Cooling tower is a ______device
a) Heat absorption b) heat rejection
c) Both a and b c) neither a nor b

1 Answer

Answer :

heat rejection

Related questions

Description : Heat load in a cooling tower (A) Means the amount of heat thrown away (KCal/hr.) by the cooling tower (B) Is equal to the number of kg, of water circulated times the cooling range (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : Noise produced by cooling fans (employed in air cooled heat exchangers or cooling tower) is mainly caused due to the turbulence created by blade passage through air. It can be reduced by use of a slower fan (A) With greater ... (B) Of increased diameter (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : Use of natural draft cooling tower is practised, when the air has low (A) Humidity (B) Temperature (C) Both 'a' & 'b' (D) Neither 'a' nor 'b'

Last Answer : (C) Both 'a' & 'b

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : In a packed absorption tower, if the equilibrium and operating lines are both straight lines, then the ratio, HETP/HTUOG __________ the absorption factor. (A) Increases with increase in (B) Is one at unity value of (C) Both (A) and (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) and (B)

Description : Which of the following is not a decree (a) Rejection of a plaint (b) Dismissal in default (c) Both (a) & (b) (d) Neither (a) nor (b)

Last Answer : (b) Dismissal in default

Description : A ______ is a specialized heat exchanger in which air and water are brought into direct contact with each otherin order to reduce the water's temperature. a. Cooling tower b. Heating tower c. Both d. All are wrong

Last Answer : cooling tower

Description : Which one of the following is true to estimate the range of cooling tower? a) Range = cooling water inlet temperature - wet bulb temperature b) Range = cooling water outlet temperature - wet bulb temperature ... = heat load in kcal per hour / water circulation in lines per hour d) None of the above

Last Answer : Range = heat load in kcal per hour / water circulation in lines per hour

Description : The ……….-induced response of cooling tower is the key factor to improve safety and to reduce tower crack. a) wind c) heat b) water d) steam

Last Answer : wind

Description : Which of the following faction affect the cooling tower performance? • The range • Heat load • Wet bulb temperature • All of the above

Last Answer : All of the above

Description : Design of hyperbolic cooling tower standard for all cooling tower a) Mechanical draft b) Natural draft c) Both a & b d) Neither a & b

Last Answer : b) Natural draft

Description : In a packed tower, the value of HETP equals HTUOG, when the equilibrium and the operating lines are (where, HETP = height equivalent to a theoretical plate HTUOG = overall gas phase height of a transfer unit). (A) Straight (B) Parallel (C) Both (A) & (B) (D) Neither (A) nor (B

Last Answer : (C) Both (A) & (B)

Description : When sizing a cooling tower the highest anticipate__________ should be used? • Dry bulb • Wet bulb • Both dry and wet bulb • None of the above

Last Answer : Wet bulb

Description : Energy can neither created nor destroyed. It can only change forms.  a. Conservation of Mass Principle  b. Conservation of Energy Principle  c. Conservation of Momentum Principle  d. Conservation of Heat Principle

Last Answer : Conservation of Energy Principle

Description : It states that mass is a commodity that can neither be heated nor destroyed with the exception of nuclear processes where the conversion of mass into energy is a fundamental principle  a. Law of ... Conservation of Energy  c. Law of Conservation of Power  d. Law of Conservation of Heat

Last Answer : Law of Conservation of Mass

Description : The first law of thermodynamics may be expressed in the following equivalent  a. the net heat transfer id equal to the network  b. the sum of the total energy forms leaving the system boundary is ... neither be created nor destroyed but only converted from one form to another  d. all of the above

Last Answer : all of the above

Description : In the absorption of ammonia in water, the main resistance to absorption is by the __________ phase. (A) Liquid (B) Gas (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (B) Gas

Description : Otto cycle efficiency is higher than Diesel cycle efficiency for the same compression ratio and heat input because in Otto cycle  A. combustion is at constant volume  B. expansion and compression are isentropic  C. maximum temperature is higher  D. heat rejection is lower

Last Answer : Answer: D

Description : During which of the following process does heat rejection takes place in Carnot cycle?  A. Isothermal expansion  B. Isentropic expansion  C. Isothermal compression  D. Isentropic compression

Last Answer : Answer: C

Description : Pollution caused by cooling tower includes 1. Fouling 2. Limestone formation 3. Corrosion 4. All of above

Last Answer : All of above

Description : In hyperboloid cooling towers the material is filled at 1. Tower’s bottom 2. Tower’s top 3. Near tower 4. None of above

Last Answer : Tower’s top

Description : Which among the following are the components of natural draft cooling tower a) Supply basin b) reinforced concrete c) Hot water distribution d) none of the above

Last Answer : reinforced concrete

Description : In the natural draft cooling tower_________ is not required a) Fan b) tower c) Nozzle d) none of the above

Last Answer : Fan

Description : In natural draft cooling tower the air flow is obtained by___________ a) Difference in air pressure b) difference in air temperature c) Difference in air speed d) none of the above

Last Answer : Difference in air pressure

Description : The ratio of dissolved solids in circulating water to the dissolved solids in makeup water is called a) Liquid gas ratio b) Cycle of concentration c) Cooling tower effectiveness d) None of the above

Last Answer : Cycle of concentration

Description : Cooling tower effectiveness is the ratio of a) Range/( Range + approach) b) Approach/(range + approach) c) Range /(range - approach) d) Approach/ /(range - approach)

Last Answer : Range/( Range + approach)

Description : Natural draft cooling tower are mainly used in a) Steel Industry b) Alumina industry c) Fertilizer industry d) Power station

Last Answer : Power station

Description : How is air produced in mechanical draught cooling tower? a) Air Tuyeres b) Propeller fans c) Air blowers d) Louvre

Last Answer : Propeller fans

Description : In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : Which of the following is the simplest method of cooling the condenser water? • Spray cooling pond • Cooling tower • Indirect air cooling • Hyperbolic cooling tower

Last Answer : Spray cooling pond

Description : In which system is Cooling of hot water is done on tray as step by? a. Mechanical draught cooling system b. Hyperbolic cooling tower c. Atmospheric cooling tower d. Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : The first hyperbolic cooling tower was built in... a. 1916 b. 1917 c. 1918 d. 1919

Last Answer : 1918

Description : Normally the guaranteed best approach a cooling tower can achieve is _____. • 5°C • 12°C • 8°C • 2.8°C

Last Answer : 2.8°C

Description : L/G ratio in a cooling tower is a ratio of _____. • Length and girth • Length and temperature gradient • Water flow rate and air mass flow rate • Air mass flow rate and water flow rate

Last Answer : Water flow rate and air mass flow rate

Description : The ratio of dissolved solids in circulating water to dissolved solids in makeup water is called. • Liquid gas ratio • Cycle of concentration • Cooling tower effectiveness • None of the above

Last Answer : Cycle of concentration

Description : Cooling tower effectiveness is the ratio of _____. • Range/(range + approach) • Approach/(range + approach) • Range/ Approach • Approach/ Range

Last Answer : Range/(range + approach)

Description : A better indicators for cooling tower performance is _____. • Wet bulb temperature • Dry bulb temperature • Range • Approach

Last Answer : Approach

Description : Cooling efficiency of a cooling tower is significantly affected under cross-wind condition and might decrease to……… in the range of moderate to high wind velocity condition. a) 50% c) 25% b) 75% d) 90%

Last Answer : 75%

Description : The first hyperboloid shaped cooling tower was introduced by the Dutch engineers Frederik van Iterson andGerard Kuypers and built in ……….. a) 1918 c) 1919 b) 1870 d) 1920

Last Answer : 1918

Description : . In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : In cooling tower ,higher temperature __________ corrosion potential • Decrease • Increase • Temperature has no effect on corrosion

Last Answer : Increase

Description : In ________ cooling tower there is no direct contact between the water and Air. • Dry type • Evaporative type • Once through • All of the above

Last Answer : All of the above

Description : The pollutants that are present depend on __________ building material, as well. • Cooling tower • Water tower • Steam tower • Fire tower

Last Answer : cooling water

Description : How do you service a cooling tower? • Ensure Proper Airflow. . Clean Your Tubes. • Inspect the Water Pump. • All of above

Last Answer : all of above

Description : . How can we increase the efficiency of a cooling tower? a. Save energy. b. Reduce the amount of water being consumed. c. Decrease the amount of chemicals required for water treatment. d. All of above

Last Answer : All of above

Description : How do you service a cooling tower? • Ensure Proper Airflow. Clean Your Tubes. • Inspect the Water Pump. • All of above

Last Answer : All of above

Description : How can we increase the efficiency of a cooling tower? a. Save energy. b. Reduce the amount of water being consumed. c. Decrease the amount of chemicals required for water treatment. d. All of above

Last Answer : d. All of above

Description : An add/drop multiplexer isa ______device. A) one-layer B) two-layer C) three-layer D) four-layer

Last Answer : three-layer

Description : STL file consists of which of the following format? a.ASCII b.Binary c.Both A & B d.Neither A nor B

Last Answer : c.Both A & B