The pollutants that are present depend on __________ building material, as well.
• Cooling tower
• Water tower
• Steam tower
• Fire tower

1 Answer

Answer :

cooling water

Related questions

Description : The __________ that are present depend on cooling tower building material, as well. Cooling towers are built of concrete, wood, plastic or metal. a. Heat b. Pollutants c. Cold d. All of Above

Last Answer : b. Pollutants

Description : What are present depend on cooling tower building material as well 1 pollution 2 population 3 dust 4 none of these

Last Answer : 1 pollution

Description : Which of the following gives out highest pollutants to the atmosphere 1 cooling tower 2 water tower 3 steam tower 4 fire tower

Last Answer : 3 steam tower

Description : The ……….-induced response of cooling tower is the key factor to improve safety and to reduce tower crack. a) wind c) heat b) water d) steam

Last Answer : wind

Description : A __________ is a type of heat exchange system where water is heated to its' boiling point via combustion of a fuel blown through a tube submerged in water. a. Condensate loop b. Hyperbolic cooling tower c. Steam boiler d. All of above

Last Answer : c. Steam boiler

Description : In hyperboloid cooling towers the material is filled at 1. Tower’s bottom 2. Tower’s top 3. Near tower 4. None of above

Last Answer : Tower’s top

Description : In cooling tower ,higher temperature __________ corrosion potential • Decrease • Increase • Temperature has no effect on corrosion

Last Answer : Increase

Description : For steam power plant having capacity 600 MW capacity a cooling tower is required to set up with condenser. Suggest the type of condenser and cooling tower with justification. 

Last Answer : For Steam power plant having Capacity 600 MW the requirement of condenser and cooling tower is as follow. 1) Condenser:- Given Capacity is medium to low capacity for this we can use Jet Condenser ... and efficiency of tower is high  -Temperature of water coming out from tower can be controlled.

Description : Which among the following are the components of natural draft cooling tower a) Supply basin b) reinforced concrete c) Hot water distribution d) none of the above

Last Answer : reinforced concrete

Description : The ratio of dissolved solids in circulating water to the dissolved solids in makeup water is called a) Liquid gas ratio b) Cycle of concentration c) Cooling tower effectiveness d) None of the above

Last Answer : Cycle of concentration

Description : Which one of the following is true to estimate the range of cooling tower? a) Range = cooling water inlet temperature - wet bulb temperature b) Range = cooling water outlet temperature - wet bulb temperature ... = heat load in kcal per hour / water circulation in lines per hour d) None of the above

Last Answer : Range = heat load in kcal per hour / water circulation in lines per hour

Description : In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : Which of the following is the simplest method of cooling the condenser water? • Spray cooling pond • Cooling tower • Indirect air cooling • Hyperbolic cooling tower

Last Answer : Spray cooling pond

Description : In which system is Cooling of hot water is done on tray as step by? a. Mechanical draught cooling system b. Hyperbolic cooling tower c. Atmospheric cooling tower d. Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : L/G ratio in a cooling tower is a ratio of _____. • Length and girth • Length and temperature gradient • Water flow rate and air mass flow rate • Air mass flow rate and water flow rate

Last Answer : Water flow rate and air mass flow rate

Description : The ratio of dissolved solids in circulating water to dissolved solids in makeup water is called. • Liquid gas ratio • Cycle of concentration • Cooling tower effectiveness • None of the above

Last Answer : Cycle of concentration

Description : . In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : In ________ cooling tower there is no direct contact between the water and Air. • Dry type • Evaporative type • Once through • All of the above

Last Answer : All of the above

Description : How do you service a cooling tower? • Ensure Proper Airflow. . Clean Your Tubes. • Inspect the Water Pump. • All of above

Last Answer : all of above

Description : . How can we increase the efficiency of a cooling tower? a. Save energy. b. Reduce the amount of water being consumed. c. Decrease the amount of chemicals required for water treatment. d. All of above

Last Answer : All of above

Description : A ______ is a specialized heat exchanger in which air and water are brought into direct contact with each otherin order to reduce the water's temperature. a. Cooling tower b. Heating tower c. Both d. All are wrong

Last Answer : cooling tower

Description : How do you service a cooling tower? • Ensure Proper Airflow. Clean Your Tubes. • Inspect the Water Pump. • All of above

Last Answer : All of above

Description : How can we increase the efficiency of a cooling tower? a. Save energy. b. Reduce the amount of water being consumed. c. Decrease the amount of chemicals required for water treatment. d. All of above

Last Answer : d. All of above

Description : Pollution caused by cooling tower includes 1. Fouling 2. Limestone formation 3. Corrosion 4. All of above

Last Answer : All of above

Description : In the natural draft cooling tower_________ is not required a) Fan b) tower c) Nozzle d) none of the above

Last Answer : Fan

Description : In natural draft cooling tower the air flow is obtained by___________ a) Difference in air pressure b) difference in air temperature c) Difference in air speed d) none of the above

Last Answer : Difference in air pressure

Description : Cooling tower is a ______device a) Heat absorption b) heat rejection c) Both a and b c) neither a nor b

Last Answer : heat rejection

Description : Cooling tower effectiveness is the ratio of a) Range/( Range + approach) b) Approach/(range + approach) c) Range /(range - approach) d) Approach/ /(range - approach)

Last Answer : Range/( Range + approach)

Description : Natural draft cooling tower are mainly used in a) Steel Industry b) Alumina industry c) Fertilizer industry d) Power station

Last Answer : Power station

Description : How is air produced in mechanical draught cooling tower? a) Air Tuyeres b) Propeller fans c) Air blowers d) Louvre

Last Answer : Propeller fans

Description : The first hyperbolic cooling tower was built in... a. 1916 b. 1917 c. 1918 d. 1919

Last Answer : 1918

Description : Normally the guaranteed best approach a cooling tower can achieve is _____. • 5°C • 12°C • 8°C • 2.8°C

Last Answer : 2.8°C

Description : Cooling tower effectiveness is the ratio of _____. • Range/(range + approach) • Approach/(range + approach) • Range/ Approach • Approach/ Range

Last Answer : Range/(range + approach)

Description : A better indicators for cooling tower performance is _____. • Wet bulb temperature • Dry bulb temperature • Range • Approach

Last Answer : Approach

Description : Cooling efficiency of a cooling tower is significantly affected under cross-wind condition and might decrease to……… in the range of moderate to high wind velocity condition. a) 50% c) 25% b) 75% d) 90%

Last Answer : 75%

Description : The first hyperboloid shaped cooling tower was introduced by the Dutch engineers Frederik van Iterson andGerard Kuypers and built in ……….. a) 1918 c) 1919 b) 1870 d) 1920

Last Answer : 1918

Description : Which of the following faction affect the cooling tower performance? • The range • Heat load • Wet bulb temperature • All of the above

Last Answer : All of the above

Description : When sizing a cooling tower the highest anticipate__________ should be used? • Dry bulb • Wet bulb • Both dry and wet bulb • None of the above

Last Answer : Wet bulb

Description : . Potable water means the water used for (A) Fire-fighting (B) Cooling (C) Drinking (D) Evaporation to produce steam

Last Answer : (C) Drinking

Description : __________ Cooling towers have become the design standard for all natural-draft cooling towers because oftheir structural strength and minimum usage of material. • HCT • CCT • Hyperboloid • None

Last Answer : Hyperboloid

Description : A packed tower compared to a plate tower for a particular mass transfer operation (A) Incurs smaller pressure drop (B) Allows installation of cooling coils (C) Is less costly when built in large sizes/diameters (D) Is more suitable, if suspended solids are present in fluid stream

Last Answer : (A) Incurs smaller pressure drop

Description : The temperature of water cooled in cooling tower is always __________ temperature of entering air. (A) More than the wet bulb (B) Less than the wet bulb (C) Equal to the wet bulb (D) Equal to the dry bulb

Last Answer : (A) More than the wet bulb

Description : The minimum temperature to which the water can be cooled in a cooling tower is the __________ temperature of air. (A) Ambient (B) Dry bulb (C) Dew point (D) Wet bulb

Last Answer : C) Dew point

Description : Minimum temperature upto which water can be theoretically cooled down in the cooling tower by evaporative cooling is equal to the __________ temperature of air. (A) Wet bulb (B) Dry bulb (C) Saturation (D) Dew point

Last Answer : Option A

Description : When the temperature and humidity of air is low, we usually use __________ draft cooling tower. (A) Natural (B) Forced (C) Induced (D) None of these

Last Answer : (A) Natural

Description : __________ number indicates the ratio of the rates of the heat and mass transfer incase of a cooling tower. (A) Sherwood (B) Stanton (C) Lewis (D) Peclet

Last Answer : (C) Lewis

Description : A natural draft cooling tower is filled with wooden grids, which covers about __________ percent of the tower height. (A) 10-15 (B) 30-40 (C) 70-80 (D) 90-100

Last Answer : (A) 10-15

Description : There are two huge cooling towers close to building site of reactor __ and __ of the Chernobyl Power Plant. a. 1&3 b. 4&5 c. 2&5 d. 1&4

Last Answer : 4&5

Description : . There are two huge cooling towers close to building site of reactor __ and __ of the Chernobyl Power Plant. a. 1&3 b. 4&5 c. 2&5 d. 1&4

Last Answer : b. 4&5

Description : Most commonly used crude heater before the fractionation tower in a refinery is the __________ heater. (A) Electric immersion (B) Pipestill (C) Steam coil (D) None of these

Last Answer : (B) Pipestill