The ratio of dissolved solids in circulating water to the dissolved solids in makeup water is called
a) Liquid gas ratio
b) Cycle of concentration
c) Cooling tower effectiveness
d) None of the above

1 Answer

Answer :

Cycle of concentration

Related questions

Description : The ratio of dissolved solids in circulating water to dissolved solids in makeup water is called. • Liquid gas ratio • Cycle of concentration • Cooling tower effectiveness • None of the above

Last Answer : Cycle of concentration

Description : Cooling tower effectiveness is the ratio of a) Range/( Range + approach) b) Approach/(range + approach) c) Range /(range - approach) d) Approach/ /(range - approach)

Last Answer : Range/( Range + approach)

Description : Cooling tower effectiveness is the ratio of _____. • Range/(range + approach) • Approach/(range + approach) • Range/ Approach • Approach/ Range

Last Answer : Range/(range + approach)

Description : Blowdown in a cooling tower (A) Means discarding a small fraction of circulating water to prevent and limit the concentration of salt and impurities (B) Increases the scale forming tendencies of water (C) Is undesirable (D) All (A), (B) & (C)

Last Answer : (A) Means discarding a small fraction of circulating water to prevent and limit the concentration of salt and impurities

Description : Pick out the wrong statement. (A) Different solids have different equilibrium moisture curves (B) Total condenser or reboiler is considered equivalent to one theoretical plate in McCabe-Thiele method of ... (D) Even a forced draft cooling tower cannot cool water below the wet bulb temperature

Last Answer : (C) Heat removal load on cooler remains constant, even with increase of the reflux ratio in a distillation column

Description : Drift in a cooling tower is (A) The water entrained by the circulating air (B) Dependent on the water lost by evaporation (C) Desirable (D) All (A), (B) & (C)

Last Answer : (A) The water entrained by the circulating air

Description : Pick out the wrong statement pertaining to the cooling towers. (A) In case of induced draft cooling tower, the fan is placed at the top of the tower (B) Effectiveness of ... Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Last Answer : (D) Effectiveness of a mechanical draft cooling tower is reduced with increase in air wet-bulb temperature

Description : What is a solution A. a solid dissolved in a gas B. a solute and a solvent C. a liquid dissolved in a gas D. an amalgam of solids, liquids, and gases?

Last Answer : B. A solute and a solvent

Description : Common applications of Cooling towers include a. Cooling the circulating water used in oil refineries b. petrochemical and other chemical plants c. thermal power stations d. All of the above.

Last Answer : All of the above.

Description : A packed tower compared to a plate tower for a particular mass transfer operation (A) Incurs smaller pressure drop (B) Allows installation of cooling coils (C) Is less costly when built in large sizes/diameters (D) Is more suitable, if suspended solids are present in fluid stream

Last Answer : (A) Incurs smaller pressure drop

Description : L/G ratio in a cooling tower is a ratio of _____. • Length and girth • Length and temperature gradient • Water flow rate and air mass flow rate • Air mass flow rate and water flow rate

Last Answer : Water flow rate and air mass flow rate

Description : The concentration of Total Dissolved Solids (TDS) in drinking water should not exceed (A) 500 mg/L (B) 400 mg/L (C) 300 mg/L (D) 200 mg/L

Last Answer : (A) 500 mg/L

Description : Pick out the wrong statement. (A) Recycled coarse material to the grinder by a classifier is termed as circulating load (B) Wear and tear in wet crushing is more than that in dry crushing of ... a pipeline which permits the solids to settle down due to reduction in velocity of the dust laden gas

Last Answer : (C) Size enlargement (opposite of size reduction) is not a mechanical operation

Description : is the measure of whether a plant is now using more or less energy to manufacture its product than it did in the past. a) Total Dissolved Solids (TDS). c) Plant Energy Performance (PEP) b) Revolutions Per Minute (RPM) d) Option (a) and (b)

Last Answer : Plant Energy Performance (PEP)

Description : is the measure of whether a plant is now using more or less energy to manufacture its product than it did in the past. a) Total Dissolved Solids (TDS) b) Plant Energy Performance (PEP) c) Revolutions Per Minute (RPM) d) Option (a) and (b)

Last Answer : Plant Energy Performance (PEP)

Description : Pick out the wrong statement. (A) Caustic embrittlement of boiler's metallic parts is caused by highconcentration of caustic soda in boiler feed water (B) Cooling and freezing of water kills the ... goes on decreasing (D) Dissolved oxygen content in high pressure boiler feed water should be nil

Last Answer : (B) Cooling and freezing of water kills the bacteria present in it

Description : Which among the following are the components of natural draft cooling tower a) Supply basin b) reinforced concrete c) Hot water distribution d) none of the above

Last Answer : reinforced concrete

Description : Which one of the following is true to estimate the range of cooling tower? a) Range = cooling water inlet temperature - wet bulb temperature b) Range = cooling water outlet temperature - wet bulb temperature ... = heat load in kcal per hour / water circulation in lines per hour d) None of the above

Last Answer : Range = heat load in kcal per hour / water circulation in lines per hour

Description : In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : Which of the following is the simplest method of cooling the condenser water? • Spray cooling pond • Cooling tower • Indirect air cooling • Hyperbolic cooling tower

Last Answer : Spray cooling pond

Description : In which system is Cooling of hot water is done on tray as step by? a. Mechanical draught cooling system b. Hyperbolic cooling tower c. Atmospheric cooling tower d. Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : The ……….-induced response of cooling tower is the key factor to improve safety and to reduce tower crack. a) wind c) heat b) water d) steam

Last Answer : wind

Description : . In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : In ________ cooling tower there is no direct contact between the water and Air. • Dry type • Evaporative type • Once through • All of the above

Last Answer : All of the above

Description : The pollutants that are present depend on __________ building material, as well. • Cooling tower • Water tower • Steam tower • Fire tower

Last Answer : cooling water

Description : How do you service a cooling tower? • Ensure Proper Airflow. . Clean Your Tubes. • Inspect the Water Pump. • All of above

Last Answer : all of above

Description : . How can we increase the efficiency of a cooling tower? a. Save energy. b. Reduce the amount of water being consumed. c. Decrease the amount of chemicals required for water treatment. d. All of above

Last Answer : All of above

Description : A ______ is a specialized heat exchanger in which air and water are brought into direct contact with each otherin order to reduce the water's temperature. a. Cooling tower b. Heating tower c. Both d. All are wrong

Last Answer : cooling tower

Description : How do you service a cooling tower? • Ensure Proper Airflow. Clean Your Tubes. • Inspect the Water Pump. • All of above

Last Answer : All of above

Description : How can we increase the efficiency of a cooling tower? a. Save energy. b. Reduce the amount of water being consumed. c. Decrease the amount of chemicals required for water treatment. d. All of above

Last Answer : d. All of above

Description : Pollution caused by cooling tower includes 1. Fouling 2. Limestone formation 3. Corrosion 4. All of above

Last Answer : All of above

Description : In hyperboloid cooling towers the material is filled at 1. Tower’s bottom 2. Tower’s top 3. Near tower 4. None of above

Last Answer : Tower’s top

Description : In the natural draft cooling tower_________ is not required a) Fan b) tower c) Nozzle d) none of the above

Last Answer : Fan

Description : In natural draft cooling tower the air flow is obtained by___________ a) Difference in air pressure b) difference in air temperature c) Difference in air speed d) none of the above

Last Answer : Difference in air pressure

Description : Cooling tower is a ______device a) Heat absorption b) heat rejection c) Both a and b c) neither a nor b

Last Answer : heat rejection

Description : Natural draft cooling tower are mainly used in a) Steel Industry b) Alumina industry c) Fertilizer industry d) Power station

Last Answer : Power station

Description : How is air produced in mechanical draught cooling tower? a) Air Tuyeres b) Propeller fans c) Air blowers d) Louvre

Last Answer : Propeller fans

Description : The first hyperbolic cooling tower was built in... a. 1916 b. 1917 c. 1918 d. 1919

Last Answer : 1918

Description : Normally the guaranteed best approach a cooling tower can achieve is _____. • 5°C • 12°C • 8°C • 2.8°C

Last Answer : 2.8°C

Description : A better indicators for cooling tower performance is _____. • Wet bulb temperature • Dry bulb temperature • Range • Approach

Last Answer : Approach

Description : Cooling efficiency of a cooling tower is significantly affected under cross-wind condition and might decrease to……… in the range of moderate to high wind velocity condition. a) 50% c) 25% b) 75% d) 90%

Last Answer : 75%

Description : The first hyperboloid shaped cooling tower was introduced by the Dutch engineers Frederik van Iterson andGerard Kuypers and built in ……….. a) 1918 c) 1919 b) 1870 d) 1920

Last Answer : 1918

Description : Which of the following faction affect the cooling tower performance? • The range • Heat load • Wet bulb temperature • All of the above

Last Answer : All of the above

Description : In cooling tower ,higher temperature __________ corrosion potential • Decrease • Increase • Temperature has no effect on corrosion

Last Answer : Increase

Description : When sizing a cooling tower the highest anticipate__________ should be used? • Dry bulb • Wet bulb • Both dry and wet bulb • None of the above

Last Answer : Wet bulb

Description : Carnot cycle efficiency depends upon  (a) properties of the medium/substance used  (b) condition of engine  (c) working condition  (d) temperature range of operation  (e) effectiveness of insulating material around the engine.

Last Answer : Answer : d

Description : Write various advantages of using high mast tower lighting viz a vIz Sodium lamps in circulating areas?

Last Answer : Ans. (i) Better illumination (ii) Vide area illumination (iii)where mass public movement (iv) Where loading & unloading of materials (v) At goods coaches & passenger coaches formation, checking and maintenance.

Description : The equipment frequently used for adiabatic humidification-cooling operation with recirculating liquid is (A) Natural draft cooling tower (B) Induced draft cooling tower (C) Spray chamber (D) None of these

Last Answer : (C) Spray chamber

Description : Water entrained by circulating air in cooling towers is termed as (A) Drift (B) Blow down (C) Vapor load (D) None of these

Last Answer : (A) Drift