The most efficient cooling tower out of the following is

(A) Induced draft

(B) Forced draft

(C) Natural draft

(D) Atmospheric

1 Answer

Answer :

(A) Induced draft

Related questions

Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Description : When the temperature and humidity of air is low, we usually use __________ draft cooling tower. (A) Natural (B) Forced (C) Induced (D) None of these

Last Answer : (A) Natural

Description : What Are The Advantages Of Induced Draft Cooling Tower Over Forced Draft Cooling Tower?

Last Answer : 1. The outlet water comes in contact with the driest air and warmest water comes in contact with most humid air. 2. The re-circulation is seldom a problem. 3. The first cost is low due to the reduction in pump power consumption.

Description : The equipment frequently used for adiabatic humidification-cooling operation with recirculating liquid is (A) Natural draft cooling tower (B) Induced draft cooling tower (C) Spray chamber (D) None of these

Last Answer : (C) Spray chamber

Description : Pick out the wrong statement. (A) Different solids have different equilibrium moisture curves (B) Total condenser or reboiler is considered equivalent to one theoretical plate in McCabe-Thiele method of ... (D) Even a forced draft cooling tower cannot cool water below the wet bulb temperature

Last Answer : (C) Heat removal load on cooler remains constant, even with increase of the reflux ratio in a distillation column

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : Define Forced Draft And Induced Draft Cooling Towers?

Last Answer : If the fan is located at the bottom of the tower and air is blown by the fan up through the descending water it is called as forced draft cooling towers. If the fan is located at the top of the ... on the tower's side and drawn up and discharge through the fan casing, it is called as induced draft.

Description : Differentiate induced draft and forced draft cooling towers based on (i) Location of fan (ii) Corrosion of blades (iii) Efficiency (iv) Fan size

Last Answer : Differentiate induced draft and forced draft cooling towers based on (i) Location of fan (ii) Corrosion of blades (iii) Efficiency (iv) Fan size

Description : Explain the construction and working of induced draft cooling tower with neat sketch.

Last Answer : Induced draft cooling tower :  Diagram: Construction and working: Cooling towers are employed to cool utility cooling water by direct contact with air. The parts of a cooling tower are ... top pulls the hot air through the fills and cooled water gets collected in the cold water basin.

Description : Flue gas from the heating chamber of byproduct coke ovens is removed by (A) Forced draft fan (B) Induced draft fan (C) Steam ejector (D) Natural draft

Last Answer : (D) Natural draft

Description : Use of natural draft cooling tower is practised, when the air has low (A) Humidity (B) Temperature (C) Both 'a' & 'b' (D) Neither 'a' nor 'b'

Last Answer : (C) Both 'a' & 'b

Description : A natural draft cooling tower is filled with wooden grids, which covers about __________ percent of the tower height. (A) 10-15 (B) 30-40 (C) 70-80 (D) 90-100

Last Answer : (A) 10-15

Description : Which among the following are the components of natural draft cooling tower a) Supply basin b) reinforced concrete c) Hot water distribution d) none of the above

Last Answer : reinforced concrete

Description : In the natural draft cooling tower_________ is not required a) Fan b) tower c) Nozzle d) none of the above

Last Answer : Fan

Description : In natural draft cooling tower the air flow is obtained by___________ a) Difference in air pressure b) difference in air temperature c) Difference in air speed d) none of the above

Last Answer : Difference in air pressure

Description : Natural draft cooling tower are mainly used in a) Steel Industry b) Alumina industry c) Fertilizer industry d) Power station

Last Answer : Power station

Description : Natural draft in hyperbolic cooling tower is used for production of a) Fertilizer b) Steel c) Chemical d) Electrical energy

Last Answer : d) Electrical energy

Description : Design of hyperbolic cooling tower standard for all cooling tower a) Mechanical draft b) Natural draft c) Both a & b d) Neither a & b

Last Answer : b) Natural draft

Description : Differentiate between natural draught and forced draught cooling tower.

Last Answer : Sr. No. Natural draught Forced draught 1 The air flows naturally without fan through tower and provides required cooling Fan is located at the top of the tower and enters the ... from tower cannot be controlled. The temp. of water coming out from tower can be controlled.

Description : Which of the following employs an accessory known as 'drift eliminator'? (A) Multiple effect evaporator (B) Mechanical draft cooling tower (C) Rotary dryer (D) Rotating disc contacto

Last Answer : (B) Mechanical draft cooling tower

Description : Write the elements of forced draught cooling tower.

Last Answer : Following are the elements of forced draught cooling tower; a) Forced draught fan b) Eliminator c) Spray header d) Spray nozzle e) Circulating pump

Description : The main advantage of forced draft over natural draft is that (A) Combustion of fuel is complete (B) Smaller height chimney can be used (C) Furnace control is easier (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : Heat transfer co-efficient equation for forced convection, Nu = 0.023 Re 0.8 . Pr n , is not valid, if the value of (A) n = 0.4 is used for heating (B) n = 0.3 is used for cooling (C) Reynolds number for the flow involved is > 10000 (D) Reynolds number for the flow involved is < 2100

Last Answer : (D) Reynolds number for the flow involved is < 2100

Description : The ……….-induced response of cooling tower is the key factor to improve safety and to reduce tower crack. a) wind c) heat b) water d) steam

Last Answer : wind

Description : Why is induced draught considered better than the forced draught? a) Because power requirement is high for forced draught b) Maintenance of induced draught fan is costlier c) Forced draught is less efficient d) Forced draught produces less amount of speed of air

Last Answer : Because power requirement is high for forced draught

Description : In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : In which system is Cooling of hot water is done on tray as step by? a. Mechanical draught cooling system b. Hyperbolic cooling tower c. Atmospheric cooling tower d. Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : . In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : Pick out the wrong statement. (A) With decrease in feed temperature, the number of plates required for binary distillation decreases for a given L/V' ratio (B) The extraction per unit ... and its cross￾section is wider at the bottom (D) Vander wall adsorption is also called chemisorption

Last Answer : (D) Vander wall adsorption is also called chemisorption

Description : Mode of heat transfer involved in the cooling of air cooled internal combustion engine is (A) Conduction (B) Natural convection (C) Forced convection (D) None of these

Last Answer : (B) Natural convection

Description : Process boilers with capacity of 2.5 MMBtu/h and above are also referred as _ a. Natural draft boilers b. Atmospheric boilers c. Both a. And b. d. None of the above

Last Answer : a. Natural draft boilers

Description : Define natural, mechanical, forced and induced draught systems.

Last Answer : Natural draught system: - When the fuel is burnt (combustion) in the furnace due to natural circulation of air, the draught is called natural draught. Mechanical draught system: -  In a mechanical ... combustion. OR If fan/blower is placed after the furnace then it is called as induced draught

Description : What Are The Advantages Of Hyperbolic Natural-draft Cooling Towers?

Last Answer :  Since no fans are used power cost and auxiliary equipments cost is reduced.  Hyperbolic tower chimney creates its own draft even when there is no wind.  Ground fogging and warm air re-circulation are avoided in hyperbolic towers.  The structure is more or less self-supported.

Description : . Improved cooling efficiency and minimum usage of material are the key features of ______ a. Natural draft cooling towers b. Cross flow towers c. Hyperbolic cooling d. All of above

Last Answer : Hyperbolic cooling

Description : . _____ type of cooling towers are used with nuclear power plants. a. Cross flow b. Natural draft c. Hyperbolic d. None of above

Last Answer : Hyperbolic

Description : Hyperbolic cooling towers are also referred as a. Natural draft towers b. Cross flow towers c. Hyperboloid towers d. None of the above

Last Answer : Hyperboloid towers

Description : Hyperbolic cooling towers have become design standard for all natural draft structural towers because usage of . a. Their structural strength b. Minimum usage of material. c. Improving cooling efficiency d. All of the above.

Last Answer : All of the above.

Description : Natural draft cooling towers are mainly used in the _____. • Steel industry • Fertilizer industry • Alumina industry • Power stations

Last Answer : Power stations

Description : __________ Cooling towers have become the design standard for all natural-draft cooling towers because oftheir structural strength and minimum usage of material. • HCT • CCT • Hyperboloid • None

Last Answer : Hyperboloid

Description : Natural draft in hyperbolic cooling towers reduces of fans a) Damage b) Efficiency c) Cost d) Speed

Last Answer : c) Cost

Description : Describe with neat sketch working of natural draft cooling towers.

Last Answer : Natural draft cooling tower: -In natural draught cooling tower, the circulation of air is produced by the pressure difference of air inside the tower and outside atmospheric air Hot cooling water falls down ... the pressure difference of air inside and outside of cooling tower (natural flow).

Description : Which of the following accentuates clinkering troubles on furnace grate burning coal? (A) Low reactivity of carbonised residue containing high proportion of iron & sulphur (B) Low forced draft & fuel bed temperature (C) Thick firebed and preheated primary air (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Which of the following is the most important deterrents to an extended use of pulverised coal in boiler firing? (A) Ash disposal problem (B) Excessive fly ash discharge from the stack (C) Higher power consumption in its transportation (D) Erosion of induced draft fan blades

Last Answer : (A) Ash disposal problem

Description : Ingress of cold air in the furnaces through cracks, charging doors, openings etc (A) Reduces the flue gas temperature and makes the furnace atmosphere oxidising (B) Increases the load on the induced draft fan (C) Reduces the furnace draught (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Which of the following is the most important deterrents to an extended use of pulverised coal in boiler firing? (A) Ash disposal problem (B) Excessive fly-ash discharge from the stack (C) High power consumption in its transportation (D) Erosion of induced draft fan blades

Last Answer : (A) Ash disposal problem

Description : How The Atmospheric (or) Natural Draught Cooling Towers Are Classified?

Last Answer : In atmospheric (or) natural cooling towers, the natural air provides the required cooling without the use of fans. This is classified into three types: 1. Natural draft spray filled towers. 2. Natural draft packed type towers. 3. Hyperbolic cooling towers.

Description : Coast Guard Regulations (46 CFR), require that an indicating light at the propulsion control station will operate if overloading or overheating occurs in a _______________. A. forced draft blower motor B. steering gear motor C. fuel pump motor D. condensate pump motor

Last Answer : Answer: B

Description : Universal motors will operate on AC or DC current, and are generally found in _____________. A. portable tools B. large pump motors C. turbo electric main motors D. forced draft fans

Last Answer : Answer: A

Description : An overload in which of the listed motors will result in the illumination of an indicating light at the propulsion control station alarm panel? A. Fuel pump motor B. Steering motor C. Condensate pump motor D. Forced draft blower motor

Last Answer : Answer: B