Write the elements of forced draught cooling tower.

1 Answer

Answer :

Following are the elements of forced draught cooling tower;

a) Forced draught fan

b) Eliminator

c) Spray header

d) Spray nozzle

e) Circulating pump

Related questions

Description : Differentiate between natural draught and forced draught cooling tower.

Last Answer : Sr. No. Natural draught Forced draught 1 The air flows naturally without fan through tower and provides required cooling Fan is located at the top of the tower and enters the ... from tower cannot be controlled. The temp. of water coming out from tower can be controlled.

Description : How is air produced in mechanical draught cooling tower? a) Air Tuyeres b) Propeller fans c) Air blowers d) Louvre

Last Answer : Propeller fans

Description : In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : In which system is Cooling of hot water is done on tray as step by? a. Mechanical draught cooling system b. Hyperbolic cooling tower c. Atmospheric cooling tower d. Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : . In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : How is air produced in mechanical draught cooling tower? A] Air Tuyeres. B] Propeller fans C] Air blowers. D] Louvre

Last Answer : B] Propeller fans

Description : When the temperature and humidity of air is low, we usually use __________ draft cooling tower. (A) Natural (B) Forced (C) Induced (D) None of these

Last Answer : (A) Natural

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : Pick out the wrong statement. (A) Different solids have different equilibrium moisture curves (B) Total condenser or reboiler is considered equivalent to one theoretical plate in McCabe-Thiele method of ... (D) Even a forced draft cooling tower cannot cool water below the wet bulb temperature

Last Answer : (C) Heat removal load on cooler remains constant, even with increase of the reflux ratio in a distillation column

Description : The most efficient cooling tower out of the following is (A) Induced draft (B) Forced draft (C) Natural draft (D) Atmospheric

Last Answer : (A) Induced draft

Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : What Are The Advantages Of Induced Draft Cooling Tower Over Forced Draft Cooling Tower?

Last Answer : 1. The outlet water comes in contact with the driest air and warmest water comes in contact with most humid air. 2. The re-circulation is seldom a problem. 3. The first cost is low due to the reduction in pump power consumption.

Description : Write About Forced Draught System?

Last Answer : In this system, the blower (forced draft fan) is located at the base of the boiler near the grate. Air is forced to the furnace by forced fan and the flue gases are forced to chimney through economizer and air preheater.

Description : Power required in case of forced draught as compared to induced draught (for the same draught produced) is (A) Same (B) Less (C) More (D) Either more or less; depends on the flue gas density

Last Answer : (B) Less

Description : In a furnace employing forced draught as compared to induced draught, (A) Air is sucked in, so air leaks are more and hence the furnace efficiency is reduced (B) The fan operates hot and hence blades are liable to corrosion and erosion (C) Positive pressure exists in the furnace (D) None of these

Last Answer : (C) Positive pressure exists in the furnace

Description : Which of the following accentuates clinkering trouble on furnace grate burning coal? (A) Low reactivity of carbonised residue containing high proportions of iron & sulphur (B) Low forced draught and fuel bed temperature (C) Thick fire bed and preheated primary air (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Which of the following is used to produce draught in the locomotive boilers? (A) Chimney (B) Induced draught fan (C) Forced draught fan (D) Steam jet arrangement

Last Answer : Option D

Description : What Are The Advantages Of Forced Draught System?

Last Answer :  Since the fan handles cold air, the fan size and the power required are less.  No need of water cooled bearings because the air being handled is cold air,  Pressure throughout the system is above atmospheric pressure so the air leakage into the furnace is reduced.

Description : Why is induced draught considered better than the forced draught? a) Because power requirement is high for forced draught b) Maintenance of induced draught fan is costlier c) Forced draught is less efficient d) Forced draught produces less amount of speed of air

Last Answer : Because power requirement is high for forced draught

Description : Define natural, mechanical, forced and induced draught systems.

Last Answer : Natural draught system: - When the fuel is burnt (combustion) in the furnace due to natural circulation of air, the draught is called natural draught. Mechanical draught system: -  In a mechanical ... combustion. OR If fan/blower is placed after the furnace then it is called as induced draught

Description : How The Atmospheric (or) Natural Draught Cooling Towers Are Classified?

Last Answer : In atmospheric (or) natural cooling towers, the natural air provides the required cooling without the use of fans. This is classified into three types: 1. Natural draft spray filled towers. 2. Natural draft packed type towers. 3. Hyperbolic cooling towers.

Description : How does the flow of air occur in natural draught cooling towers? a) Natural pressure head density between cold outside air and humid inside air b) Variation in pressure of both cold outside air and ... given air vents and vacuum ports d) Because of difference in the volume of both the of airs

Last Answer : Natural pressure head density between cold outside air and humid inside air

Description : How does the flow of air occur in natural draught cooling towers? a) Natural pressure head density between cold outside air and humid inside air b) Variation in pressure of both cold outside air and ... given air vents and vacuum ports d) Because of difference in the volume of both the of airs

Last Answer : Natural pressure head density between cold outside air and humid inside air

Description : Supercharging is the process of a. supplying the engine with air at a density greater than the density of the surrounding atmosphere b. providing forced cooling air c. injecting excess fuel d. raising the exhaust pressure

Last Answer : ANSWER a. supplying the engine with air at a density greater than the density of the surrounding atmosphere

Description : Scavenging air in diesel engine means a. air used for combustion under pressure b. forced air for cooling the cylinder c. burnt air containing products of combustion d. air used for forcing burnt gases out of the engines cylinder during the exhaust stroke

Last Answer : ANSWER d. air used for forcing burnt gases out of the engines cylinder during the exhaust stroke

Description : Mode of heat transfer involved in the cooling of air cooled internal combustion engine is (A) Conduction (B) Natural convection (C) Forced convection (D) None of these

Last Answer : (B) Natural convection

Description : Heat transfer co-efficient equation for forced convection, Nu = 0.023 Re 0.8 . Pr n , is not valid, if the value of (A) n = 0.4 is used for heating (B) n = 0.3 is used for cooling (C) Reynolds number for the flow involved is > 10000 (D) Reynolds number for the flow involved is < 2100

Last Answer : (D) Reynolds number for the flow involved is < 2100

Description : Define Forced Draft And Induced Draft Cooling Towers?

Last Answer : If the fan is located at the bottom of the tower and air is blown by the fan up through the descending water it is called as forced draft cooling towers. If the fan is located at the top of the ... on the tower's side and drawn up and discharge through the fan casing, it is called as induced draft.

Description : The current zero interruption, in oil and air blast circuit breakers, is achieved by (a) lengthening of the gap (b) cooling and blast effect (c) both (a) and (b) (d) deionizing the oil with forced air (e) none of the above

Last Answer : (c) both (a) and (b)

Description : A current density of _____ is ilsed for large power transformers with forced circulation of oil or with water cooling coils (a) 1.5 to 2.5 A/mm2 (b) 3.5 to 4.5 A/mm2 (c) 4.0 to 5.0 A/mm2 (d) 5.4 to 6.2 A/mm2

Last Answer : (d) 5.4 to 6.2 A/mm2

Description : Differentiate induced draft and forced draft cooling towers based on (i) Location of fan (ii) Corrosion of blades (iii) Efficiency (iv) Fan size

Last Answer : Differentiate induced draft and forced draft cooling towers based on (i) Location of fan (ii) Corrosion of blades (iii) Efficiency (iv) Fan size

Description : The cooling tower uses the phenomenon of evaporative cooling to cool warm water above the dbt of air. A. true B. false

Last Answer : ANSWER : B

Description : The equipment frequently used for adiabatic humidification-cooling operation with recirculating liquid is (A) Natural draft cooling tower (B) Induced draft cooling tower (C) Spray chamber (D) None of these

Last Answer : (C) Spray chamber

Description : Make up water is supplied during cooling tower operation to compensate for water losses due to (A) Evaporation (B) Blowdown (C) Entrainment (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : Heat load in a cooling tower (A) Means the amount of heat thrown away (KCal/hr.) by the cooling tower (B) Is equal to the number of kg, of water circulated times the cooling range (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : The term "cooling range" in a cooling tower refers to the difference in the temperature of (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air (B) Hot water entering the ... air (C) Hot water entering the tower and the cooled water leaving the tower (D) None of these

Last Answer : (C) Hot water entering the tower and the cooled water leaving the tower

Description : A packed tower compared to a plate tower for a particular mass transfer operation (A) Incurs smaller pressure drop (B) Allows installation of cooling coils (C) Is less costly when built in large sizes/diameters (D) Is more suitable, if suspended solids are present in fluid stream

Last Answer : (A) Incurs smaller pressure drop

Description : Make up water is required in a cooling tower to replace the water lost by (A) Evaporation (B) Drift (C) Blowdown and leakage (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Can a cooling tower cool water below the wet bulb temperature of inlet air? (A) Yes (B) No (C) Yes; but height of cooling tower will be prohibitively high (D) Yes; but the air flow rate should be excessively high

Last Answer : (B) No

Description : Drift in a cooling tower is (A) The water entrained by the circulating air (B) Dependent on the water lost by evaporation (C) Desirable (D) All (A), (B) & (C)

Last Answer : (A) The water entrained by the circulating air

Description : __________ number indicates the ratio of the rates of the heat and mass transfer incase of a cooling tower. (A) Sherwood (B) Stanton (C) Lewis (D) Peclet

Last Answer : (C) Lewis

Description : The term "approach" in a cooling tower refers to the difference in the temperature of the (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air (B ... (C) Hot water entering and the cooled water leaving the cooling tower (D) None of these

Last Answer : (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air

Description : Which of the following employs an accessory known as 'drift eliminator'? (A) Multiple effect evaporator (B) Mechanical draft cooling tower (C) Rotary dryer (D) Rotating disc contacto

Last Answer : (B) Mechanical draft cooling tower

Description : Use of natural draft cooling tower is practised, when the air has low (A) Humidity (B) Temperature (C) Both 'a' & 'b' (D) Neither 'a' nor 'b'

Last Answer : (C) Both 'a' & 'b

Description : The cooling effect in a cooling tower cannot be increased by (A) Increasing the air velocity over the wet surfaces (B) Reducing the humidity of entering air (C) Lowering the barometric pressure (D) None of these

Last Answer : (D) None of these

Description : The temperature of water cooled in cooling tower is always __________ temperature of entering air. (A) More than the wet bulb (B) Less than the wet bulb (C) Equal to the wet bulb (D) Equal to the dry bulb

Last Answer : (A) More than the wet bulb

Description : Blowdown in a cooling tower (A) Means discarding a small fraction of circulating water to prevent and limit the concentration of salt and impurities (B) Increases the scale forming tendencies of water (C) Is undesirable (D) All (A), (B) & (C)

Last Answer : (A) Means discarding a small fraction of circulating water to prevent and limit the concentration of salt and impurities

Description : A natural draft cooling tower is filled with wooden grids, which covers about __________ percent of the tower height. (A) 10-15 (B) 30-40 (C) 70-80 (D) 90-100

Last Answer : (A) 10-15

Description : The cooling effect in a cooling tower can be speeded up by (A) Increasing the air velocity and area of exposed wet surface (B) Reducing the barometric pressure (C) Reducing the humidity of the air (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)