As the reflux ratio decreases, the
(A) Separation becomes more efficient
(B) Number of plates increases
(C) Column diameter increases
(D) None of these

1 Answer

Answer :

(B) Number of plates increases

Related questions

Description : As the reflux ratio in a distillation column is increased from the minimum, the (A) Slope of the operating line in stripping section decreases (B) Number of plates decreases very slowly first ... decreases and then increases (D) Liquid flow increases while the vapor flow decreases for a system

Last Answer : (C) Total cost first decreases and then increases

Description : Pick out the correct statement. (A) The slope of the stripping line is always less than unity (B) For a given separation in a binary distillation column, with increase in reflux ratio ( ... (D) Kremser-Brown-Souder's equation is used to calculate the efficiency of a plate tower

Last Answer : C) In Ponchon-Savarit method of no. of theoretical plate determination, the stripping and rectifying operating lines are vertical at total reflux

Description : The minimum number of theoretical plates is required for achieving a given separation in distillation column with (A) No reflux (B) Total reflux (C) Zero reflux ratio (D) Minimum reflux ratio

Last Answer : (B) Total reflux

Description : At minimum reflux ratio for a given separation (A) Number of plates is zero (B) Number of plates is infinity (C) Minimum number of the theoretical plates is required (D) Separation is most efficient

Last Answer : (B) Number of plates is infinity

Description : Pick out the wrong statement: (A) Reboiler is not used in open steam distillation (B) The separation of solutes of different molecular sizes in a liquid solution by use of a ... is used for calculating theoretical number of plates in a distillation column at normal operating reflux condition

Last Answer : (D) Fenske-Underwood equation is used for calculating theoretical number of plates in a distillation column at normal operating reflux condition

Description : For a fixed number of ideal stages in a distillation column, as the reflux ratio is increased, the difference in composition between the top and bottom product streams (A) Increases (B) Decreases (C) Remain unaffected (D) Passes through a maximum

Last Answer : (A) Increases

Description : For the same process conditions, the reflux ratio of an unlagged distillation column (A) Decreases in winter (B) Increases in winter (C) Increases in summer (D) None of these

Last Answer : (B) Increases in winter

Description : . In a distillation column, with increase in the reflux ratio, the heat removed in the cooler (A) Increases (B) Decreases (C) Remains unaffected (D) And the heat required in reboiler decreases

Last Answer : (A) Increases

Description : The feed to fractionating column is changed from saturated vapour to saturated liquid. If the separation and reflux ratio remains unchanged, the number of ideal stages will (A) Increase (B) Decrease (C) Remain same (D) Depend on saturated boiling point; may increase or decrease

Last Answer : (A) Increase

Description : Fenske equation determines the (A) Maximum number of ideal plates (B) Height of the distillation column (C) Minimum number of theoretical plates (D) Optimum reflux ratio

Last Answer : (C) Minimum number of theoretical plates

Description : At what value of reflux ratio, number of theoretical plates in a distillation column is minimum? (A) 0 (B) 1 (C) ∞ (D) < 1

Last Answer : (C) ∞

Description : For a distillation column operating at minimum reflux, the (A) Concentration of liquid and vapour leaving a plate will be same (B) Reflux ratio will be maximum (C) Number of plates required will be maximum

Last Answer : (C) Number of plates required will be maximum

Description : Pick out the wrong statement. (A) In solvent extraction, the distribution co-efficient should be as large as possible for solvent economy (B) With increase in pressure, the solubility of ... in distillation column (D) The capacity of a distillation column is maximum at total reflux

Last Answer : (D) The capacity of a distillation column is maximum at total reflux

Description : Pick out the correct statement. (A) Higher hold up of the solid in the rotary dryer results in better exposure of the solids to the gas (B) The 'Hatta number' is ... reflux in case of distillation operation requires infinite number of plates for a binary system separation

Last Answer : (C) For a non-reacting binary mixture of ideal gases, the partial pressure distribution of both components is linear in the case of steady state equimolal counter-diffusion

Description : Fenske-Underwood equation used for calculating the minimum number of theoretical plates in distillation column is valid for (A) Constant molal overflow (B) Total reflux (C) Constant relative volatility (D) All (A), (B) and (C)

Last Answer : (D) All (A), (B) and (C)

Description : Pick out the wrong statement. (A) With decrease in feed temperature, the number of plates required for binary distillation decreases for a given L/V' ratio (B) The extraction per unit ... and its cross￾section is wider at the bottom (D) Vander wall adsorption is also called chemisorption

Last Answer : (D) Vander wall adsorption is also called chemisorption

Description : A distillation column with N plates is being operated under normal conditions. At some point of time, the operation is shifted to total reflux condition (i.e., no product and residue are ... and without total reflux (D) The top and bottom compositions correspond to the maximum enrichment available

Last Answer : (D) The top and bottom compositions correspond to the maximum enrichment available

Description : . For the same feed, feed quality and separation (in a distillation column), with the increase of total pressure, the number of ideal plates will (A) Increase (B) Decrease (C) Remain same (D) Data insufficient, can't be predicted

Last Answer : (A) Increase

Description : To improve a chromatographic separation, you must A. Increase the number of theoretical plates on the column. B. Increase the height of the theoretical plates on the column. C. Increase both the number ... the column. D. Decrease both the number and the height of the theoretical plates on the column

Last Answer : Increase the number of theoretical plates on the column

Description : In McCabe-Thiele method, at infinite reflux ratio (A) Number of plates is maximum (B) Overhead product is maximum (C) Both the operating lines coincide with the diagram (D) None of these

Last Answer : (C) Both the operating lines coincide with the diagram

Description : Can the efficiency of a plate in the distillation tower be greater than 100%? (A) Yes (B) Normally not; but is possible if infinite number of plates are put (C) Never (D) Yes; if the reflux ratio is maximum

Last Answer : (C) Never

Description : For a binary mixture with low relative volatility, continuous rectification to get pure products will require (A) Low reflux ratio (B) Less number of trays (C) Small cross-section column (D) High reflux ratio

Last Answer : (D) High reflux ratio

Description : Minimum reflux ratio in a distillation column results in (A) Optimum number of trays (B) Minimum reboiler size (C) Maximum condenser size (D) Minimum number of trays

Last Answer : (C) Maximum condenser size

Description : In batch distillation with constant reflux, overhead product composition __________ with time. (A) Increases (B) Decreases (C) Does not vary (D) May increase on decrease, depends on the system

Last Answer : (B) Decreases

Description : With lapse of time, the overhead composition of light component in case of batch distillation with constant reflux (A) Increases (B) Decreases (C) Remain same (D) May increase or decrease; depends on system

Last Answer : (B) Decreases

Description : Pick out the wrong statement. (A) Different solids have different equilibrium moisture curves (B) Total condenser or reboiler is considered equivalent to one theoretical plate in McCabe-Thiele method of ... (D) Even a forced draft cooling tower cannot cool water below the wet bulb temperature

Last Answer : (C) Heat removal load on cooler remains constant, even with increase of the reflux ratio in a distillation column

Description : The reflux to a distillation column is 100 moles/hr, when the overhead product rate is 50 moles/hr. The reflux ratio is (A) 2 (B) 0.5 (C) 50 (D) 150

Last Answer : (A) 2

Description : The operating cost of a distillation column at minimum reflux ratio is (A) Minimum (B) Maximum (C) Infinite (D) Zero

Last Answer : (A) Minimum

Description : Overall efficiency of the distillation column is (A) The ratio of number of ideal plates to actual plates (B) The ratio of number of actual plates to ideal plates (C) Same as the Murphree efficiency (D) Always more than the point efficiency

Last Answer : (A) The ratio of number of ideal plates to actual plates

Description : With increase in the ratio of orifice diameter to pipe diameter, the fraction of the orifice pressure differential that is permanently lost (A) Increases (B) Decreases (C) Remains unchanged (D) Increases exponentially

Last Answer : (B) Decreases

Description : With increase in the ratio of orifice diameter to pipe diameter in case of an orificemeter, the overall pressure loss (A) Decreases (B) Increases (C) Remain constant (D) Increases linearly

Last Answer : (C) Remain constant

Description : Pick out the wrong statement. (A) In a first order reaction, A → products; the reaction becomes slower as it proceeds, because the concentration of A decreases and the rate is proportional to the concentration ... irreversible reaction, A + B → 2C is k.CA .CB , then the reaction is always elementary

Last Answer : (C) According to the penetration theory, the mass transfer co-efficient decreases, if the exposure time of an eddy to the solute decreases

Description : Tower diameter may be decreased by (A) Using higher reflux ratio (B) Use of increased tray spacing (C) Increasing the liquid flow rate (D) Increasing the vapour flow rate

Last Answer : (B) Use of increased tray spacing

Description : Total reflux in a distillation operation requires minimum (A) Reboiler load (B) Number of plates (C) Condenser load (D) All (A), (B) and (C)

Last Answer : (B) Number of plates

Description : At __________ reflux, theoretical number of plates in a distillation coloumn is calculated using Fenske-Underwood equation. (A) Operating (B) Total (C) Minimum (D) Maximum permissible

Last Answer : (B) Total

Description : Steam distillation is used to (A) Reduce the number of plates (B) Avoid thermal decomposition of a component (C) Increase the efficiency of separation (D) Increase the total pressure of distillation

Last Answer : (B) Avoid thermal decomposition of a component

Description : Increasing concave length_______ seed separation at diminishing rate a) Increases b) Decreases c)No effect d) None of the

Last Answer : a) Increases

Description : Which of the following activities occurs during the charging process of a lead-acid storage battery? A. The specific gravity of the acid increases. B. Both plates change chemically to lead sulfate. C. The specific gravity of the acid decreases. D. Hydrogen gas is absorbed.

Last Answer : Answer: A

Description : As the product becomes finer, the energy required for grinding (A) Decreases (B) Increases (C) Is same as for coarser grinding (D) Is 1.5 times that for coarser grinding

Last Answer : (B) Increases

Description : With increase in temperature, the thermal conductivity of most liquids (A) Increases (B) Decreases (C) Remain same (D) First increases upto a certain temperature and then becomes constant

Last Answer : (C) Remain same

Description : During ageing of fluid carrying pipes, the (A) Pipe becomes smoother with use (B) Friction factor increases linearly with time (C) Absolute roughness decreases with time (D) Absolute roughness increases linearly with time

Last Answer : (D) Absolute roughness increases linearly with time

Description : When a catalyst increases the rate of forward reaction, the value of rate constant (A) Increases (B) Decreases (C) Remain same (D) Becomes infinite

Last Answer : (A) Increases

Description : Back-trapping in a distillation column (A) Increases tray efficiency (B) Decreases tray efficiency (C) Reduces pressure drop (D) Is desirable, as it provides improved vapour-liquid contact

Last Answer : (B) Decreases tray efficiency

Description : With increase in the liquid flow rate at a fixed gas velocity in a randomly packed counter current gas-liquid absorption column, the gas pressure drop (A) Decreases (B) Remains unchanged (C) Increases (D) Decreases exponentially

Last Answer : (C) Increases

Description : In the illustrated circuit, one advantage of the capacitor coupling over direct coupling is ____________. EL-0048 A. as the frequency decreased the capacitive reactance (Xc) increases B. the amplifier becomes ... of the signal while it isolates the biasing of each stage. D. good frequency response.

Last Answer : Answer: C

Description : In case of vertical tube evaporator, with increase in liquor level, the overall heat transfer co-efficient (A) Increases (B) Decreases (C) Is not affected (D) May increase or decrease; depends on the feed

Last Answer : (B) Decreases

Description : Presence of a non-condensing gas in a condensing vapour (A) Increases the rate of condensation (B) Decreases thermal resistance (C) Is desirable to increase the film co-efficient (D) None of these

Last Answer : (D) None of these

Description : Free energy, fugacity and activity co-efficient are all affected by change in the temperature. The fugacity co-efficient of a gas at constant pressure ____with the increase of reduced temperature. (A) Decreases (B) Increases (C) Remains constant

Last Answer : (B) Increases

Description : With increase in reduced temperature, the fugacity co-efficient of a gas at constant reduced pressure (A) Increases (B) Decreases (C) Remain same (D) Decreases linearly

Last Answer : (A) Increases