What are the protections for GENERATOR TRANSFORMER?  

1 Answer

Answer :

a) Differential protection

b) Restricted earthfault protection

c) Backup earthfault protection

d) GT phase back up protection

e) Overfluxing protection

f) Oil surge (gas) protection

g) High winding temperature and oil temperature protection. 

Related questions

Description : What are the different Generator Protections employed in Thermal Power Plants?

Last Answer : Answer: Faults in the windings, Over load protection, Over heating of windings or bearings, Over speed protection, Loss of Excitation protection, Motoring operation protection, Inadvertent ... , out of step operation protection, sub-synchronous oscillations protection and earth fault protection

Description : What are the different Generator Protections employed in Thermal Power Plants?

Last Answer : Faults in the windings, Over load protection, Over heating of windings or bearings, Over speed protection, Loss of Excitation protection, Motoring operation protection, Inadvertent energisation ... , out of step operation protection, sub-synchronous oscillations protection and earth fault protection

Description : What are the working principles of generator main protections?

Last Answer : GENERATOR START UP PROTECTIONS SUPPLEMENTARY PROTECTION OF GENERATOR The generator is normally expected to run rated speed before excitation power is applied by closing the field breaker. ... position to ensure that the protection is inoperable when the machine is connected to grid.  

Description : What are the protections provided for DG?

Last Answer : 1. Differential protection (87). 2. Over speed of engine. 3. Reverse power protection (in LOCA condition time delay). 4. Low lubricating oil pressure. 5. Cooling water temperature high. 6. 6 ... 8. Emergency stops push button. In LOCA condition 4 - 8 protections are not permitted to operate. 

Description : What are the protections used in 415 V Class II side?

Last Answer : LV to UPS 1. CTZM 2. 50 (instantaneous over current) 3. short circuit UPS to PMCC S & T 1. 51 RYB (inverse over current) 2. 27 (under voltage) 3. 51N (earth fault) From Class III to Class II tie CTZM at Class III and 51, 51N at Class II. 

Description : What are the protections used in Class III & Class IV 415 V LV side?  

Last Answer : Class III 415 V LV side 1. 51 (inverse over current) 2. 50 (instantaneous over current) 3. 27 (under voltage) 4. 51N (earth fault) 5. 64 (REF)  Class IV 415 V LV side 1. 51 RYB (inverse over current) 2. 51N (earth fault) 

Description : What are the protections provided in charger?  

Last Answer : 1. Over load (49). 2. Over voltage (59). 3. Short-circuit (3250 Amps). 4. Phase sequence and phase fail. 5. di/dt and dv/dt protection. 

Description : What are the protections adopted in UPS or PMCC supply?

Last Answer : LV (incomer) or UPS input CTZM, Over current, Short circuit protections PMCC S or T input or UPS output Under voltage (27), 51RYB, 51N protections. 

Description : What are the protections are there for lines?  

Last Answer : Directional earthfault protection Directional over current protection Local breaker back up protection Pole discrepancy Main protection (distance protection)

Description : What are the protections are there for BUSBAR?

Last Answer : Instantaneous over current protection Bus bar differential protection Local breaker back up protection 

Description : What are the in-built protections provided in MCC cell? 

Last Answer : Fuses for short circuit protection. OLR for over load and single phasing protection. Electrical and Mechanical interlock in valve cell against short circuit. 

Description : What are the protections provided in PMCC circuit breakers?

Last Answer : 1. IDMT O/C (CDG 34). 2. IDMT E/F (CDG 11).  3. Under voltage (40% of 110V). 

Description : What are the protections provided for motor feeder?  

Last Answer : Ith - Thermal over load I2S - Unbalance load I0S - Earth fault protection I1t - Stalling protection I1Inst. - Short circuit protection 

Description : What are the protections for UT?  

Last Answer : a) Differential protection b) LV restricted earthfault protection c) LV back up earthfault and over current protection d) Buchholz and high oil, winding temperature protection. 

Description : What are the protections for SUT? 

Last Answer : a) Over current protection for phase and earth fault b) Differential protection c) HV and LV restricted earthfault protection  d) HV side directional back up over current protection for phase ... protection f) Over fluxing protection g) Buchholz and high oil, winding temperature protection. 

Description : What are the built in protections for transformers?

Last Answer : a) Buchholz relay b) Explosion vent or relief valve c) Gas operated relay for on load tap changers. 

Description : Why all 415V transformers are chosen Dyn 11? What are the protections provided for the 415V transformers?

Last Answer : a) To facilitate interchange. b) To have momentary parallel during changeover. Protections a) Door interlock to trip HT and LT breakers. b) LT breaker can on only after HT breaker is in on position. c) ... and restricted E/F (51N + 64). f) Winding temp high trip (140°C trip and 130°C alarm) 

Description : What are the built in protections provided in 415 V breaker?  

Last Answer : a. DINF (making current magnetic release) This consists of a laminated magnetic circuit. This is placed under the lower current terminal pole. This is provided for all the three poles. It has a core that rotates ... by a lever. It is placed in front of the breaker. Setting range is 60% to 100%.  

Description : What are the protections provided for 220 kV lines and bus bars? 

Last Answer : a. Bus bar differential protection. b. Distance protection. c. Over current protection. d. Earth fault protection. 

Description : The electrical schematic illustrated in figure A, depicts a/an _____________. EL-0059 A. autotransformer B. Delta Wye transformer C. primary EMF generator D. potential transformer

Last Answer : Answer: D

Description : Which of the listed electrical devices is represented by the symbol shown in the illustration? EL-0055 A. Fixed resistance resistor B. Coil with magnetic core C. DC motor or generator shunt field D. Transformer

Last Answer : Answer: D

Description : When used for taking resistance measurements, a volt-ohm-milliammeter is normally powered by _____________. A. a hand cranked generator B. internal storage batteries C. the current in the circuit being tested D. a step down transformer

Last Answer : Answer: B

Description : How Generator Transformer is cooled in Thermal Power Plant?

Last Answer : Answer: MVA power rating of the Generator Transformer will be equal to the alternator. Hence lot of heat will be generated while generator transformer is under operation. Oil Forced Air Forced (OFAF) type of cooling is employed for generator transformer

Description : How Generator Transformer is cooled in Thermal Power Plant?

Last Answer : MVA power rating of the Generator Transformer will be equal to the alternator. Hence lot of heat will be generated while generator transformer is under operation. Oil Forced Air Forced (OFAF) type of cooling is employed for generator transformer

Description : Why the earthing transformer primary voltage is 16.5 kV rated in main generator even though actual voltage during the E/F is root 3 times less?

Last Answer : The transformer should not saturate during E/F otherwise it will cause ferroresonance with the GT winding capacitance. Dangerous O/V and neutral shifting will occur. During loss of load or field ... saturation. Saturation can also occur due to point on wave of application causing flux doubling. 

Description : Why are children considered deserving of protections that other weak or powerless individuals do not get?

Last Answer : We do have protections in place. Every state has an Adult Protective Services division and that people are allowed to file bankruptcy rather than be held totally responsible for their debts is a form of protecting ... 't we can only protect them so far and so much and then they are on their own.

Description : What store sells laptop protections?

Last Answer : Best Buy would have laptop protectors. And yes it would be a good investment to buy one for your laptop. It will protect your laptop from getting scratched or dinged from being dropped.

Description : How are circuits protections devices connected to the circuit they are intended to protect and why are they connected in this way?

Last Answer : In series, so total current will be stopped when the device opens.

Description : State the types of protections provided by MCB. 

Last Answer : The types of protections provided by MCB: 1. MCB provides short circuit protection. 2. MCB provides overload protection

Description : A transformer works on the principle of – (1) Self induction (2) Mutual induction (3) Generator (4) Inverter

Last Answer : (2) Mutual induction

Description : A device that converts mechanical energy into electric energy is called----? A. Motor. B. Transformer. C. Coil. D. Generator?

Last Answer : B. Transformer.

Description : The Faraday’s law states about which type of EMF? a) Transformer EMF b) Back EMF c) Generator EMF d) Secondary EMF

Last Answer : a) Transformer EMF

Description : Overfluxing protection is recommended for (a) distribution transformer (b) generator transformer of the power plant (c) auto-transformer of the power plant (d) station transformer of the power plant

Last Answer : (b) generator transformer of the power plant

Description : Wave trap is used to trap waves of (a) power frequencies (b) higher frequencies entering generator or transformer units (c) either of the above (d) none of the above

Last Answer : (b) higher frequencies entering generator or transformer units

Description : Which of the following converts electric energy into mechanical energy: a. Transformer b. DC generator c. Motor d. AC generator

Last Answer : d. AC generato

Description : The most common source of AC voltage is: a. motor b. generator c. cell d. transformer

Last Answer : c. cell

Description : A transformer works on the principle of (1) Self induction (2) Mutual induction (3) Generator (4) Inverter

Last Answer : Mutual induction

Description : A generator is connected through a 20 MVA, 13.8/138 kV step down transformer, to a transmission line. At the receiving end of the line a load is supplied through a step down transformer of 10 MVA, 138/69 kV rating. A 0.72 ... load (in per unit) in generator will be (A) 36 (B) 1.44 (C) 0.72 (D) 0.18

Last Answer : A generator is connected through a 20 MVA, 13.8/138 kV step down transformer, to a transmission line. At the receiving end of the line a load is supplied through a step down transformer of 10 MVA, 138/ ... MVA and 69 kV in load circuit, the value of the load (in per unit) in generator will be 36 

Description : Induction generator is self excited machine. a) True b) False

Last Answer : Ans: B

Description : Voltage build up in an isolated induction generator depends on A. Capacitor bank value B. Residual magnetism of the rotor iron C. Residual magnetism of the stator iron a) A, B b) A, B, C c) B d) A, C

Last Answer : Ans: A

Description : If the residual flux is absent in the rotor iron of the isolated induction generator, a) it will not run. b) it will run as induction motor c) it will burn the winding d) it will not affect the characteristic of the generator

Last Answer : Ans: A

Description : Induction generator a) can not work in isolation b) can work in isolation c) should work in parallel with synchronous generators d) any of the mentioned

Last Answer : Ans: C

Description : According to Coast Guard Regulation (46 CFR) for emergency power and lighting systems, which of the listed items is the only permissible starting aid for the emergency diesel generator engine? A. Ether B. Lube oil heater C. Jacket water heater D. Fuel oil heater

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR) require that each alternating current generator arranged for parallel operation shall be provided with _____________. A. more than one means of excitation B. individual circuit fuses C. a high back-pressure trip D. a reverse-power trip

Last Answer : Answer: D

Description : An emergency generator, driven by an internal combustion engine, shall be tested under load for a minimum of 2 hours at least once every _____________. A. week B. 2 weeks C. month D. 3 months

Last Answer : Answer: C

Description : Coast Guard Regulations (46 CFR) require that the emergency diesel generator engine shut down when _____________. A. lubricating oil pressure is lost B. the engine overspeeds dangerously C. fixed CO2 is released into the emergency diesel generator space D. all of the above

Last Answer : Answer: D

Description : The shipboard general alarm system must receive its main source of power from _____________. A. a storage battery B. the emergency generator C. an auxiliary generator D. the ship's service generator

Last Answer : Answer: A