Water entrained by circulating air in cooling towers is termed as

(A) Drift

(B) Blow down

(C) Vapor load

(D) None of these

1 Answer

Answer :

(A) Drift

Related questions

Description : Drift in a cooling tower is (A) The water entrained by the circulating air (B) Dependent on the water lost by evaporation (C) Desirable (D) All (A), (B) & (C)

Last Answer : (A) The water entrained by the circulating air

Description : Common applications of Cooling towers include a. Cooling the circulating water used in oil refineries b. petrochemical and other chemical plants c. thermal power stations d. All of the above.

Last Answer : All of the above.

Description : Pick out the wrong statement. (A) Recycled coarse material to the grinder by a classifier is termed as circulating load (B) Wear and tear in wet crushing is more than that in dry crushing of ... a pipeline which permits the solids to settle down due to reduction in velocity of the dust laden gas

Last Answer : (C) Size enlargement (opposite of size reduction) is not a mechanical operation

Description : Which of the following accessories is provided in the vapor line of an evaporator for removing the entrained liquid? (A) Bleed point (B) Vent (C) Catchall (D) Baffle

Last Answer : (C) Catchall

Description : The purpose of providing a 'catchall' in the vapor line of an evaporator is to (A) Create vacuum (B) Regulate the vapor flow (C) Vent the non-condensable gases (D) Arrest the entrained liquid

Last Answer : (D) Arrest the entrained liquid

Description : If the voids of a soil mass are full of air only, the soil is termed as (A) Air entrained soil (B) Partially saturated soil (C) Dry soil (D) Dehydrated soil

Last Answer : Option C

Description : What are built to cool down the cooling water in a power plant 1 Towers 2 Cooling pond 3 Air filter 4 non of these

Last Answer : 1 Towers

Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Description : Air intake for an air compressor should be preferably taken from (A) A site, where cooling towers are located nearby (B) A site, where open coal yard in located nearby (C) An air conditioned room maintained at a temperature of 18°C (D) An outside atmosphere at 10°C

Last Answer : (D) An outside atmosphere at 10°C

Description : Blowdown in a cooling tower (A) Means discarding a small fraction of circulating water to prevent and limit the concentration of salt and impurities (B) Increases the scale forming tendencies of water (C) Is undesirable (D) All (A), (B) & (C)

Last Answer : (A) Means discarding a small fraction of circulating water to prevent and limit the concentration of salt and impurities

Description : During dehumidification of unsaturated air wet bulb temperature & partial pressure of vapor are not constant. However, during evaporative cooling process with recirculated water supply, the __________ remains ... pressure of water vapor (C) Relative humidity (D) None of these

Last Answer : (A) Wet bulb temperature

Description : Pick out the wrong statement (A) A horizontal line on the humidity chart indicates the temperature changes at constant molal humidity (B) When water is cooled from 80 to 70°C by exposure ... & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Last Answer : (D) Relative saturation of unsaturated mixture of water vapor & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Description : There are _______main types of cooling towers that are defined by how water or air passes through them. a. One b. Two c. Three d. Four

Last Answer : three

Description : How does the flow of air occur in natural draught cooling towers? a) Natural pressure head density between cold outside air and humid inside air b) Variation in pressure of both cold outside air and ... given air vents and vacuum ports d) Because of difference in the volume of both the of airs

Last Answer : Natural pressure head density between cold outside air and humid inside air

Description : How does the flow of air occur in natural draught cooling towers? a) Natural pressure head density between cold outside air and humid inside air b) Variation in pressure of both cold outside air and ... given air vents and vacuum ports d) Because of difference in the volume of both the of airs

Last Answer : Natural pressure head density between cold outside air and humid inside air

Description : Make up water is required in a cooling tower to replace the water lost by (A) Evaporation (B) Drift (C) Blowdown and leakage (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : The ratio of dissolved solids in circulating water to the dissolved solids in makeup water is called a) Liquid gas ratio b) Cycle of concentration c) Cooling tower effectiveness d) None of the above

Last Answer : Cycle of concentration

Description : The ratio of dissolved solids in circulating water to dissolved solids in makeup water is called. • Liquid gas ratio • Cycle of concentration • Cooling tower effectiveness • None of the above

Last Answer : Cycle of concentration

Description : Which of the following employs an accessory known as 'drift eliminator'? (A) Multiple effect evaporator (B) Mechanical draft cooling tower (C) Rotary dryer (D) Rotating disc contacto

Last Answer : (B) Mechanical draft cooling tower

Description : cooling is the process of dissipating the armature and field winding losses to a cooling medium circulating within the winding insulation wall (a) Direct (b) Indirect (c) Conventional (d) Any ofthe above

Last Answer : (a) Direct

Description : Pick out the wrong statement. (A) With decrease in feed temperature, the number of plates required for binary distillation decreases for a given L/V' ratio (B) The extraction per unit ... and its cross￾section is wider at the bottom (D) Vander wall adsorption is also called chemisorption

Last Answer : (D) Vander wall adsorption is also called chemisorption

Description : In case of cooling towers, the ratio of the rates of heat and mass transfer is indicated by the __________ number. (A) Lewis (B) Grashoff (C) Sherwood

Last Answer : (A) Lewis

Description : gas which is collected over water becomes moistened due to water vapor, exerts its own partial pressure at the gas temperature, which is termed as its (A) Aqueous tension (B) Saturated humidity (C) Vapor pressure

Last Answer : Option A

Description : While designing an air entrained concrete (A) Water cement ratio is reduced (B) Proportion of aggregates is reduced (C) An allowance for the entrained air is made (D) All the above

Last Answer : (D) All the above

Description : Vapor phase reaction of ammonia & nitric acid to produce ammonium nitrate is termed as the __________ process. (A) Haber's (B) Stengel (C) Le-chatelier's (D) Du-pont's

Last Answer : (B) Stengel

Description : The entrained air in concrete (A) Increases workability (B) Decreases workability (C) Decreases resistance to weathering (D) Increases stress

Last Answer : Answer: Option A

Description : A concrete using an air entrained cement (A) Has strength less than 10% to 15% (B) Has more resistance to weathering (C) Is more plastic and workable (D) Is free from segregation and bleeding

Last Answer : Answer: Option C

Description : The entrained air in concrete [ A ] Increases the strength [ B ] Decreases the resistance to weathering [ C ] Increases the workability [ D ] Decreases the workability

Last Answer : [ C ] Increases the workability

Description : Which one of the following the maximum effect on cooling tower performance A Fill media B Drift C Lourvers D Casing

Last Answer : A Fill media

Description : What Are The Factors That Affect The Rate Of Evaporation Of Water In Cooling Towers?

Last Answer :  Amount of water surface area exposed.  The time of exposure.  The relative velocity of air passing over the droplets.  The RH of air.  The direction of airflow relative to water.

Description : Cooling towers operate through a ____process that efficiently cools the already cycled water to be reused. 1. Heat exchange 2. Heat expand 3. Heat transfer 4. None of above

Last Answer : Heat transfer

Description : Which one of the following fill material is more energy efficient for cooling towers in case of sea water cooling? • Splash fill • Film fill • Low clog film fill • None of the above

Last Answer : Film fill

Description : Pick out the wrong statement. (A) The condensing film co-efficient is about 3 times lower for vertical condenser as compared to the equivalent horizontal condenser for identical situation ( ... in a heat exchanger is controlled by the value of the film co-efficient, which is higher

Last Answer : (D) Overall heat transfer co-efficient in a heat exchanger is controlled by the value of the film co-efficient, which is higher

Description : Cooling towers are rated in terms of A. approach B. range C. both of the mentioned D. none of the mentioned

Last Answer : ANSWER :C

Description : Why cooling towers require in the Steam power plant ?

Last Answer : Cooling towers cool the warm water discharged from the condenser and feed the cooled water back to the condenser. There are two types of cooling methods provided in the cooling towers, they can be either ... finned tubes over which cooling air is passed. Heat is rejected to air as water is cooled

Description : What is the working principle of Cooling Towers?

Last Answer : The hot water is sprayed from the top of the tower, while the air is made to flow from the bottom of the tower to the top. This air cools the hot water in the cooling tower. Air vaporises ... and leaves at the top of the tower and cooled water leaves at the bottom and recirculated to the condenser.

Description : What is meant by cooling Towers?

Last Answer : It is a tower or building like device in which atmospheric air circulates in direct or indirect contact with warmer water and water is thereby cooled. Cooling towers may either use the evaporation of water to remove process heat and cool the working fluid

Description : How The Dry Type Cooling Towers Are Classified?

Last Answer : The dry type cooling towers are classified into two types ‘as follows: 1. Indirect dry type (or) Heller cooling system 2. Direct dry type-cooling system

Description : How Mechanical Draft Cooling Towers Are Classified?

Last Answer : Mechanical draft cooling tower is classified into three types: 1. Forced draft tower. 2. Induced draft counterflow tower. 3. Induced draft cross flow tower.

Description : How The Atmospheric (or) Natural Draught Cooling Towers Are Classified?

Last Answer : In atmospheric (or) natural cooling towers, the natural air provides the required cooling without the use of fans. This is classified into three types: 1. Natural draft spray filled towers. 2. Natural draft packed type towers. 3. Hyperbolic cooling towers.

Description : Name Different Types Of Cooling Towers?

Last Answer : The cooling towers are classified as follows. According to the construction of material: 1. Timber for small tower 2. Ferro concrete for large capacity stations. 3. Multi deck concrete towers for ... air draught: 1. Atmospheric (or) Natural draught cooling system 2. Mechanical draught cooling tower.

Description : What Is The Working Principle Of Cooling Towers?

Last Answer : The hot water is sprayed from the top of the tower, while the air is made to flow from the bottom of the tower to the top. This air cools the hot water in the cooling tower. Air evaporates ... and leaves at the top of the tower and cooled water leaves at the bottom and recirculated to the condenser.

Description : What Are The Advantages Of Hyperbolic Natural-draft Cooling Towers?

Last Answer :  Since no fans are used power cost and auxiliary equipments cost is reduced.  Hyperbolic tower chimney creates its own draft even when there is no wind.  Ground fogging and warm air re-circulation are avoided in hyperbolic towers.  The structure is more or less self-supported.

Description : Define Forced Draft And Induced Draft Cooling Towers?

Last Answer : If the fan is located at the bottom of the tower and air is blown by the fan up through the descending water it is called as forced draft cooling towers. If the fan is located at the top of the ... on the tower's side and drawn up and discharge through the fan casing, it is called as induced draft.

Description : In hyperboloid cooling towers the material is filled at 1. Tower’s bottom 2. Tower’s top 3. Near tower 4. None of above

Last Answer : Tower’s top

Description : How many times chlorination must be carried out for cooling towers 1. Twice a year 2. Once a year 3. Thrice a year 4. None of above

Last Answer : Twice a year

Description : Thermal efficiencies up to........have been observed in hybrid cooling towers a. 92 b. 82 c. 72 d. 62

Last Answer : 92

Description : . Improved cooling efficiency and minimum usage of material are the key features of ______ a. Natural draft cooling towers b. Cross flow towers c. Hyperbolic cooling d. All of above

Last Answer : Hyperbolic cooling

Description : . _____ type of cooling towers are used with nuclear power plants. a. Cross flow b. Natural draft c. Hyperbolic d. None of above

Last Answer : Hyperbolic