When the temperature and humidity of air is low, we usually use
__________ draft cooling tower.
(A) Natural
(B) Forced
(C) Induced
(D) None of these

1 Answer

Answer :

(A) Natural

Related questions

Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Description : The most efficient cooling tower out of the following is (A) Induced draft (B) Forced draft (C) Natural draft (D) Atmospheric

Last Answer : (A) Induced draft

Description : Use of natural draft cooling tower is practised, when the air has low (A) Humidity (B) Temperature (C) Both 'a' & 'b' (D) Neither 'a' nor 'b'

Last Answer : (C) Both 'a' & 'b

Description : What Are The Advantages Of Induced Draft Cooling Tower Over Forced Draft Cooling Tower?

Last Answer : 1. The outlet water comes in contact with the driest air and warmest water comes in contact with most humid air. 2. The re-circulation is seldom a problem. 3. The first cost is low due to the reduction in pump power consumption.

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : The equipment frequently used for adiabatic humidification-cooling operation with recirculating liquid is (A) Natural draft cooling tower (B) Induced draft cooling tower (C) Spray chamber (D) None of these

Last Answer : (C) Spray chamber

Description : Pick out the wrong statement. (A) Different solids have different equilibrium moisture curves (B) Total condenser or reboiler is considered equivalent to one theoretical plate in McCabe-Thiele method of ... (D) Even a forced draft cooling tower cannot cool water below the wet bulb temperature

Last Answer : (C) Heat removal load on cooler remains constant, even with increase of the reflux ratio in a distillation column

Description : In natural draft cooling tower the air flow is obtained by___________ a) Difference in air pressure b) difference in air temperature c) Difference in air speed d) none of the above

Last Answer : Difference in air pressure

Description : Define Forced Draft And Induced Draft Cooling Towers?

Last Answer : If the fan is located at the bottom of the tower and air is blown by the fan up through the descending water it is called as forced draft cooling towers. If the fan is located at the top of the ... on the tower's side and drawn up and discharge through the fan casing, it is called as induced draft.

Description : Differentiate induced draft and forced draft cooling towers based on (i) Location of fan (ii) Corrosion of blades (iii) Efficiency (iv) Fan size

Last Answer : Differentiate induced draft and forced draft cooling towers based on (i) Location of fan (ii) Corrosion of blades (iii) Efficiency (iv) Fan size

Description : A natural draft cooling tower is filled with wooden grids, which covers about __________ percent of the tower height. (A) 10-15 (B) 30-40 (C) 70-80 (D) 90-100

Last Answer : (A) 10-15

Description : Explain the construction and working of induced draft cooling tower with neat sketch.

Last Answer : Induced draft cooling tower :  Diagram: Construction and working: Cooling towers are employed to cool utility cooling water by direct contact with air. The parts of a cooling tower are ... top pulls the hot air through the fills and cooled water gets collected in the cold water basin.

Description : Flue gas from the heating chamber of byproduct coke ovens is removed by (A) Forced draft fan (B) Induced draft fan (C) Steam ejector (D) Natural draft

Last Answer : (D) Natural draft

Description : Which among the following are the components of natural draft cooling tower a) Supply basin b) reinforced concrete c) Hot water distribution d) none of the above

Last Answer : reinforced concrete

Description : In the natural draft cooling tower_________ is not required a) Fan b) tower c) Nozzle d) none of the above

Last Answer : Fan

Description : Natural draft cooling tower are mainly used in a) Steel Industry b) Alumina industry c) Fertilizer industry d) Power station

Last Answer : Power station

Description : Natural draft in hyperbolic cooling tower is used for production of a) Fertilizer b) Steel c) Chemical d) Electrical energy

Last Answer : d) Electrical energy

Description : Design of hyperbolic cooling tower standard for all cooling tower a) Mechanical draft b) Natural draft c) Both a & b d) Neither a & b

Last Answer : b) Natural draft

Description : Factors affecting cooling of water in a cooling tower are: a. Temperature of air b. Humidity of air c. Temperature of hot air d. All of the above

Last Answer : Ans:- d. All of the above

Description : Differentiate between natural draught and forced draught cooling tower.

Last Answer : Sr. No. Natural draught Forced draught 1 The air flows naturally without fan through tower and provides required cooling Fan is located at the top of the tower and enters the ... from tower cannot be controlled. The temp. of water coming out from tower can be controlled.

Description : The cooling effect in a cooling tower cannot be increased by (A) Increasing the air velocity over the wet surfaces (B) Reducing the humidity of entering air (C) Lowering the barometric pressure (D) None of these

Last Answer : (D) None of these

Description : The cooling effect in a cooling tower can be speeded up by (A) Increasing the air velocity and area of exposed wet surface (B) Reducing the barometric pressure (C) Reducing the humidity of the air (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Which of the following accentuates clinkering troubles on furnace grate burning coal? (A) Low reactivity of carbonised residue containing high proportion of iron & sulphur (B) Low forced draft & fuel bed temperature (C) Thick firebed and preheated primary air (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Which of the following employs an accessory known as 'drift eliminator'? (A) Multiple effect evaporator (B) Mechanical draft cooling tower (C) Rotary dryer (D) Rotating disc contacto

Last Answer : (B) Mechanical draft cooling tower

Description : During dehumidification of unsaturated air wet bulb temperature & partial pressure of vapor are not constant. However, during evaporative cooling process with recirculated water supply, the __________ remains ... pressure of water vapor (C) Relative humidity (D) None of these

Last Answer : (A) Wet bulb temperature

Description : Moist air is cooled along the line of constant __________ , when it is passed over a cold & dry cooling coil, such that no condensation occurs? (A) Enthalpy (B) Relative humidity (C) Wet bulb temperature (D) Dew point temperature

Last Answer : (D) Dew point temperature

Description : __________ remains constant during the adiabatic cooling of moist air. (A) Wet bulb temperature (B) Dry bulb temperature (C) Relative humidity (D) Specific humidity

Last Answer : Option A

Description : The temperature of water cooled in cooling tower is always __________ temperature of entering air. (A) More than the wet bulb (B) Less than the wet bulb (C) Equal to the wet bulb (D) Equal to the dry bulb

Last Answer : (A) More than the wet bulb

Description : The minimum temperature to which the water can be cooled in a cooling tower is the __________ temperature of air. (A) Ambient (B) Dry bulb (C) Dew point (D) Wet bulb

Last Answer : C) Dew point

Description : Minimum temperature upto which water can be theoretically cooled down in the cooling tower by evaporative cooling is equal to the __________ temperature of air. (A) Wet bulb (B) Dry bulb (C) Saturation (D) Dew point

Last Answer : Option A

Description : Pick out the wrong statement. (A) With decrease in feed temperature, the number of plates required for binary distillation decreases for a given L/V' ratio (B) The extraction per unit ... and its cross￾section is wider at the bottom (D) Vander wall adsorption is also called chemisorption

Last Answer : (D) Vander wall adsorption is also called chemisorption

Description : Ingress of cold air in the furnaces through cracks, charging doors, openings etc (A) Reduces the flue gas temperature and makes the furnace atmosphere oxidising (B) Increases the load on the induced draft fan (C) Reduces the furnace draught (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Write the elements of forced draught cooling tower.

Last Answer : Following are the elements of forced draught cooling tower; a) Forced draught fan b) Eliminator c) Spray header d) Spray nozzle e) Circulating pump

Description : __________ Cooling towers have become the design standard for all natural-draft cooling towers because oftheir structural strength and minimum usage of material. • HCT • CCT • Hyperboloid • None

Last Answer : Hyperboloid

Description : Mode of heat transfer involved in the cooling of air cooled internal combustion engine is (A) Conduction (B) Natural convection (C) Forced convection (D) None of these

Last Answer : (B) Natural convection

Description : The main advantage of forced draft over natural draft is that (A) Combustion of fuel is complete (B) Smaller height chimney can be used (C) Furnace control is easier (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : The ……….-induced response of cooling tower is the key factor to improve safety and to reduce tower crack. a) wind c) heat b) water d) steam

Last Answer : wind

Description : Pick out the wrong statement (A) A horizontal line on the humidity chart indicates the temperature changes at constant molal humidity (B) When water is cooled from 80 to 70°C by exposure ... & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Last Answer : (D) Relative saturation of unsaturated mixture of water vapor & air cannot be increased by either reducing the mixture temperature or by increasing the total pressure

Description : Which of the following processes is followed by unsaturated air (with dry bulb temperature 12°C and relative humidity 47%) passing through water spray washer (temperature of water being constant at 40°C ... (B) Heating only (C) Both heating and humidification (D) Evaporative cooling

Last Answer : (C) Both heating and humidification

Description : The term "cooling range" in a cooling tower refers to the difference in the temperature of (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air (B) Hot water entering the ... air (C) Hot water entering the tower and the cooled water leaving the tower (D) None of these

Last Answer : (C) Hot water entering the tower and the cooled water leaving the tower

Description : Can a cooling tower cool water below the wet bulb temperature of inlet air? (A) Yes (B) No (C) Yes; but height of cooling tower will be prohibitively high (D) Yes; but the air flow rate should be excessively high

Last Answer : (B) No

Description : The term "approach" in a cooling tower refers to the difference in the temperature of the (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air (B ... (C) Hot water entering and the cooled water leaving the cooling tower (D) None of these

Last Answer : (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air

Description : Define natural, mechanical, forced and induced draught systems.

Last Answer : Natural draught system: - When the fuel is burnt (combustion) in the furnace due to natural circulation of air, the draught is called natural draught. Mechanical draught system: -  In a mechanical ... combustion. OR If fan/blower is placed after the furnace then it is called as induced draught

Description : In cooling tower ,higher temperature __________ corrosion potential • Decrease • Increase • Temperature has no effect on corrosion

Last Answer : Increase

Description : Induced draft fans provided in large thermal power plant boilers have __________ blades. (A) Forward curved (B) Backward curved (C) Double curved (D) Radial or straight

Last Answer : (B) Backward curved

Description : In a furnace employing forced draught as compared to induced draught, (A) Air is sucked in, so air leaks are more and hence the furnace efficiency is reduced (B) The fan operates hot and hence blades are liable to corrosion and erosion (C) Positive pressure exists in the furnace (D) None of these

Last Answer : (C) Positive pressure exists in the furnace

Description : What Are The Advantages Of Hyperbolic Natural-draft Cooling Towers?

Last Answer :  Since no fans are used power cost and auxiliary equipments cost is reduced.  Hyperbolic tower chimney creates its own draft even when there is no wind.  Ground fogging and warm air re-circulation are avoided in hyperbolic towers.  The structure is more or less self-supported.

Description : . Improved cooling efficiency and minimum usage of material are the key features of ______ a. Natural draft cooling towers b. Cross flow towers c. Hyperbolic cooling d. All of above

Last Answer : Hyperbolic cooling

Description : . _____ type of cooling towers are used with nuclear power plants. a. Cross flow b. Natural draft c. Hyperbolic d. None of above

Last Answer : Hyperbolic