Why is induced draught considered better than the forced draught?
 a) Because power requirement is high for forced draught
b) Maintenance of induced draught fan is costlier
c) Forced draught is less efficient
d) Forced draught produces less amount of speed of air

1 Answer

Answer :

Because power requirement is high for forced draught

Related questions

Description : In a furnace employing forced draught as compared to induced draught, (A) Air is sucked in, so air leaks are more and hence the furnace efficiency is reduced (B) The fan operates hot and hence blades are liable to corrosion and erosion (C) Positive pressure exists in the furnace (D) None of these

Last Answer : (C) Positive pressure exists in the furnace

Description : Which of the following is used to produce draught in the locomotive boilers? (A) Chimney (B) Induced draught fan (C) Forced draught fan (D) Steam jet arrangement

Last Answer : Option D

Description : Power required in case of forced draught as compared to induced draught (for the same draught produced) is (A) Same (B) Less (C) More (D) Either more or less; depends on the flue gas density

Last Answer : (B) Less

Description : Ingress of cold air in the furnaces through cracks, charging doors, openings etc (A) Reduces the flue gas temperature and makes the furnace atmosphere oxidising (B) Increases the load on the induced draft fan (C) Reduces the furnace draught (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Define natural, mechanical, forced and induced draught systems.

Last Answer : Natural draught system: - When the fuel is burnt (combustion) in the furnace due to natural circulation of air, the draught is called natural draught. Mechanical draught system: -  In a mechanical ... combustion. OR If fan/blower is placed after the furnace then it is called as induced draught

Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Description : Which of the following accentuates clinkering trouble on furnace grate burning coal? (A) Low reactivity of carbonised residue containing high proportions of iron & sulphur (B) Low forced draught and fuel bed temperature (C) Thick fire bed and preheated primary air (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Flue gas from the heating chamber of byproduct coke ovens is removed by (A) Forced draft fan (B) Induced draft fan (C) Steam ejector (D) Natural draft

Last Answer : (D) Natural draft

Description : Differentiate induced draft and forced draft cooling towers based on (i) Location of fan (ii) Corrosion of blades (iii) Efficiency (iv) Fan size

Last Answer : Differentiate induced draft and forced draft cooling towers based on (i) Location of fan (ii) Corrosion of blades (iii) Efficiency (iv) Fan size

Description : Artificial draught produced by a fan in the furnace can be controlled by the (A) Speed of the fan (B) Damper (C) Variation in the pitch of fan blades (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Artificial draught produced by a fan can be controlled by the (A) Speed of the fan (B) Damper (C) Variation in the pitch of the fan blades (D) All (A), (B) and (C

Last Answer : (D) All (A), (B) and (C

Description : How does the flow of air occur in natural draught cooling towers? a) Natural pressure head density between cold outside air and humid inside air b) Variation in pressure of both cold outside air and ... given air vents and vacuum ports d) Because of difference in the volume of both the of airs

Last Answer : Natural pressure head density between cold outside air and humid inside air

Description : How does the flow of air occur in natural draught cooling towers? a) Natural pressure head density between cold outside air and humid inside air b) Variation in pressure of both cold outside air and ... given air vents and vacuum ports d) Because of difference in the volume of both the of airs

Last Answer : Natural pressure head density between cold outside air and humid inside air

Description : The most efficient cooling tower out of the following is (A) Induced draft (B) Forced draft (C) Natural draft (D) Atmospheric

Last Answer : (A) Induced draft

Description : Which one is not an induced draught furnace? (A) Blast furnace stove (B) Sintering furnace (C) High pressure boiler (D) None of these

Last Answer : (A) Blast furnace stove

Description : A convection process in which an external device, such as a fan, is used to produce the fluid flow.  a. Forced Convection  b. External Convection  c. Placid Convection  d. Thermionic Convection

Last Answer : Forced Convection

Description : What Are The Advantages Of Forced Draught System?

Last Answer :  Since the fan handles cold air, the fan size and the power required are less.  No need of water cooled bearings because the air being handled is cold air,  Pressure throughout the system is above atmospheric pressure so the air leakage into the furnace is reduced.

Description : Write About Forced Draught System?

Last Answer : In this system, the blower (forced draft fan) is located at the base of the boiler near the grate. Air is forced to the furnace by forced fan and the flue gases are forced to chimney through economizer and air preheater.

Description : Differentiate between natural draught and forced draught cooling tower.

Last Answer : Sr. No. Natural draught Forced draught 1 The air flows naturally without fan through tower and provides required cooling Fan is located at the top of the tower and enters the ... from tower cannot be controlled. The temp. of water coming out from tower can be controlled.

Description : Write the elements of forced draught cooling tower.

Last Answer : Following are the elements of forced draught cooling tower; a) Forced draught fan b) Eliminator c) Spray header d) Spray nozzle e) Circulating pump

Description : Power requirement of fans having constant wheel diameter varies __________ fan speed. (A) As square of (B) Directly as (C) As cube of (D) None of these

Last Answer : (C) As cube of

Description : . The pressure and power requirement of a gas fan at constant speed & capacity varies __________ the gas density. (A) Directly as (B) Inversely as square root of (C) Inversely as (D) As square of

Last Answer : (A) Directly as

Description : How The Induced Draught Is Working?

Last Answer : In an induced draught system, a blower (induced draft fan) is placed near (or) at the base of the chimney. The fan sucks the flue gas from the furnace creating a partial vacuum inside the ... aid the combustion of fuel. The flue gases drawn by the fan passes through chimney, to the atmosphere.

Description : Nickel-cadmium batteries are superior to lead-acid batteries at high discharge rates because they _______________. A. deliver a large amount of power and can be recharged in a shorter time B. need ... less mounting space C. have higher output voltages and require no maintenance D. all of the above

Last Answer : Answer: A

Description : How is air produced in mechanical draught cooling tower? a) Air Tuyeres b) Propeller fans c) Air blowers d) Louvre

Last Answer : Propeller fans

Description : The draught may be produced by a_________ a) Chimney b) Mechanical fan c) Steam jet d) All of the above

Last Answer : d) All of the above

Description : The draught in locomotive boilers is produced by a ___________ a) Chimney b) Centrifugal fan c) Steam jet d) All of the above

Last Answer : c) Steam jet

Description : The introduction of interpoles in between the main pole improves the performance of d.c. machines, because (A) The interpole produces additional flux to augment the developed torque. (B) The flux waveform is ... armature is removed. (D) A counter e.m.f. is induced in the coil undergoing commutation.

Last Answer : Ans: D Counter e.m.f is produced, it neutralizes the reactive emf.

Description : In India, are prefabricated components costlier than those of traditional cast-in-situ items that the prefabricated components replace? (A) Yes, because of heavier overheads and handling cost (B) Yes, ... of repetitive manufacture of a number of elements (D) No, because of savings in site labour

Last Answer : (C) No, because of repetitive manufacture of a number of elements

Description : Which of the following is the most important deterrents to an extended use of pulverised coal in boiler firing? (A) Ash disposal problem (B) Excessive fly-ash discharge from the stack (C) High power consumption in its transportation (D) Erosion of induced draft fan blades

Last Answer : (A) Ash disposal problem

Description : During summer, we feel comfortable under a fan because it (a) throws cool air on us (b) sets the air in motion, thereby increasing the evaporation of sweat (c) produces convection currents (d) produces air which carries heat away from the body

Last Answer : Ans:(b)

Description : During hot weather, the fan produces a feeling of comfort. This is because – (1) fan supplies cool air (2) fan cools the air (3) our perspiration evaporates rapidly (4) conductivity of air increases

Last Answer : (3) our perspiration evaporates rapidly Explanation: Fans make the air more comfortable for two reasons: (1) by moving the air, they blow away body heat and evaporate sweat, cooling the body, and (2) they also mix the cooler air near the floor with the warmer air by people's faces.

Description : During hot weather, the fan produces a feeling of comfort. This is because (1) fan supplies cool air (2) fan cools the air (3) our perspiration eva-porates rapidly (4) conductivity of air increases 

Last Answer : our perspiration eva-porates rapidly

Description : When the temperature and humidity of air is low, we usually use __________ draft cooling tower. (A) Natural (B) Forced (C) Induced (D) None of these

Last Answer : (A) Natural

Description : . A dilute aqueous solution is to be concentrated in an evaporator system. High pressure steam is available. Multiple effect evaporator system is employed, because (A) Total heat transfer area of ... in a single effect is much lower than that in any effect in a multi-effect system

Last Answer : (B) Total amount of vapor produced per Kg of feed steam in a multiple effect system is much higher than in a single effect

Description : State one requirement of an electron tube, which does not exist for semiconductors, that makes the tube less efficient than the semiconductor.

Last Answer : The electron tube requires filament or heater voltage, whereas the semiconductor device does not; consequently, no power input is spent by the semiconductor for conduction.

Description : Radiant Heaters More Energy Efficient Than Forced Air Heat?

Last Answer : Radiant heaters supply heat directly to the ceiling, floor or walls of a home. They use radiant heat transfer, which is heat moving directly from the hot surface to the objects or people in the room. ... lost in the duct work. Since there is no moving air, it is better for people with Allergies.

Description : The extent area under the command of draught animals is about …. a. 57%. c) 67% b. 78%. d) 89%

Last Answer : 57%

Description : The extent of area under the command of draught animals is about ..... a. 45%. c) 57% b. 75%. d) 64%

Last Answer : 57%

Description : . The extent of area under the command of draught animals is about a) 55% b) 54% c) 57% d) 60%

Last Answer : 57%

Description : The extant of area under the command of draught animals is about . A) 51% C) 50% B) 49% D) 57%

Last Answer : 51%

Description : In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : In which system is Cooling of hot water is done on tray as step by? a. Mechanical draught cooling system b. Hyperbolic cooling tower c. Atmospheric cooling tower d. Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : . In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : Which of the following is the most important deterrents to an extended use of pulverised coal in boiler firing? (A) Ash disposal problem (B) Excessive fly ash discharge from the stack (C) Higher power consumption in its transportation (D) Erosion of induced draft fan blades

Last Answer : (A) Ash disposal problem

Description : As compared to gravity dams, earthen dams (A) Are costlier (B) Are less susceptible to failure (C) Require sound rock foundations (D) Require less skilled labour

Last Answer : Answer: Option D

Description : Value-added services means _______________ 1. Giving full value for money 2. Better value for higher price 3. Additional service 4. Costlier service 5. All the above

Last Answer : Additional service

Description : Small labels can be found in appliances which usually a) Don‘t consume more energy c) don‘t have higher cost b) Don‘t consume less energy d) don‘t have high maintenance

Last Answer : Don‘t consume more energy

Description : Function of secondary air in pulverised coal firing is to (A) Transport the coal to the burner (B) Dry the coal (C) Ensure efficient burning of coal around the burner (D) Reduce primary air requirement

Last Answer : (C) Ensure efficient burning of coal around the burner

Description : Capacity & power requirement for an air compressor working at high altitude compared to sea-level will be (A) More (B) Less (C) Same (D) Either more or less; depends on the climatic conditions

Last Answer : (B) Less