For the measurement of temperature of the order of 400°C, what will we
prefer?

1 Answer

Answer :

Thermocouple

Related questions

Description : Combustion of furnace oil in a furnace (soaking pit) with preheated combustion air at 400°C results in saving of about __________ percentfurnace oil as compared to its combustion with atmospheric air, if the flue gas outlet temperature from the soaking pit is 1200°C. (A) 5 (B) 60 (C) 20 (D) 40

Last Answer : (C) 20

Description : Temperature and pressure in urea autoclave is (A) 120°C and 300 atm (B) 190°C and 200 atm (C) 400°C and 550 atm (D) 200°C and 10 atm

Last Answer : (B) 190°C and 200 atm

Description : Pick up the correct statement from the following: (A) Solder material is an alloy which melts at a temperature above 400°C (B) Brazing is done at temperature above 600°C to 1100°C (C) Brazing joint is stronger than the solder joint (D) All the above

Last Answer : Answer: Option D

Description : (4) Decomposition of manganese dioxide Explanation: One of the two chemical methods starts from natural manganese dioxide and converts it using dinitrogen tetroxide and water to manganese nitrate ... 400°C, the salt decomposes, releasing N2O4 and leaving a residue of purified manganese dioxide.

Last Answer : The mass number of a nucleus is - (1) always less than its atomic number (2) the sum of the number of protons and neutrons present in the nucleus (3) always more than the atomic weight (4) a fraction

Description : Hardening is a process of heating a metal to a) 400°C b) 500°C c) 600°C d) 700°C

Last Answer : c) 600°C

Description : Which of the following will be unsuitable for dust cleaning from flue gas at 400°C from a pulverised coal fired boiler? (A) Multicyclones (B) Bag filter (C) Wet scrubber (D) Hydrocyclones

Last Answer : (B) Bag filter

Description : Furan reacts with ammonia in the presence of alumina at 400°C to give (a) Pyridine (b) Furfural (c) Pyrrole (d) Furoic acid

Last Answer : Pyrrole

Description : When propyne is passed through hot iron tube at 400°C, it gives (a) Benzene (b) Toluene (c) m-Xylene (d) Mesitylene

Last Answer : Mesitylene

Description : When acetylene is passed through hot iron tube at 400°C, it gives (a) Benzene (b) Toluene (c) o-Xylene (d) Mesitylene

Last Answer : Benzene

Description : Steam undergoes isentropic expansion in a turbine from 5000 kPa and 400°C (entropy = 6.65 kJ/kg K) to 150 kPa) (entropy of saturated liquid = 1.4336 kJ/kg. K, entropy of saturated vapour = 7.2234 ... vapour with quality of 0.9 (C) Saturated vapour (D) Partially condensed vapour with quality of 0.1

Last Answer : (A) Superheated vapour

Description : Why do we prefix "degree" in temperature measurement scales?

Last Answer : We not only need the name of the reference scale, but to know the measurement units of that scale. There are many redundancies in the English language. Some have been dropped, and others ... measurement unit nor measurement scale. So sometimes the redundancies do get dropped, and other times not.

Description : How can we ensure the better temperature measurement on the stainless steel microtube?

Last Answer : The temperature of a stainless steel microtube is checked by using a thermocouple.

Description : In order to increase its range of measurement, a resistance would be placed in series with which of the following instruments? A. DC voltmeter B. DC ammeter C. frequency meter D. power factor meter

Last Answer : Answer: A

Description : According to ISI method of measurement, the order of the sequence is (A) Length, breadth, height (B) Breadth, length, height (C) Height, length, breadth (D) None of these

Last Answer : (A) Length, breadth, height

Description : In order to make an accurate measurement as possible, the internal resistance of a voltmeter must be

Last Answer : as high as possible

Description : Which of the following is the correct order of Stevens’ four levels of measurement? a. Ordinal, nominal, ratio, interval b. Nominal, ordinal, interval, ratio c. Interval, nominal, ordinal, ratio d. Ratio, interval, nominal, ordinal

Last Answer : b. Nominal, ordinal, interval, ratio

Description : An ordinal scale is: a. The simplest form of measurement b. A rank-order scale of measurement c. A scale with equal intervals between adjacent numbers d. A scale with an absolute zero point e. A categorical scale

Last Answer : b. A rank-order scale of measurement

Description : Any person, aggrieved by an order of made by the national commission may prefer  an appeal against such order within thirty days to a) An appeal shall not be made against National commission b) The ... National commission is final c) An appeal shall be made to Supreme court d) Above A&B only

Last Answer : c) An appeal shall be made to Supreme court

Description : Any person aggrieved by an order made by the State commission may prefer an  appeal such order to the National commission within a) 60 days b) 90 days c) 1 month d) Thirty days

Last Answer : d) Thirty days

Description : Any person aggrieved by an order made by the District forum may prefer an appeal  such order to the State commission within a) 60 days b) 90 days c) 1 month d) Thirty days

Last Answer : d) Thirty days

Description : The temperature of a liquid can be measured in Kelvin units as x K or in Fahrenheit units as y°F. The relation between the two system of measurement of temperature is given by the linear equation y = 9/5 ( x - 273 ) + 32 -Maths 9th

Last Answer : Solution :-

Description : Temperature measurement?

Last Answer : DefinitionTemperature measurement is a method to take a person's temperature and determine whether it is within a normal range. A high temperature is a fever.How the test is performedIn the past, a ... color to indicate the temperature. This method is the least accurate. Place the strip on the fore

Description : Vycor, a widely used material for making 'thermal wells' in temperature measurement, is a (A) Cermet (B) Glass (C) Thermosetting plastic (D) Metallic alloy

Last Answer : (B) Glass

Description : The high expansion metal normally used in the bimetallic thermometer is __________ temperature measurement. (A) Brass for low (B) Nickel alloys for high (C) Both 'a' & 'b' (D) Aluminium for all

Last Answer : (C) Both 'a' & 'b'

Description : Furnace aerodynamics is related to the __________ in the furnace. (A) Movement of gases (B) Measurement of flue gas volume (C) Temperature control

Last Answer : (A) Movement of gases

Description : Ringelmann chart is used for the measurement of the (A) Combustibles present in automobile exhaust (B) Smoke density from a chimney (C) Exhaust gas density (D) Flue gas temperature

Last Answer : (B) Smoke density from a chimney

Description : Measurement of thermodynamic property of temperature is facilitated by __________ law of thermodynamics. (A) 1st (B) Zeroth (C) 3rd (D) None of these

Last Answer : B) Zeroth

Description : Temperature of hot gases flowing in a pipe is measured by a thermocouple inserted in the thermal well. The thermal well made of __________ will facilitate the most accurate measurement of the temperature. (A) Copper (B) Steel (C) Aluminium (D) Brass

Last Answer : Option A

Description : Temperature of hot gases flowing in a pipe is measured by a thermocouple inserted in the thermal well. The thermal well made of __________ will facilitate the most accurate measurement of the temperature. (A) Copper (B) Steel (C) Aluminium (D) Brass

Last Answer : Option A

Description : is a non-contact type measurement which when directed at a heat source directly gives the temperature read out. a) Thermocouples. c) Contact thermometers. b) Humidity. d) Infrared thermometers

Last Answer : Infrared thermometers

Description : is a non-contact type measurement which when directed at a heat source directly gives the temperature read out. a) Thermocouples. b) Contact thermometers. c) Humidity. d) Infrared thermometers.

Last Answer :  Infrared thermometers.

Description : The measurement of a thermodynamic property known as temperature is based on  A. Zeroth law of thermodynamics  B. First law of thermodynamics  C. Second law of thermodynamics  D. none of these

Last Answer : Answer: A

Description : Measurement of temperature is based on  (a) thermodynamic properties  (b) zeroth law of thermodynamics  (c) first law of thermodynamics  (d) second law of thermodynamics  (e) joule’s law.

Last Answer : Answer : b

Description : When would you measure the minimum preheat temperature? a) On completion of each pass b) Immediately prior to commencing the first pass and subsequent passes c) When the welding is ... preheat temperature measurement is only required if the heat input is lower than that specified in WPS

Last Answer : b) Immediately prior to commencing the first pass and subsequent passes

Description : The calibration of an HPLC detector can be evaluated by measurement of? A. Retention time B. Temperature C. Flow rate accuracy D. Intensity of the peak

Last Answer : D. Intensity of the peak

Description : Thermocouples are used for the measurement of (A) humidity. (B) pressure. (C) temperature. (D) density.

Last Answer : (C) temperature.

Description : Explain the measurement of Retractive index and it’s dependence on composition and temperature.

Last Answer : Measurement of Refractive Index: The Refractive index of a medium is defined as the ratio of speed of lignt in vacuum to the speed of light in the medium  The refractive ... light through the liquid. Thus the refractive index of liquid or solution increases with increasing concentration. 

Description : Describe the instrumentation system used for temperature measurement using thermistor.

Last Answer : A thermistor is a type of resistor whose resistance is dependent on temperature. Thermistors are of two opposite fundamental types: With NTC, resistance Decreases with temperature to ... converted to Digital by ADC further given to multiplexer, then output is displayed on computer. 

Description : Draw and explain temperature measurement using RTD. State its advantages and disadvantages.

Last Answer : https://youtu.be/rYcglFW4y0I

Description : Which of the following transducers can be used for non-contact temperature measurement? A) Resistance temperature detector B) Thermistor C) Sensistor D) Pyrometer 

Last Answer : Which of the following transducers can be used for non-contact temperature measurement? A) Resistance temperature detector B) Thermistor C) Sensistor D) Pyrometer