Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature
Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature
Description : Which one of the following is true to estimate the range of cooling tower? a) Range = cooling water inlet temperature - wet bulb temperature b) Range = cooling water outlet temperature - wet bulb temperature ... = heat load in kcal per hour / water circulation in lines per hour d) None of the above
Last Answer : Range = heat load in kcal per hour / water circulation in lines per hour
Description : The cooling water reduces the water temperature close to _____. • Dry bulb temperature • Ambient wet bulb temperature • Dew point temperature • None of the above
Last Answer : Ambient wet bulb temperature
Description : A better indicators for cooling tower performance is _____. • Wet bulb temperature • Dry bulb temperature • Range • Approach
Last Answer : Approach
Description : Which of the following faction affect the cooling tower performance? • The range • Heat load • Wet bulb temperature • All of the above
Last Answer : All of the above
Description : Hyperbolic cooling towers have become design standard for all natural draft structural towers because usage of . a. Their structural strength b. Minimum usage of material. c. Improving cooling efficiency d. All of the above.
Last Answer : All of the above.
Description : __________ Cooling towers have become the design standard for all natural-draft cooling towers because oftheir structural strength and minimum usage of material. • HCT • CCT • Hyperboloid • None
Last Answer : Hyperboloid
Description : When sizing a cooling tower the highest anticipate__________ should be used? • Dry bulb • Wet bulb • Both dry and wet bulb • None of the above
Last Answer : Wet bulb
Description : Cooling towers are rated in terms of A. approach B. range C. both of the mentioned D. none of the mentioned
Last Answer : ANSWER :C
Description : Wet cooling towers operate on the principle of ............... A Condensation. B Evaporative Cooling C Both of the above D None of the above
Last Answer : B Evaporative Cooling
Description : Wet cooling towers (or open circuit cooling towers) operate on the principle of ............... A] Condensation. B] Evaporative cooling C] Both of the above D] None of the above
Last Answer : B] Evaporative cooling
Description : Which of the following remains constant during evaporative cooling process with recirculated water supply? (A) Relative humidity (B) Partial pressure of vapour (C) Wet bulb temperature (D) None of these
Last Answer : (C) Wet bulb temperature
Description : The term "cooling range" in a cooling tower refers to the difference in the temperature of (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air (B) Hot water entering the ... air (C) Hot water entering the tower and the cooled water leaving the tower (D) None of these
Last Answer : (C) Hot water entering the tower and the cooled water leaving the tower
Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)
Last Answer : (C) Both (A) & (B)
Description : Can a cooling tower cool water below the wet bulb temperature of inlet air? (A) Yes (B) No (C) Yes; but height of cooling tower will be prohibitively high (D) Yes; but the air flow rate should be excessively high
Last Answer : (B) No
Description : Pick out the wrong statement. (A) Different solids have different equilibrium moisture curves (B) Total condenser or reboiler is considered equivalent to one theoretical plate in McCabe-Thiele method of ... (D) Even a forced draft cooling tower cannot cool water below the wet bulb temperature
Last Answer : (C) Heat removal load on cooler remains constant, even with increase of the reflux ratio in a distillation column
Description : The term "approach" in a cooling tower refers to the difference in the temperature of the (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air (B ... (C) Hot water entering and the cooled water leaving the cooling tower (D) None of these
Last Answer : (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air
Description : During dehumidification of unsaturated air wet bulb temperature & partial pressure of vapor are not constant. However, during evaporative cooling process with recirculated water supply, the __________ remains ... pressure of water vapor (C) Relative humidity (D) None of these
Last Answer : (A) Wet bulb temperature
Description : Which of the following decreases during evaporative cooling process with recirculated water supply? (A) Wet bulb temperature (B) Relative humidity (C) Partial pressure of vapour (D) None of these
Last Answer : (D) None of these
Description : The temperature of water cooled in cooling tower is always __________ temperature of entering air. (A) More than the wet bulb (B) Less than the wet bulb (C) Equal to the wet bulb (D) Equal to the dry bulb
Last Answer : (A) More than the wet bulb
Description : Pick out the wrong statement (A) A horizontal line on the humidity chart indicates the temperature changes at constant molal humidity (B) When water is cooled from 80 to 70°C by exposure ... & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure
Last Answer : (D) Relative saturation of unsaturated mixture of water vapor & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure
Description : Which of the following increases during evaporative cooling process with recirculated water supply? (A) Wet bulb temperature (B) Relative humidity (C) Partial pressure of vapour (D) Both (B) and (C)
Last Answer : (D) Both (B) and (C)
Description : During sensible cooling process (A) Relative humidity decreases (B) Relative humidity increases (C) Wet bulb temperature decreases (D) Both (B) and (C)
Description : Which of the following psychrometric processes is followed by water vapour laden unsaturated air, when it is passed through solid or liquid adsorbent? (A) Cooling and dehumidification ... (C) Dehumidification with dry bulb temperature remaining constant (D) None of these
Last Answer : (B) Heating and dehumidification at almost constant wet bulb temperature
Description : The minimum temperature to which the water can be cooled in a cooling tower is the __________ temperature of air. (A) Ambient (B) Dry bulb (C) Dew point (D) Wet bulb
Last Answer : C) Dew point
Description : During sensible cooling of air, its wet bulb temperature (A) Decreases but dew point remains constant (B) Increases but dew point remains constant (C) Increases & the dew point decreases (D) Decreases & the dew point increases
Last Answer : (B) Increases but dew point remains constant
Description : Moist air is cooled along the line of constant __________ , when it is passed over a cold & dry cooling coil, such that no condensation occurs? (A) Enthalpy (B) Relative humidity (C) Wet bulb temperature (D) Dew point temperature
Last Answer : (D) Dew point temperature
Description : Minimum temperature upto which water can be theoretically cooled down in the cooling tower by evaporative cooling is equal to the __________ temperature of air. (A) Wet bulb (B) Dry bulb (C) Saturation (D) Dew point
Last Answer : Option A
Description : __________ remains constant during the adiabatic cooling of moist air. (A) Wet bulb temperature (B) Dry bulb temperature (C) Relative humidity (D) Specific humidity
Description : In hyperboloid cooling towers the material is filled at 1. Tower’s bottom 2. Tower’s top 3. Near tower 4. None of above
Last Answer : Tower’s top
Description : Cooling towers operate through a ____process that efficiently cools the already cycled water to be reused. 1. Heat exchange 2. Heat expand 3. Heat transfer 4. None of above
Last Answer : Heat transfer
Description : How many times chlorination must be carried out for cooling towers 1. Twice a year 2. Once a year 3. Thrice a year 4. None of above
Last Answer : Twice a year
Description : How does the flow of air occur in natural draught cooling towers? a) Natural pressure head density between cold outside air and humid inside air b) Variation in pressure of both cold outside air and ... given air vents and vacuum ports d) Because of difference in the volume of both the of airs
Last Answer : Natural pressure head density between cold outside air and humid inside air
Description : Thermal efficiencies up to........have been observed in hybrid cooling towers a. 92 b. 82 c. 72 d. 62
Last Answer : 92
Description : . Improved cooling efficiency and minimum usage of material are the key features of ______ a. Natural draft cooling towers b. Cross flow towers c. Hyperbolic cooling d. All of above
Last Answer : Hyperbolic cooling
Description : . _____ type of cooling towers are used with nuclear power plants. a. Cross flow b. Natural draft c. Hyperbolic d. None of above
Last Answer : Hyperbolic
Description : Hyperbolic cooling towers are also referred as a. Natural draft towers b. Cross flow towers c. Hyperboloid towers d. None of the above
Last Answer : Hyperboloid towers
Description : Which type of cooling towers operate through a chimney or stack ___ a. Cross flow b. Counter flow c. Hyperbolic d. All of above
Description : . ______ type of cooling towers are structurally strong. a. Counter flow towers b. Hyperbolic towers c. Cross flow towers d. None of the above
Last Answer : Hyperbolic towers
Description : The hyperboloid cooling towers are often associated __ a. with nuclear power plants b. Used in some coal-fired plants c. In some large chemical and other industrial plants. d. All of the above.
Description : Common applications of Cooling towers include a. Cooling the circulating water used in oil refineries b. petrochemical and other chemical plants c. thermal power stations d. All of the above.
Description : Which one of the following fill material is more energy efficient for cooling towers in case of sea water cooling? • Splash fill • Film fill • Low clog film fill • None of the above
Last Answer : Film fill
Description : Natural draft cooling towers are mainly used in the _____. • Steel industry • Fertilizer industry • Alumina industry • Power stations
Last Answer : Power stations
Description : The hyperbolic cooling towers are associated with ……. and …….. power plants. a) electrical, thermal c) thermal, nuclear b) nuclear, electrical d) none of above
Last Answer : thermal, nuclear
Description : Hyperbolic cooling towers are made up of high height reinforced ………structure. a) plastic c)metal b) alloy d) concrete
Last Answer : concrete
Description : Cooling towers vary in size from small roof-top units to very large hyperboloid structures that can be up to ____meters tall and _____ meters in diameter, or rectangular structures that can be over 40 meters tall and 80 meters long. a. 200&100 b. 100&50 c. 200&50 d. 200 &150
Last Answer : 200&100
Description : There are two huge cooling towers close to building site of reactor __ and __ of the Chernobyl Power Plant. a. 1&3 b. 4&5 c. 2&5 d. 1&4
Last Answer : 4&5
Description : There are _______main types of cooling towers that are defined by how water or air passes through them. a. One b. Two c. Three d. Four
Last Answer : three