L/G ratio in a cooling tower is a ratio of _____.
• Length and girth
• Length and temperature gradient
• Water flow rate and air mass flow rate
• Air mass flow rate and water flow rate

1 Answer

Answer :

Water flow rate and air mass flow rate

Related questions

Description : In natural draft cooling tower the air flow is obtained by___________ a) Difference in air pressure b) difference in air temperature c) Difference in air speed d) none of the above

Last Answer : Difference in air pressure

Description : Cooling tower effectiveness is the ratio of _____. • Range/(range + approach) • Approach/(range + approach) • Range/ Approach • Approach/ Range

Last Answer : Range/(range + approach)

Description : A better indicators for cooling tower performance is _____. • Wet bulb temperature • Dry bulb temperature • Range • Approach

Last Answer : Approach

Description : Can a cooling tower cool water below the wet bulb temperature of inlet air? (A) Yes (B) No (C) Yes; but height of cooling tower will be prohibitively high (D) Yes; but the air flow rate should be excessively high

Last Answer : (B) No

Description : A ______ is a specialized heat exchanger in which air and water are brought into direct contact with each otherin order to reduce the water's temperature. a. Cooling tower b. Heating tower c. Both d. All are wrong

Last Answer : cooling tower

Description : Normally the guaranteed best approach a cooling tower can achieve is _____. • 5°C • 12°C • 8°C • 2.8°C

Last Answer : 2.8°C

Description : The ratio of dissolved solids in circulating water to the dissolved solids in makeup water is called a) Liquid gas ratio b) Cycle of concentration c) Cooling tower effectiveness d) None of the above

Last Answer : Cycle of concentration

Description : The ratio of dissolved solids in circulating water to dissolved solids in makeup water is called. • Liquid gas ratio • Cycle of concentration • Cooling tower effectiveness • None of the above

Last Answer : Cycle of concentration

Description : Cooling tower effectiveness is the ratio of a) Range/( Range + approach) b) Approach/(range + approach) c) Range /(range - approach) d) Approach/ /(range - approach)

Last Answer : Range/( Range + approach)

Description : Which of the following is the simplest method of cooling the condenser water? • Spray cooling pond • Cooling tower • Indirect air cooling • Hyperbolic cooling tower

Last Answer : Spray cooling pond

Description : In ________ cooling tower there is no direct contact between the water and Air. • Dry type • Evaporative type • Once through • All of the above

Last Answer : All of the above

Description : Which one of the following is true to estimate the range of cooling tower? a) Range = cooling water inlet temperature - wet bulb temperature b) Range = cooling water outlet temperature - wet bulb temperature ... = heat load in kcal per hour / water circulation in lines per hour d) None of the above

Last Answer : Range = heat load in kcal per hour / water circulation in lines per hour

Description : How is air produced in mechanical draught cooling tower? a) Air Tuyeres b) Propeller fans c) Air blowers d) Louvre

Last Answer : Propeller fans

Description : Which of the following faction affect the cooling tower performance? • The range • Heat load • Wet bulb temperature • All of the above

Last Answer : All of the above

Description : In cooling tower ,higher temperature __________ corrosion potential • Decrease • Increase • Temperature has no effect on corrosion

Last Answer : Increase

Description : __________ number indicates the ratio of the rates of the heat and mass transfer incase of a cooling tower. (A) Sherwood (B) Stanton (C) Lewis (D) Peclet

Last Answer : (C) Lewis

Description : What is the reason to service a cooling tower? a) to ensure proper air flow b) to clean the tubes c) to inspect the water pump d) all of these

Last Answer : all of these

Description : Pick out the wrong statement. (A) Different solids have different equilibrium moisture curves (B) Total condenser or reboiler is considered equivalent to one theoretical plate in McCabe-Thiele method of ... (D) Even a forced draft cooling tower cannot cool water below the wet bulb temperature

Last Answer : (C) Heat removal load on cooler remains constant, even with increase of the reflux ratio in a distillation column

Description : . _____ type of cooling towers are used with nuclear power plants. a. Cross flow b. Natural draft c. Hyperbolic d. None of above

Last Answer : Hyperbolic

Description : Which among the following are the components of natural draft cooling tower a) Supply basin b) reinforced concrete c) Hot water distribution d) none of the above

Last Answer : reinforced concrete

Description : In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : In which system is Cooling of hot water is done on tray as step by? a. Mechanical draught cooling system b. Hyperbolic cooling tower c. Atmospheric cooling tower d. Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : The ……….-induced response of cooling tower is the key factor to improve safety and to reduce tower crack. a) wind c) heat b) water d) steam

Last Answer : wind

Description : . In which system is Cooling of hot water is done on tray as step by? a) Mechanical draught cooling system b) Hyperbolic cooling tower c) Atmospheric cooling tower d) Wet cooling tower

Last Answer : Atmospheric cooling tower

Description : The pollutants that are present depend on __________ building material, as well. • Cooling tower • Water tower • Steam tower • Fire tower

Last Answer : cooling water

Description : How do you service a cooling tower? • Ensure Proper Airflow. . Clean Your Tubes. • Inspect the Water Pump. • All of above

Last Answer : all of above

Description : . How can we increase the efficiency of a cooling tower? a. Save energy. b. Reduce the amount of water being consumed. c. Decrease the amount of chemicals required for water treatment. d. All of above

Last Answer : All of above

Description : How do you service a cooling tower? • Ensure Proper Airflow. Clean Your Tubes. • Inspect the Water Pump. • All of above

Last Answer : All of above

Description : How can we increase the efficiency of a cooling tower? a. Save energy. b. Reduce the amount of water being consumed. c. Decrease the amount of chemicals required for water treatment. d. All of above

Last Answer : d. All of above

Description : The term "cooling range" in a cooling tower refers to the difference in the temperature of (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air (B) Hot water entering the ... air (C) Hot water entering the tower and the cooled water leaving the tower (D) None of these

Last Answer : (C) Hot water entering the tower and the cooled water leaving the tower

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : The term "approach" in a cooling tower refers to the difference in the temperature of the (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air (B ... (C) Hot water entering and the cooled water leaving the cooling tower (D) None of these

Last Answer : (A) Cold water leaving the tower and the wet bulb temperature of the surrounding air

Description : The temperature of water cooled in cooling tower is always __________ temperature of entering air. (A) More than the wet bulb (B) Less than the wet bulb (C) Equal to the wet bulb (D) Equal to the dry bulb

Last Answer : (A) More than the wet bulb

Description : The minimum temperature to which the water can be cooled in a cooling tower is the __________ temperature of air. (A) Ambient (B) Dry bulb (C) Dew point (D) Wet bulb

Last Answer : C) Dew point

Description : In a forced draft cooling tower, water is cooled from 95 to 80°F by exposure to air with a wet bulb temperature of 70°F. In this case, the (A) Range is 15°F (B) Approach is 10°F (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : Minimum temperature upto which water can be theoretically cooled down in the cooling tower by evaporative cooling is equal to the __________ temperature of air. (A) Wet bulb (B) Dry bulb (C) Saturation (D) Dew point

Last Answer : Option A

Description : Factors affecting cooling of water in a cooling tower are: a. Temperature of air b. Humidity of air c. Temperature of hot air d. All of the above

Last Answer : Ans:- d. All of the above

Description : Pollution caused by cooling tower includes 1. Fouling 2. Limestone formation 3. Corrosion 4. All of above

Last Answer : All of above

Description : In hyperboloid cooling towers the material is filled at 1. Tower’s bottom 2. Tower’s top 3. Near tower 4. None of above

Last Answer : Tower’s top

Description : In the natural draft cooling tower_________ is not required a) Fan b) tower c) Nozzle d) none of the above

Last Answer : Fan

Description : Cooling tower is a ______device a) Heat absorption b) heat rejection c) Both a and b c) neither a nor b

Last Answer : heat rejection

Description : Natural draft cooling tower are mainly used in a) Steel Industry b) Alumina industry c) Fertilizer industry d) Power station

Last Answer : Power station

Description : The first hyperbolic cooling tower was built in... a. 1916 b. 1917 c. 1918 d. 1919

Last Answer : 1918

Description : Cooling efficiency of a cooling tower is significantly affected under cross-wind condition and might decrease to……… in the range of moderate to high wind velocity condition. a) 50% c) 25% b) 75% d) 90%

Last Answer : 75%

Description : The first hyperboloid shaped cooling tower was introduced by the Dutch engineers Frederik van Iterson andGerard Kuypers and built in ……….. a) 1918 c) 1919 b) 1870 d) 1920

Last Answer : 1918

Description : When sizing a cooling tower the highest anticipate__________ should be used? • Dry bulb • Wet bulb • Both dry and wet bulb • None of the above

Last Answer : Wet bulb

Description : The seepage exit gradient in a soil is the ratio of A) Total head to the length of seepage (B) Flow line to slope (C) Head upstream to that at downstream (D) Head loss to the length of the seepage

Last Answer : Answer: Option D

Description : Pick out the wrong statement. (A) The Reynolds analogy for mass transfer is given by Lewis relation and is applicable, when Schmidt number is one (B) Sherwood number for flow in pipes can be expressed ... flux of a component A in binary mixture of A and B is given by - Dab'.dCA/dz

Last Answer : (C) According to film theory for equimolar counter diffusion, the mass transfer coefficient is given by DAB(B)P - 3, Q - 2

Description : For the same heat load and mass flow rate in the tube side of a shell and tube heat exchanger, one may use multipass on the tube side, because it (A) Decreases the pressure drop (B) ... the outlet temperature of cooling medium (C) Increases the overall heat transfer coefficient (D) None of these

Last Answer : (C) Increases the overall heat transfer coefficient