Last Answer : Heat transfer

Description : How many times chlorination must be carried out for cooling towers 1. Twice a year 2. Once a year 3. Thrice a year 4. None of above

Last Answer : Twice a year

Description : How does the flow of air occur in natural draught cooling towers? a) Natural pressure head density between cold outside air and humid inside air b) Variation in pressure of both cold outside air and ... given air vents and vacuum ports d) Because of difference in the volume of both the of airs

Last Answer : Natural pressure head density between cold outside air and humid inside air

Description : Thermal efficiencies up to........have been observed in hybrid cooling towers a. 92 b. 82 c. 72 d. 62

Last Answer : 92

Description : . Improved cooling efficiency and minimum usage of material are the key features of ______ a. Natural draft cooling towers b. Cross flow towers c. Hyperbolic cooling d. All of above

Last Answer : Hyperbolic cooling

Description : Hyperbolic cooling towers are also referred as a. Natural draft towers b. Cross flow towers c. Hyperboloid towers d. None of the above

Last Answer : Hyperboloid towers

Description : Which type of cooling towers operate through a chimney or stack ___ a. Cross flow b. Counter flow c. Hyperbolic d. All of above

Last Answer : Hyperbolic

Description : . ______ type of cooling towers are structurally strong. a. Counter flow towers b. Hyperbolic towers c. Cross flow towers d. None of the above

Last Answer : Hyperbolic towers

Description : Hyperbolic cooling towers have become design standard for all natural draft structural towers because usage of . a. Their structural strength b. Minimum usage of material. c. Improving cooling efficiency d. All of the above.

Last Answer : All of the above.

Description : Which one of the following fill material is more energy efficient for cooling towers in case of sea water cooling? • Splash fill • Film fill • Low clog film fill • None of the above

Last Answer : Film fill

Description : Hyperbolic cooling towers are made up of high height reinforced ………structure. a) plastic c)metal b) alloy d) concrete

Last Answer : concrete

Description : How does the flow of air occur in natural draught cooling towers? a) Natural pressure head density between cold outside air and humid inside air b) Variation in pressure of both cold outside air and ... given air vents and vacuum ports d) Because of difference in the volume of both the of airs

Last Answer : Natural pressure head density between cold outside air and humid inside air

Description : . Most cooling towers are capacity rated at a "standard" wet bulb temperature of ___of • 72°F • 52°F • 78°F • 75°F

Last Answer : 78°F

Description : __________ Cooling towers have become the design standard for all natural-draft cooling towers because oftheir structural strength and minimum usage of material. • HCT • CCT • Hyperboloid • None

Last Answer : Hyperboloid

Description : Cooling towers vary in size from small roof-top units to very large hyperboloid structures that can be up to ____meters tall and _____ meters in diameter, or rectangular structures that can be over 40 meters tall and 80 meters long. a. 200&100 b. 100&50 c. 200&50 d. 200 &150

Last Answer : 200&100

Description : Cooling towers vary in size from small roof-top units to very large hyperboloid structures that can be up to ____ meters tall and _____ meters in diameter, or rectangular structures that can be over 40 meters tall and 80 meters long. a. 200&100 b. 100&50 c. 200&50 d. 200 &150

Last Answer : a. 200&100

Description : Why cooling towers require in the Steam power plant ?

Last Answer : Cooling towers cool the warm water discharged from the condenser and feed the cooled water back to the condenser. There are two types of cooling methods provided in the cooling towers, they can be either ... finned tubes over which cooling air is passed. Heat is rejected to air as water is cooled

Description : What are built to cool down the cooling water in a power plant 1 Towers 2 Cooling pond 3 Air filter 4 non of these

Last Answer : 1 Towers

Description : Hyperbolic cooling towers used in a) Coal-fired power plant b) Nuclear plants c) Thermal power plant d) All of these

Last Answer : d) All of these

Description : Air intake for an air compressor should be preferably taken from (A) A site, where cooling towers are located nearby (B) A site, where open coal yard in located nearby (C) An air conditioned room maintained at a temperature of 18°C (D) An outside atmosphere at 10°C

Last Answer : (D) An outside atmosphere at 10°C

Description : What type of cooling system is used in the large power plants? a. Cooling ponds b. Natural flow system c. Cooling towers d. Single deck system

Last Answer : c. Cooling towers

Description : Hyperbolic cooling towers generally used in the a) Steel industry b) Fertilizer industry c) Alumina industry d) Power industry

Last Answer : d) Power industry

Description : What type of cooling system is used in the large power plants? A] Cooling ponds B] Natural flow system C] Cooling towers. D] Single deck system

Last Answer : C] Cooling towers.

Description : The part of a nuclear power plant that prevents thermal pollution of lakes or rivers is the: w) reactor x) coolant/moderator y) cooling tower z) control rod

Last Answer : ANSWER: Y -- COOLING TOWER

Description : The cooling water reduces the water temperature close to _____. • Dry bulb temperature • Ambient wet bulb temperature • Dew point temperature • None of the above

Last Answer : Ambient wet bulb temperature

Description : The pollutants that are present depend on __________ building material, as well. • Cooling tower • Water tower • Steam tower • Fire tower

Last Answer : cooling water

Description : Cooling towers are rated in terms of A. approach B. range C. both of the mentioned D. none of the mentioned

Last Answer : ANSWER :C

Description : What is the working principle of Cooling Towers?

Last Answer : The hot water is sprayed from the top of the tower, while the air is made to flow from the bottom of the tower to the top. This air cools the hot water in the cooling tower. Air vaporises ... and leaves at the top of the tower and cooled water leaves at the bottom and recirculated to the condenser.

Description : What is meant by cooling Towers?

Last Answer : It is a tower or building like device in which atmospheric air circulates in direct or indirect contact with warmer water and water is thereby cooled. Cooling towers may either use the evaporation of water to remove process heat and cool the working fluid

Description : Pick out the wrong statement. (A) With decrease in feed temperature, the number of plates required for binary distillation decreases for a given L/V' ratio (B) The extraction per unit ... and its cross￾section is wider at the bottom (D) Vander wall adsorption is also called chemisorption

Last Answer : (D) Vander wall adsorption is also called chemisorption

Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Description : Water entrained by circulating air in cooling towers is termed as (A) Drift (B) Blow down (C) Vapor load (D) None of these

Last Answer : (A) Drift

Description : In case of cooling towers, the ratio of the rates of heat and mass transfer is indicated by the __________ number. (A) Lewis (B) Grashoff (C) Sherwood

Last Answer : (A) Lewis

Description : How The Dry Type Cooling Towers Are Classified?

Last Answer : The dry type cooling towers are classified into two types ‘as follows: 1. Indirect dry type (or) Heller cooling system 2. Direct dry type-cooling system

Description : How Mechanical Draft Cooling Towers Are Classified?

Last Answer : Mechanical draft cooling tower is classified into three types: 1. Forced draft tower. 2. Induced draft counterflow tower. 3. Induced draft cross flow tower.

Description : How The Atmospheric (or) Natural Draught Cooling Towers Are Classified?

Last Answer : In atmospheric (or) natural cooling towers, the natural air provides the required cooling without the use of fans. This is classified into three types: 1. Natural draft spray filled towers. 2. Natural draft packed type towers. 3. Hyperbolic cooling towers.

Description : Name Different Types Of Cooling Towers?

Last Answer : The cooling towers are classified as follows. According to the construction of material: 1. Timber for small tower 2. Ferro concrete for large capacity stations. 3. Multi deck concrete towers for ... air draught: 1. Atmospheric (or) Natural draught cooling system 2. Mechanical draught cooling tower.

Description : What Is The Working Principle Of Cooling Towers?

Last Answer : The hot water is sprayed from the top of the tower, while the air is made to flow from the bottom of the tower to the top. This air cools the hot water in the cooling tower. Air evaporates ... and leaves at the top of the tower and cooled water leaves at the bottom and recirculated to the condenser.