What are the causes of motor failure? 

1 Answer

Answer :

a. Corrosion or rust.

b. Excessive moisture (winding IR low and bearing lubrication loss).

c. High ambient temperature.

d. Poor ventilation.

e. Inadequate lubrication.

f. Misalignment.

g. Oil and dirt.

h. Excessive starts and repetitive surges.

i. Persistent over loads.

j. Shaft currents (bearing pitting).

k. Mis application.

l. Manufacture defect or wrong design.

m. Deterioration with age.

n. Maintenance improper. 


Related questions

Description : Where automatic restart does not present a hazard after a power failure, Coast Guard Regulations (46 CFR) require motor controllers for auxiliaries vital to the propelling equipment to be provided ... overload protection B. low voltage protection C. low voltage release D. reverse current protection

Last Answer : Answer: C

Description : When power is restored after a complete power failure, a steering gear pump motor will ____________. A. have to be restarted B. have to be reset C. restart automatically D. trip its overload relays

Last Answer : Answer: C

Description : What are the causes of failure of bearings?

Last Answer : a) Faulty mounting b) Faulty lubrication c) Foreign matter in lubrication d) Water in the bearing arrangement e) Vibration f) Inoccurrences of form of shaft or housing seating. g) Passage of electric current. h) Metal fatigue

Description : A synchronous motor maintains synchronism with the rotating field because _____________. A. field strength varies directly with rotor slip B. DC current applied to the rotor coils causes the rotor ... the flux created by the excitation current D. the stator flux rotates in the opposite direction

Last Answer : Answer: B

Description : What are the causes for motor unbalance current?

Last Answer : a) Loose connection b) Voltage unbalance c) Turns short circuit 

Description : What are the causes for motor high current?

Last Answer : a) High frequency (51 Hz - 105% current) b) Low frequency (48 Hz – 102% current) c) High voltage d) Low voltage e) Mechanical over load 

Description : What are the causes of motor vibration? 

Last Answer : a) Broken rotor. b) Slacked stator core. c) Slacked rotor core. d) Rotor winding unbalance. 

Description : Upon failure of the normal power supply, the emergency generator is placed on the line by the _____________. A. bus tie feeder B. automatic bus transfer device C. line connection feeder D. power failure alarm bus

Last Answer : Answer: B

Description : Voltage failure of an AC generator may be caused by ____________. A. failure of the exciter generator B. a tripped bus circuit breaker C. high mica segments on the stator bus bar D. excessive prime mover speed

Last Answer : Answer: A

Description : If an AC generator experiences voltage failure, the cause may be _____________. A. an open in the field circuit B. the brushes shifting out of the neutral plane C. excessive locked-rotor current D. a rotating slip ring

Last Answer : Answer: A

Description : An alternator will fail to produce line voltage as a result of _____________. A. a closed circuit breaker B. oxidized slip rings C. improperly staggered brushes D. exciter generator failure

Last Answer : Answer: D

Description : Unnecessary and frequent applications of varnish to the generator windings to repair defective insulation will result in ____________. A. heavy coatings of varnish interfering with heat dissipation B. ... of the rectifier assembly D. a built-up of varnish without changing generator operation

Last Answer : Answer: A

Description : In the event of a power failure during cargo loading operations, the movement of an electric powered cargo winch will be stopped by ____________. A. a manual override switch B. the weight of the load on the boom C. a spring set brake D. a hand operated band brake

Last Answer : Answer: C

Description : The failure of ball bearings used in electric motors can result from _____________. A. failure to clean the bearing before repacking B. failure to maintain proper alignment C. excess lubrication forcing the bearing full of grease and eliminating all areas of expansion D. all of the above

Last Answer : Answer: D

Description : Which of the following conditions can lead to the failure of a resistor? A. Excessive vibration B. Insufficient ventilation C. Corrosion D. All of the above

Last Answer : Answer: D

Description : When insulation failure produces a low resistance current path between two conductors, the resulting condition is known as ____________. A. an open B. a short circuit C. a ground D. a surge

Last Answer : Answer: B

Description : The 24 volt DC bus on the emergency switchboard is used to supply power to the _____________. A. general alarm system B. gyrocompass power failure alarm system C. smoke detection system D. all of the above

Last Answer : Answer: D

Description : Upon failure of the normal power supply, the emergency generator is placed on the line by the _____________. A. main bus tie feeder B. automatic bus transfer device C. line connection feeder D. power failure alarm bus

Last Answer : Answer: B

Description : Humming or buzzing of electric contacts is a symptom of ____________. A. low voltage on the operating coil B. power failure to the operating coil C. a control circuit ground D. a control circuit overload

Last Answer : Answer: A

Description : If both the 'high level' and 'low level' alarms come on for the same address of a centralized control console, the most likely problem is a/an ____________. A. sensor failure B. failed alarm C. low level D. extremely high level

Last Answer : Answer: A

Description : The type of control circuit that will not permit automatic restarting after power is restored, following a power failure is called _____________. A. low voltage protection B. low voltage release C. overload lockout D. reduced voltage restart

Last Answer : Answer: A

Description : The type of feature afforded auxiliaries vital to the operation of propelling equipment, where automatic restart after a voltage failure would not create a hazard, is termed _____________. A. low voltage protection B. high amperage protection C. low voltage release D. high amperage release

Last Answer : Answer: C

Description : Grounds occurring in electrical machinery as a result of insulation failure may result from _____________. A. deterioration through extended use B. excessive heat C. extended periods of vibration D. all of the above

Last Answer : Answer: D

Description : What can be the reasons for the failure of the transformer?

Last Answer : Answer: Transformer is one of the most expensive equipments in the Power System. Failure of the transformer can cause outage of power supply for even days. However, multiple things can go wrong with ... relays. 3.Short Circuits 4.Open Circuits 5.Earth Faults 6.Over Voltage 7.Reduced system frequency

Description : What FCN was implemented to avoid reactor trip on 220V-DC failure of PHT and PPP breakers?

Last Answer : The breaker close position supervision relay VAA 21 is changed by VAJC type, contacts position do not change if 220V-DC is lost now.

Description : Why AVR changes over to manual on AVR PT fuse failure? 

Last Answer : Because loss of feedback to voltage corrector.  

Description : What is the cooling water used in moderator heat exchanger during normal operation? And during class IV failure?

Last Answer : During normal operation process LP water is used in moderator heat exchangers, which transfers heat to seawater. During class IV failure firewater is used for the moderator heat exchanger. 

Description : What causes RAM failure in the laptop?

Last Answer : There could be many different causes, including an awful power supply, unnecessary hotness, a PC infection/malware, an undermined working framework establishment or another flawed equipment component.

Description : What are the causes of display failure on a laptop?

Last Answer : Moisture which causes corrosion. Heat causing backlight failure. Pressure causing screen issues. Poor interconnects at the edge of the screen. Rugged handling dropping or jarring. Over extension of hinges or over use ... A single one of these or a combination of things will do it. Hope this helps.

Description : What causes laptop battery failure?

Last Answer : First rule out charging cord issues. Next Review your software options. If your battery not charging,chances are you have a faulty battery. One of the most common reasons a battery may not charge is its health.

Description : Assertion : The failure of secretion of hormone vasopressin causes diabetes mellitus in the patient. Reason : Vasopression reduces the volume of urine

Last Answer : Assertion : The failure of secretion of hormone vasopressin causes diabetes mellitus in the patient. ... . If both Assertion and Reason are false.

Description : What are the Causes of cardiac failure?

Last Answer : Feel Free to Answer

Description : The 7 Most Common Causes of Heart Failure?

Last Answer : Several factors have been identified that make a person moresusceptible to succumbing to heart failure, which is that conditionwhere the heart is either structurally or functionally compromisedto such ... can diminish due to a widevariety of reasons including, for instance, coronary arterydisease

Description : What are the causes of congestive heart failure in a patient?

Last Answer : Major causes of congested heart failure are smoking, environment, genetics, and lifestyle. Also lack of diet and exercise help contribute to heart problems.

Description : What are the causes of failure of superheater tubes ?

Last Answer : Superheater tubes are subjected to the most severe combination of stress, temperature and corrosive environment. In addition to high-temperature strength, resistance to corrosion is also important. For example, ... of the tube metal (e) Gas-side corrosion (f) Stress corrosion (austenitic steels).

Description : What are the causes of failure of boiler tubes ?

Last Answer : Boiler tubes, usually are made from carbon steel and are subject to (a) high rates of heat transfer,( b ). bending stresses due to uneven heating, especially at expanded or welded joints into ... and flue gas, (d) possible corrosion on the boiler side, and (e) occasional manufacturing defects.

Description : Select the correct statement with respect to disorders of muscles in humans. (a) Failure of neuromuscular transmission in myasthenia gravis can prevent normal swallowing. (b) Accumulation of ... of vitamin D causes osteoporosis. (d) Rapid contractions of skeletal muscles cause muscle dystrophy

Last Answer : (a) Failure of neuromuscular transmission in myasthenia gravis can prevent normal swallowing.

Description : Which of the following mitral valve conditions generally produces no symptoms? a) Prolapse Mitral valve prolpase is a deformity that usually produces no symptoms and has been diagnosed more ... ) Infection Mitral valve infection, when acute, will produce symptoms typical of infective endocarditis.

Last Answer : a) Prolapse Mitral valve prolpase is a deformity that usually produces no symptoms and has been diagnosed more frequently in recent years, probably as a result of improved diagnostic methods.

Description : What are the basic causes of the problem of rotor failure?

Last Answer : 1. Normal wear. 2. Fatigue failure due to high stress. 3. Design deficiency. 4. Aggressive operating environment

Description : What are four main causes of tape failure?

Last Answer : Normal wear, accidental damage, environmental damage, and winding errors.

Description : What criteria determine which engine is the critical engine of a twin-engine aeroplane? a. The one with the center of thrust farthest from the centreline of the fuselage b. The one ... the manufacturer which develops most usable thrust d. The failure of which causes the least yawing moment

Last Answer : b. The one with the center of thrust closest to the centreline of the fuselage

Description : Select the diuretic which is orally active, efficacious in acidosis as well as alkalosis, causes diuresis even in renal failure and has additional carbonic anhydrase inhibitory action: A. Mannitol B. Benzthiazide C. Indapamide D. Furosemide

Last Answer : D. Furosemide

Description : Discuss the causes of failure in flexible and rigid pavement.

Last Answer : Causes of failure in flexible pavement: The following are the causes of failure in flexible pavement: 1) Ineffective road surface drainage system such as, (i) inadequate cross slope of the ... joints or even non-uniform settlement of the pavement slabs resulting in deterioration in riding quality. 

Description : State any four causes of failure of rigid pavement

Last Answer : 1) Defective drainage system may lead to failures in rigid pavements such as mud pumping 2) Use of nondurable materials which start deteriorating during weathering cycles. 3) Improper alignment ... foundation itself, which could result in settlement of the supporting layers of the rigid pavement

Description : Which one of the following statements is incorrect ? (A) Pareto analysis is a statistical method used for analyzing causes, and is one of the primary tools for quality management. (B) Reliability of ... (D) In white-box testing, the test cases are decided from the specifications or the requirements.

Last Answer : (D) In white-box testing, the test cases are decided from the specifications or the requirements.

Description : State the causes for dielectric failure of highly purified transformer oil. 

Last Answer : The causes for dielectric failure of highly purified transformer oil:  1. Voltage rating 2. Humidity in atmosphere 3. Temperature of the oil 4. Due to improper cable joints and connection. 5. Increasing in supply frequency. 6. Due to unbalanced load. 

Description : State the causes of failure of heating element.

Last Answer : Following of the different causes of failure of heating element:  i) Formation of hot spot: Hot spot on heating element is the point which is at higher temperature than remaining heating element ... & cooling of heating element, it may break (fail) due to small mechanical injury also.

Description : What causes stator failure?

Last Answer : Stator faliur due to moistur. Due to priodically heatup of winding.