Steam condensate is recovered by steam traps and recycled for use as

boiler feed water, because of its low

(A) Hardness

(B) Dissolved solids content

(C) Suspended solids content

(D) All (A), (B) and (C)

1 Answer

Answer :

(D) All (A), (B) and (C)

Related questions

Description : A device known as a _______ is used to release condensate from the pipework whilst preventing the steam from escaping from the system. a. Steam traps b. Steam pipes c. Boiler nose d. Release valve

Last Answer : a. Steam traps

Description : Pick out the wrong statement. (A) Caustic embrittlement of boiler's metallic parts is caused by highconcentration of caustic soda in boiler feed water (B) Cooling and freezing of water kills the ... goes on decreasing (D) Dissolved oxygen content in high pressure boiler feed water should be nil

Last Answer : (B) Cooling and freezing of water kills the bacteria present in it

Description : Which of the following impurities in feed water for high pressure boiler is the most detrimental? (A) Silica (B) Dissolved oxygen (C) Suspended salt (D) Dissolved salt

Last Answer : (A) Silica

Description : The most detrimental impurity in high pressure boiler feed water is (A) Suspended salt (B) Dissolved salt (C) Silica (D) Turbidity

Last Answer : Option C

Description : Steam traps are provided in steam carrying pipelines to (A) Condense steam (B) Release excess steam pressure by bleeding steam (C) Remove condensate and inert gases (D) None of these

Last Answer : (C) Remove condensate and inert gases

Description : The term _________ is traditionally used to describe steam issuing from condensate receiver vents and openended condensate discharge lines from steam traps.  a. dry steam  b. wet steam  c. phase steam  d. flash steam

Last Answer : flash steam

Description : Deaeration of high pressure boiler feed water is done to reduce (A) Foaming from boilers (B) Its dissolved oxygen content (C) Its silica content (D) Caustic embrittlement

Last Answer : (B) Its dissolved oxygen content

Description : The temperature of boiling water in a steam engine may be high because - (1) there are dissolved substances in water (2) there is low pressure inside the boiler (3) there is high pressure inside the boiler (4) the lire is at very high temperature

Last Answer : (3) there is high pressure inside the boiler Explanation: In the boiler of a steam engine, there is a firebox where coal is shoveled into. The coal is kept burning at a very high temperature, and ... reservoir; the steam is then controlled by a slide valve to move into a cylinder to push the piston.

Description : The temperature of boiling water in a steam engine may be high because : (1) there are dissolved substances in water (2) there is low pressure inside the boiler (3) there is high pressure inside the boiler (4) the fire is at very high temperature

Last Answer :  there is high pressure inside the boiler

Description : Corrosiveness of steam condensate is due to the presence of (A) CO2 (B) Dissolved O2 (C) Both (A) & (B) (D) Neither (A) nor (B)

Last Answer : (C) Both (A) & (B)

Description : Turbidity of water is an indication of the presence of (A) Suspended inorganic matter (B) Dissolved solids (C) Floating solids (D) Dissolved gases

Last Answer : (A) Suspended inorganic matter

Description : Removal of __________ is accomplished by aeration of water. (A) Dissolved gases (B) Suspended solids (C) Dissolved solids (D) None of these

Last Answer : (A) Dissolved gases

Description : A __________ is a type of heat exchange system where water is heated to its' boiling point via combustion of a fuel blown through a tube submerged in water. a. Condensate loop b. Hyperbolic cooling tower c. Steam boiler d. All of above

Last Answer : c. Steam boiler

Description : Tri-sodium phosphate is used in boiler water treatment to reduce (A) Turbidity (B) Caustic embrittlement (C) Suspended silica (D) Dissolved oxygen

Last Answer : (B) Caustic embrittlement

Description : Chlorination of water is done for the removal of A. Bacterias B. Suspended solids C. Sediments D. Hardness

Last Answer : ANS: A

Description : In domestic sewage, suspended solids, colloidal and dissolved materials constitute

Last Answer : In domestic sewage, suspended solids, colloidal and dissolved materials constitute A. 0.1 B. 0.056 C. 0.027 D. 0.001

Description : Imhoff cone is used to determine A. Settleable solids B. Suspended solids C. Dissolved solids D. None of these

Last Answer : ANS: A

Description : The effluent of a septic tank is A. Fit for discharge into any open drain B. Foul and contains dissolved and suspended solids C. As good as that from a complete treatment D. None of these

Last Answer : ANS: A

Description : The domestic sewage in large cities (a) has a high BOD as it contains both aerobic and anaerobic bacteria (b) is processed by aerobic and then anaerobic bacteria in the secondary treatment in ... sewage contains adequate oxygen (d) has very high amount of suspended solids and dissolved salts.

Last Answer : (b) is processed by aerobic and then anaerobic bacteria in the secondary treatment in Sewage Treatment Plants (STPs)

Description : Foaming and priming in boiler operation can be reduced by reduction in __________ in feed water. (A) Turbidity (B) Color (Hazen) (C) Total solids (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : Scale formation in boiler is controlled by (A) Preheating of feed water (B) Reduction in hardness, silica & alumina in feed water (C) Keeping the pH value of feed water just below 7 (D) Eliminating H2S in feed water

Last Answer : (B) Reduction in hardness, silica & alumina in feed water

Description : . Presence of iron and manganese in water causes (A) Reduction in its dissolved oxygen content (B) Discoloration of bathroom fixtures (C) Temporary hardness (D) None of these

Last Answer : (B) Discoloration of bathroom fixtures

Description : In a gas-liquid shell and tube heat exchanger, the (A) Presence of a non-condensable gas decreases the condensing film co￾efficient (B) Gases under high pressure are routed through the tube side, because high pressure ... water or steam condensate remain localised to the tubes (D) All 'a', 'b' & 'c'

Last Answer : (D) All 'a', 'b' & 'c'

Description : The function of sedimentation tank in sewage treatment is to: (1) Disinfect the sewage (2) Remove water content (3) Aerate the sewage (4) Remove suspended solids

Last Answer : (4) Remove suspended solids Explanation: The function of sedimentation tank in the sewage treatment is to remove suspended solids.

Description : The function of sedimentation tank in sewage treatment is to: (1) Disinfect the sewage (2) Remove water content (3) Aerate the sewage (4) Remove suspended solids

Last Answer : Remove suspended solids

Description : The most prominent single cause of corrosion in boiler-tubes, drums, economisers and steam superheaters in a thermal power plant boiler is the (A) Water alkalinity & leakage (B) Hydrazine addition during ... treatment (C) Release of non-condensable gas from water in the boiler (D) Scale formation

Last Answer : (C) Release of non-condensable gas from water in the boiler

Description : The delivery pressure of boiler feed water pump compared to the boiler steam pressure is (A) Same (B) Slightly less (C) Slightly more (D) Much more

Last Answer : (C) Slightly more

Description : Pick out the wrong statement. (A) Recycled coarse material to the grinder by a classifier is termed as circulating load (B) Wear and tear in wet crushing is more than that in dry crushing of ... a pipeline which permits the solids to settle down due to reduction in velocity of the dust laden gas

Last Answer : (C) Size enlargement (opposite of size reduction) is not a mechanical operation

Description : Water that is fed back to the boiler by the pump is called? a. Absorber b. Absolute c. Compressor d. Condensate

Last Answer : d. Condensate

Description : Where is water steam separator drum located in Lamont boiler ? a. Inside of the boiler b. Right above the furnace c. Before the feed water pump d. Outside the boiler

Last Answer : d. Outside the boiler

Description : Through what is feed water from hot-well is passed through, before entering steam and water drum in Lamont boiler? a. Evaporator tubes b. Economizer c. Distributor header d. Circulating pump

Last Answer : b. Economizer

Description : In Drum type Boiler Feed water flow control by Three element controller a. Drum level b. Steam Flow c. Feed water flow d. All of above

Last Answer : Ans:- d. All of above

Description : Once the condensate reaches the _____ , it becomes available to the boiler for recycling. • Condenser • Turbine • Boiler • Generator

Last Answer : • Boiler

Description : Specific weight of sea water is more that of pure water because it contains (A) Dissolved air (B) Dissolved salt (C) Suspended matter (D) All of the above

Last Answer : Answer: Option D

Description : Condensing film co-efficient for steam on horizontal tubes ranges from 5000 to 15000 Kcal/hr.m2 .°C. Condensation of vapor is carried out inside the tube in a shell and tube heat ... drop through the exchanger is desired (D) Temperature of the incoming vapor is very high

Last Answer : (B) Supersaturated

Description : The steam ejector is used to (A) Remove condensate from the steam pipelines (B) Create vacuum (C) Superheat the steam (D) None of these

Last Answer : (B) Create vacuum

Description : A process stream of dilute aqueous solution flowing at the rate of10 Kg.s -1 is to be heated. Steam condensate at 95°C is available for heating purpose, also at a rate of 10 Kg.s -1 . A 1 ... side (C) Parallel flow with process stream on shell side (D) Parallel flow with process stream on tube side

Last Answer : (A) Counter flow with process stream on shell side

Description : Trap is used to remove __________ from steam pipe lines. (A) Steam (B) Condensate (C) Non-condensable (D) None of these

Last Answer : (B) Condensate

Description : In a Rankine cycle, regeneration results in higher efficiency because (a) Pressure inside the boiler increases [GATE-2003] (b) Heat is added before steam enters the low pressure turbine (c) ... temperature of heat addition in the boiler increases (d) Total work delivered by the turbine increases 

Last Answer : (c) Average temperature of heat addition in the boiler increases  

Description : Presence of __________ in water stream are deleterious to aquatic life. (A) Soluble and toxic organics (B) Suspended solids (C) Heavy metals and cyanides (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : Coal washing waste water containing about 3% suspended solids (comprising of clay, slate, stone etc.) is treated for solid particles removal (A) By chemical coagulation (B) In sedimentation tanks equipped with mechanical scrapper (C) In vacuum filter (D) In clarifiers

Last Answer : (B) In sedimentation tanks equipped with mechanical scrapper

Description : Which of the following is the most lethal water pollutant? (A) Phenol and cyanide (B) Chlorine (C) Alkalis (D) Suspended solids

Last Answer : (A) Phenol and cyanide

Description : Lagoons used for purification of polluted water (A) Are large shallow artificial lakes also known as clarification lakes, maturation ponds or oxidation ponds (B) Use micro-organisms/bacteria in presence of dissolved oxygen (C) Gives an ... 1 mg/litre and BOD = 3.8 mg/litre (D) All (A), (B) & (C)

Last Answer : (D) All (A), (B) & (C)

Description : Tabular bowl centrifuges as compared to disk bowl centrifuges (A) Operate at higher speed (B) Employ bowl of larger diameter (C) Can’t be operated under pressure/vacuum (D) Can’t be used for separation of fine suspended solids from a liquid

Last Answer : (A) Operate at higher speed

Description : Which of the following is the most suitable filter for separation ofabrasive solids suspended in a corrosive liquid? (A) Sand bed filter (B) Plate and frame filter press (C) Vacuum filter (D) Batch basket centrifuge

Last Answer : (C) Vacuum filter

Description : A packed tower compared to a plate tower for a particular mass transfer operation (A) Incurs smaller pressure drop (B) Allows installation of cooling coils (C) Is less costly when built in large sizes/diameters (D) Is more suitable, if suspended solids are present in fluid stream

Last Answer : (A) Incurs smaller pressure drop

Description : Which of the following is the most efficient for removal of very finely divided suspended solids and colloidal matter from the polluted waterstream? (A) Sedimentation tank (B) Circular clarifier (C) Mechanical flocculation (D) Chemical coagulation

Last Answer : (D) Chemical coagulation

Description : The _______ system includes anywhere that the steam condenses to form liquid water. a. Loop b. Power c. Liquid d. Condensate

Last Answer : d. Condensate

Description : The function of skimming tank in sewage treatment is to remove __________ substances. (A) Dissolved solid (B) Suspended solid (C) Oil & fatty (D) Gritty & inorganic

Last Answer : (C) Oil & fatty

Description : The resistance of water to the passage of light through it is a measure of the (A) Turbidity (B) Color (C) Hardness (D) Dissolved gases

Last Answer : (A) Turbidity